Skip to main content
Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 2/2014

01.03.2014 | Original article

Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption

verfasst von: Dr. M. Nienkemper, B. Wilmes, A. Pauls, S. Yamaguchi, B. Ludwig, D. Drescher

Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

Objective

The aim of this study was to evaluate the efficiency of molar distalization depending on age and second-molar eruption using the Beneslider.

Materials and methods

Treatment of 51 patients (mean age 17.8 ± 9.6 years) was investigated retrospectively by means of pre- and posttreatment cephalograms. Patients were divided into three groups: 14 children with unerupted upper second molars (group 1), 23 adolescents with second molar in place (group 2), and 14 adults (group 3). The distalization forces applied were 2.4 N in group 1 and 5.0 N in groups 2 and 3. Treatment changes were evaluated and examined statistically for significant differences.

Results

In all patients a Class I molar relationship was achieved. All mini-implants remained stable during treatment. Mean distalization distance as measured by the displacement of the center of resistance was 3.6 ± 1.9 mm (range 1.2–8.5 mm depending on treatment needs). Since no significant tipping was detected, the type of movement can be described as bodily movement. Mean overall distalization speed was 0.6 ± 0.4 mm per month. There were no statistical differences between the groups.

Conclusion

We found the Beneslider to be an effective appliance that enables bodily distalization in adequate treatment time. The higher resistance due to erupted second molars can be compensated by the use of higher forces without significantly reducing distalization speed.
Literatur
1.
Zurück zum Zitat Antonarakis GS, Kiliaridis S (2008) Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review. Angle Orthod 78:1133–1140PubMedCrossRef Antonarakis GS, Kiliaridis S (2008) Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review. Angle Orthod 78:1133–1140PubMedCrossRef
2.
Zurück zum Zitat Bjork A, Skieller V (1983) Normal and abnormal growth of the mandible. A synthesis of longitudinal cephalometric implant studies over a period of 25 years. Eur J Orthod 5:1–46PubMedCrossRef Bjork A, Skieller V (1983) Normal and abnormal growth of the mandible. A synthesis of longitudinal cephalometric implant studies over a period of 25 years. Eur J Orthod 5:1–46PubMedCrossRef
3.
Zurück zum Zitat Bolla E, Muratore F, Carano A et al (2002) Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod 72:481–494PubMed Bolla E, Muratore F, Carano A et al (2002) Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod 72:481–494PubMed
4.
Zurück zum Zitat Bussick TJ, McNamara JA Jr (2000) Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop 117:333–343PubMedCrossRef Bussick TJ, McNamara JA Jr (2000) Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop 117:333–343PubMedCrossRef
5.
Zurück zum Zitat Byloff FK, Darendeliler MA (1997) Distal molar movement using the pendulum appliance. Part 1: clinical and radiological evaluation. Angle Orthod 67:249–260PubMed Byloff FK, Darendeliler MA (1997) Distal molar movement using the pendulum appliance. Part 1: clinical and radiological evaluation. Angle Orthod 67:249–260PubMed
6.
Zurück zum Zitat Byloff FK, Darendeliler MA, Clar E et al (1997) Distal molar movement using the pendulum appliance. Part 2: the effects of maxillary molar root uprighting bends. Angle Orthod 67:261–270PubMed Byloff FK, Darendeliler MA, Clar E et al (1997) Distal molar movement using the pendulum appliance. Part 2: the effects of maxillary molar root uprighting bends. Angle Orthod 67:261–270PubMed
7.
Zurück zum Zitat Carano A, Testa M (1996) The distal jet for upper molar distalization. J Clin Orthod 30:374–380PubMed Carano A, Testa M (1996) The distal jet for upper molar distalization. J Clin Orthod 30:374–380PubMed
8.
Zurück zum Zitat Chiu PP, McNamara JA Jr, Franchi L (2005) A comparison of two intraoral molar distalization appliances: distal jet versus pendulum. Am J Orthod Dentofacial Orthop 128:353–365PubMedCrossRef Chiu PP, McNamara JA Jr, Franchi L (2005) A comparison of two intraoral molar distalization appliances: distal jet versus pendulum. Am J Orthod Dentofacial Orthop 128:353–365PubMedCrossRef
9.
Zurück zum Zitat Cornelis MA, De Clerck HJ (2007) Maxillary molar distalization with miniplates assessed on digital models: a prospective clinical trial. Am J Orthod Dentofacial Orthop 132:373–377PubMedCrossRef Cornelis MA, De Clerck HJ (2007) Maxillary molar distalization with miniplates assessed on digital models: a prospective clinical trial. Am J Orthod Dentofacial Orthop 132:373–377PubMedCrossRef
10.
Zurück zum Zitat Dahlberg G (1940) statistical methods for medical and biological students. Intersience Publications, New York Dahlberg G (1940) statistical methods for medical and biological students. Intersience Publications, New York
11.
Zurück zum Zitat Escobar SA, Tellez PA, Moncada CA et al (2007) Distalization of maxillary molars with the bone-supported pendulum: a clinical study. Am J Orthod Dentofacial Orthop 131:545–549PubMedCrossRef Escobar SA, Tellez PA, Moncada CA et al (2007) Distalization of maxillary molars with the bone-supported pendulum: a clinical study. Am J Orthod Dentofacial Orthop 131:545–549PubMedCrossRef
12.
Zurück zum Zitat Fontana M, Cozzani M, Caprioglio A (2012) Soft tissue, skeletal and dentoalveolar changes following conventional anchorage molar distalization therapy in class II non-growing subjects: a multicentric retrospective study. Prog Orthod 13:30–41PubMedCrossRef Fontana M, Cozzani M, Caprioglio A (2012) Soft tissue, skeletal and dentoalveolar changes following conventional anchorage molar distalization therapy in class II non-growing subjects: a multicentric retrospective study. Prog Orthod 13:30–41PubMedCrossRef
13.
Zurück zum Zitat Fortini A, Lupoli M, Giuntoli F et al (2004) Dentoskeletal effects induced by rapid molar distalization with the first class appliance. Am J Orthod Dentofacial Orthop 125:697–704 (discussion 704–695)PubMedCrossRef Fortini A, Lupoli M, Giuntoli F et al (2004) Dentoskeletal effects induced by rapid molar distalization with the first class appliance. Am J Orthod Dentofacial Orthop 125:697–704 (discussion 704–695)PubMedCrossRef
14.
Zurück zum Zitat Fudalej P, Antoszewska J (2011) Are orthodontic distalizers reinforced with the temporary skeletal anchorage devices effective? Am J Orthod Dentofacial Orthop 139:722–729PubMedCrossRef Fudalej P, Antoszewska J (2011) Are orthodontic distalizers reinforced with the temporary skeletal anchorage devices effective? Am J Orthod Dentofacial Orthop 139:722–729PubMedCrossRef
15.
Zurück zum Zitat Fuziy A, Rodrigues de Almeida R, Janson G et al (2006) Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance. Am J Orthod Dentofacial Orthop 130:502–510PubMedCrossRef Fuziy A, Rodrigues de Almeida R, Janson G et al (2006) Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance. Am J Orthod Dentofacial Orthop 130:502–510PubMedCrossRef
16.
Zurück zum Zitat Gelgor IE, Karaman AI, Buyukyilmaz T (2007) Comparison of 2 distalization systems supported by intraosseous screws. Am J Orthod Dentofacial Orthop 131:161.e1–8PubMed Gelgor IE, Karaman AI, Buyukyilmaz T (2007) Comparison of 2 distalization systems supported by intraosseous screws. Am J Orthod Dentofacial Orthop 131:161.e1–8PubMed
17.
Zurück zum Zitat Ghosh J, Nanda RS (1996) Evaluation of an intraoral maxillary molar distalization technique. Am J Orthod Dentofacial Orthop 110:639–646PubMedCrossRef Ghosh J, Nanda RS (1996) Evaluation of an intraoral maxillary molar distalization technique. Am J Orthod Dentofacial Orthop 110:639–646PubMedCrossRef
18.
Zurück zum Zitat Godt A, Kalwitzki M, Goz G (2005) Retrospective analysis of casts to assess cervical headgear treatment in the presence of vertical growth pattern. J Orofac Orthop 66:230–240PubMedCrossRef Godt A, Kalwitzki M, Goz G (2005) Retrospective analysis of casts to assess cervical headgear treatment in the presence of vertical growth pattern. J Orofac Orthop 66:230–240PubMedCrossRef
19.
Zurück zum Zitat Graber T (1955) Extraoral force—facts and fallacies. Am L Orthod 41:490–505CrossRef Graber T (1955) Extraoral force—facts and fallacies. Am L Orthod 41:490–505CrossRef
20.
Zurück zum Zitat Hilgers JJ (1992) The pendulum appliance for Class II non-compliance therapy. J Clin Orthod 26:706–714PubMed Hilgers JJ (1992) The pendulum appliance for Class II non-compliance therapy. J Clin Orthod 26:706–714PubMed
21.
Zurück zum Zitat Houston WJ (1983) The analysis of errors in orthodontic measurements. Am J Orthod 83:382–390PubMedCrossRef Houston WJ (1983) The analysis of errors in orthodontic measurements. Am J Orthod 83:382–390PubMedCrossRef
22.
Zurück zum Zitat Jeckel N, Rakosi T (1991) Molar distalization by intra-oral force application. Eur J Orthod 13:43–46PubMedCrossRef Jeckel N, Rakosi T (1991) Molar distalization by intra-oral force application. Eur J Orthod 13:43–46PubMedCrossRef
23.
Zurück zum Zitat Kang S, Lee SJ, Ahn SJ et al (2007) Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop 131:S74–S81PubMedCrossRef Kang S, Lee SJ, Ahn SJ et al (2007) Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop 131:S74–S81PubMedCrossRef
24.
Zurück zum Zitat Kanomi R (1997) Mini-implant for orthodontic anchorage. J Clin Orthod 31:763–767PubMed Kanomi R (1997) Mini-implant for orthodontic anchorage. J Clin Orthod 31:763–767PubMed
25.
Zurück zum Zitat Karlsson I, Bondemark L (2006) Intraoral maxillary molar distalization. Angle Orthod 76:923–929PubMedCrossRef Karlsson I, Bondemark L (2006) Intraoral maxillary molar distalization. Angle Orthod 76:923–929PubMedCrossRef
26.
Zurück zum Zitat Keles A, Erverdi N, Sezen S (2003) Bodily distalization of molars with absolute anchorage. Angle Orthod 73:471–482PubMed Keles A, Erverdi N, Sezen S (2003) Bodily distalization of molars with absolute anchorage. Angle Orthod 73:471–482PubMed
27.
Zurück zum Zitat Keles A, Sayinsu K (2000) A new approach in maxillary molar distalization: intraoral bodily molar distalizer. Am J Orthod Dentofacial Orthop 117:39–48PubMedCrossRef Keles A, Sayinsu K (2000) A new approach in maxillary molar distalization: intraoral bodily molar distalizer. Am J Orthod Dentofacial Orthop 117:39–48PubMedCrossRef
28.
Zurück zum Zitat Kim HJ, Yun HS, Park HD et al (2006) Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop 130:177–182PubMedCrossRef Kim HJ, Yun HS, Park HD et al (2006) Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop 130:177–182PubMedCrossRef
29.
Zurück zum Zitat Kinzinger G, Diedrich P (2008) Biomechanics of the Keles Slider appliance for maxillary molar distalization—in-vitro analysis of force systems. J Orofac Orthop 69:365–372PubMedCrossRef Kinzinger G, Diedrich P (2008) Biomechanics of the Keles Slider appliance for maxillary molar distalization—in-vitro analysis of force systems. J Orofac Orthop 69:365–372PubMedCrossRef
30.
Zurück zum Zitat Kinzinger GS, Diedrich PR (2008) Biomechanics of a Distal Jet appliance. Theoretical considerations and in vitro analysis of force systems. Angle Orthod 78:676–681PubMedCrossRef Kinzinger GS, Diedrich PR (2008) Biomechanics of a Distal Jet appliance. Theoretical considerations and in vitro analysis of force systems. Angle Orthod 78:676–681PubMedCrossRef
31.
Zurück zum Zitat Kinzinger GS, Diedrich PR (2007) Biomechanics of a modified Pendulum appliance—theoretical considerations and in vitro analysis of the force systems. Eur J Orthod 29:1–7PubMedCrossRef Kinzinger GS, Diedrich PR (2007) Biomechanics of a modified Pendulum appliance—theoretical considerations and in vitro analysis of the force systems. Eur J Orthod 29:1–7PubMedCrossRef
32.
Zurück zum Zitat Kinzinger GS, Fritz UB, Sander FG et al (2004) Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage. Am J Orthod Dentofacial Orthop 125:8–23PubMedCrossRef Kinzinger GS, Fritz UB, Sander FG et al (2004) Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage. Am J Orthod Dentofacial Orthop 125:8–23PubMedCrossRef
33.
Zurück zum Zitat Kinzinger GS, Gulden N, Yildizhan F et al (2009) Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthop 136:578–586PubMedCrossRef Kinzinger GS, Gulden N, Yildizhan F et al (2009) Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthop 136:578–586PubMedCrossRef
34.
Zurück zum Zitat Kinzinger GS, Wehrbein H, Diedrich PR (2005) Molar distalization with a modified pendulum appliance—in vitro analysis of the force systems and in vivo study in children and adolescents. Angle Orthod 75:558–567PubMed Kinzinger GS, Wehrbein H, Diedrich PR (2005) Molar distalization with a modified pendulum appliance—in vitro analysis of the force systems and in vivo study in children and adolescents. Angle Orthod 75:558–567PubMed
35.
Zurück zum Zitat Kinzinger GS, Wehrbein H, Gross U et al (2006) Molar distalization with pendulum appliances in the mixed dentition: effects on the position of unerupted canines and premolars. Am J Orthod Dentofacial Orthop 129:407–417PubMedCrossRef Kinzinger GS, Wehrbein H, Gross U et al (2006) Molar distalization with pendulum appliances in the mixed dentition: effects on the position of unerupted canines and premolars. Am J Orthod Dentofacial Orthop 129:407–417PubMedCrossRef
36.
Zurück zum Zitat Kircelli BH, Pektas ZO, Kircelli C (2006) Maxillary molar distalization with a bone-anchored pendulum appliance. Angle Orthod 76:650–659PubMed Kircelli BH, Pektas ZO, Kircelli C (2006) Maxillary molar distalization with a bone-anchored pendulum appliance. Angle Orthod 76:650–659PubMed
37.
Zurück zum Zitat Kloehn S (1953) Orthodontics—force or persuasion. Angle Orthod 13:56–60 Kloehn S (1953) Orthodontics—force or persuasion. Angle Orthod 13:56–60
38.
Zurück zum Zitat Kyung SH, Hong SG, Park YC (2003) Distalization of maxillary molars with a midpalatal miniscrew. J Clin Orthod 37:22–26PubMed Kyung SH, Hong SG, Park YC (2003) Distalization of maxillary molars with a midpalatal miniscrew. J Clin Orthod 37:22–26PubMed
39.
Zurück zum Zitat Lee JS, Kim DH, Park YC et al (2004) The efficient use of midpalatal miniscrew implants. Angle Orthod 74:711–714PubMed Lee JS, Kim DH, Park YC et al (2004) The efficient use of midpalatal miniscrew implants. Angle Orthod 74:711–714PubMed
40.
Zurück zum Zitat Longerich UJ, Thurau M, Kolk A (2012) Development of a new device for maxillary molar distalization with high pseudoelastic forces to overcome slider friction: the Longslider-a modification of the Beneslider. Oral Surg Oral Med Oral Pathol Oral Radiol 20:e1–e13 Longerich UJ, Thurau M, Kolk A (2012) Development of a new device for maxillary molar distalization with high pseudoelastic forces to overcome slider friction: the Longslider-a modification of the Beneslider. Oral Surg Oral Med Oral Pathol Oral Radiol 20:e1–e13
41.
Zurück zum Zitat Ludwig B, Glasl B, Bowman SJ et al (2011) Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod 45:433–441 (quiz 467)PubMed Ludwig B, Glasl B, Bowman SJ et al (2011) Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod 45:433–441 (quiz 467)PubMed
42.
Zurück zum Zitat Maino BG, Weiland F, Attanasi A et al (2007) Root damage and repair after contact with miniscrews. J Clin Orthod 41:762–766 (quiz 750)PubMed Maino BG, Weiland F, Attanasi A et al (2007) Root damage and repair after contact with miniscrews. J Clin Orthod 41:762–766 (quiz 750)PubMed
43.
Zurück zum Zitat McSherry PF, Bradley H (2000) Class II correction-reducing patient compliance: a review of the available techniques. J Orthod 27:219–225PubMed McSherry PF, Bradley H (2000) Class II correction-reducing patient compliance: a review of the available techniques. J Orthod 27:219–225PubMed
44.
Zurück zum Zitat Melsen B, Costa A (2000) Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3:23–28PubMedCrossRef Melsen B, Costa A (2000) Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3:23–28PubMedCrossRef
45.
Zurück zum Zitat Miyawaki S, Koyama I, Inoue M et al (2003) Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 124:373–378PubMedCrossRef Miyawaki S, Koyama I, Inoue M et al (2003) Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 124:373–378PubMedCrossRef
46.
Zurück zum Zitat Ngantung V, Nanda RS, Bowman SJ (2001) Posttreatment evaluation of the distal jet appliance. Am J Orthod Dentofacial Orthop 120:178–185PubMedCrossRef Ngantung V, Nanda RS, Bowman SJ (2001) Posttreatment evaluation of the distal jet appliance. Am J Orthod Dentofacial Orthop 120:178–185PubMedCrossRef
47.
Zurück zum Zitat Oncag G, Seckin O, Dincer B et al (2007) Osseointegrated implants with pendulum springs for maxillary molar distalization: a cephalometric study. Am J Orthod Dentofacial Orthop 131:16–26PubMedCrossRef Oncag G, Seckin O, Dincer B et al (2007) Osseointegrated implants with pendulum springs for maxillary molar distalization: a cephalometric study. Am J Orthod Dentofacial Orthop 131:16–26PubMedCrossRef
48.
Zurück zum Zitat Polat-Ozsoy O, Kircelli BH, Arman-Ozcirpici A et al (2008) Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage. Am J Orthod Dentofacial Orthop 133:339 e339-339 e317PubMed Polat-Ozsoy O, Kircelli BH, Arman-Ozcirpici A et al (2008) Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage. Am J Orthod Dentofacial Orthop 133:339 e339-339 e317PubMed
49.
Zurück zum Zitat Schatzle M, Mannchen R, Zwahlen M et al (2009) Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res 20:1351–1359PubMedCrossRef Schatzle M, Mannchen R, Zwahlen M et al (2009) Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res 20:1351–1359PubMedCrossRef
50.
Zurück zum Zitat Sugawara J, Kanzaki R, Takahashi I et al (2006) Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system. Am J Orthod Dentofacial Orthop 129:723–733PubMedCrossRef Sugawara J, Kanzaki R, Takahashi I et al (2006) Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system. Am J Orthod Dentofacial Orthop 129:723–733PubMedCrossRef
51.
Zurück zum Zitat Triaca A, Antonini M, Wintermantel (1992) Ein neues Titanflachschrauben-Implantat zur orthodontischen Verankerung am anterioren Gaumen. Inf Orthod Kieferorthop 24:251–257 Triaca A, Antonini M, Wintermantel (1992) Ein neues Titanflachschrauben-Implantat zur orthodontischen Verankerung am anterioren Gaumen. Inf Orthod Kieferorthop 24:251–257
52.
Zurück zum Zitat Wehrbein H, Merz BR, Diedrich P et al (1996) The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res 7:410–416PubMedCrossRef Wehrbein H, Merz BR, Diedrich P et al (1996) The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res 7:410–416PubMedCrossRef
53.
Zurück zum Zitat Wiechmann D, Meyer U, Buchter A (2007) Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 18:263–267PubMedCrossRef Wiechmann D, Meyer U, Buchter A (2007) Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 18:263–267PubMedCrossRef
54.
Zurück zum Zitat Wilmes B, Drescher D (2010) Application and effectiveness of the Beneslider: a device to move molars distally. World J Orthod 11:331–340PubMed Wilmes B, Drescher D (2010) Application and effectiveness of the Beneslider: a device to move molars distally. World J Orthod 11:331–340PubMed
55.
Zurück zum Zitat Wilmes B, Drescher D (2011) Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Surg 40:697–703PubMedCrossRef Wilmes B, Drescher D (2011) Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Surg 40:697–703PubMedCrossRef
56.
Zurück zum Zitat Wilmes B, Drescher D (2009) Impact of insertion depth and predrilling diameter on primary stability of orthodontic mini-implants. Angle Orthod 79:609–614PubMedCrossRef Wilmes B, Drescher D (2009) Impact of insertion depth and predrilling diameter on primary stability of orthodontic mini-implants. Angle Orthod 79:609–614PubMedCrossRef
57.
Zurück zum Zitat Wilmes B, Drescher D (2008) A miniscrew system with interchangeable abutments. J Clin Orthod 42:574–580PubMed Wilmes B, Drescher D (2008) A miniscrew system with interchangeable abutments. J Clin Orthod 42:574–580PubMed
58.
Zurück zum Zitat Wilmes B, Drescher D, Nienkemper M (2009) A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 43:494–501PubMed Wilmes B, Drescher D, Nienkemper M (2009) A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 43:494–501PubMed
59.
Zurück zum Zitat Wilmes B, Nienkemper M, Ludwig B et al (2012) Esthetic Class II treatment with the Beneslider and aligners. J Clin Orthod 46:390–398PubMed Wilmes B, Nienkemper M, Ludwig B et al (2012) Esthetic Class II treatment with the Beneslider and aligners. J Clin Orthod 46:390–398PubMed
Metadaten
Titel
Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption
verfasst von
Dr. M. Nienkemper
B. Wilmes
A. Pauls
S. Yamaguchi
B. Ludwig
D. Drescher
Publikationsdatum
01.03.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Ausgabe 2/2014
Print ISSN: 1434-5293
Elektronische ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-013-0199-z

Weitere Artikel der Ausgabe 2/2014

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 2/2014 Zur Ausgabe

Informationen

Mitteilungsseiten

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.