Skip to main content
Erschienen in: Forensic Toxicology 1/2023

06.07.2022 | Original Article

Analysis of degradation products of nerve agents in biological fluids by ion chromatography–tandem mass spectrometry

verfasst von: Mai Otsuka, Hajime Miyaguchi

Erschienen in: Forensic Toxicology | Ausgabe 1/2023

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The detection of hydrolysis products of nerve agents (alkyl methylphosphonic acids; RMPAs) in biological samples from victims is important to confirm exposure to nerve agents. However, analysis of RMPAs is difficult due to their high hydrophilicity. The aim of this study was to develop ion chromatography–tandem mass spectrometry (IC–MS/MS) methods using commercially available equipment and columns to analyze RMPAs in human urine and serum with high sensitivity and without using complicate techniques.

Methods

A Dionex IonPac AS11-HC anion-exchange column was used to analyze six RMPAs (MPA, EMPA, IMPA, iBuMPA, CHMPA, and PMPA). For pretreatments of biological fluids, we developed two pretreatment methods (Method 1: dilution and ultrafiltration; Method 2: removal of chloride ions with Ag cartridges).

Results

Six RMPAs including highly hydrophilic methylphosphonic acid and ethyl methylphosphonic acid could be analyzed with sufficient retention times and peak shape. The detection limits of RMPAs were improved using Dionex OnGuard II Ba/Ag/H cartridges and MetaSEP IC–Ag cartridges (urine: 0.5–5 ng/mL; serum: 1–5 ng/mL). These methods were also applied to the test samples for the Organisation for the Prohibition of Chemical Weapons Biomedical Proficiency Tests.

Conclusions

RMPAs could be sufficiently analyzed by IC–MS/MS. In addition, the limits of detection were superior to those obtained in our previous study involving LC–MS/MS or derivatization–LC–MS/MS method. For analysis of biological samples, an appropriate pretreatment method can be chosen according to the amount of sample available for analysis and expected RMPA concentrations.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Kassa J (2002) Review of oximes in the antidotal treatment of poisoning by organophosphorus nerve agents. J Toxicol Cli Toxicol 40:803–816CrossRef Kassa J (2002) Review of oximes in the antidotal treatment of poisoning by organophosphorus nerve agents. J Toxicol Cli Toxicol 40:803–816CrossRef
3.
Zurück zum Zitat Seto Y, Tsunoda N, Kataoka M, Tsuge K, Nagano T (1999). In: Tu AA, Gaffield A (eds) Natural and selected synthetic toxins: biological implications. American Chemical Society, Washington, DC, pp 318–332CrossRef Seto Y, Tsunoda N, Kataoka M, Tsuge K, Nagano T (1999). In: Tu AA, Gaffield A (eds) Natural and selected synthetic toxins: biological implications. American Chemical Society, Washington, DC, pp 318–332CrossRef
4.
Zurück zum Zitat Noort D, Hulst AG, Platenburg DHJM, Polhuijs M, Benschop HP (1998) Quantitative analysis of O-isopropyl methylphosphonic acid in serum samples of Japanese citizens allegedly exposed to sarin: estimation of internal dosage. Arch Toxicol 72:671–675CrossRef Noort D, Hulst AG, Platenburg DHJM, Polhuijs M, Benschop HP (1998) Quantitative analysis of O-isopropyl methylphosphonic acid in serum samples of Japanese citizens allegedly exposed to sarin: estimation of internal dosage. Arch Toxicol 72:671–675CrossRef
5.
Zurück zum Zitat Tsuchihashi H, Katagi M, Nishikawa M, Tatsuno M (1998) Identification of metabolites of nerve agent VX in serum collected from a victim. J Anal Toxicol 22:383–388CrossRef Tsuchihashi H, Katagi M, Nishikawa M, Tatsuno M (1998) Identification of metabolites of nerve agent VX in serum collected from a victim. J Anal Toxicol 22:383–388CrossRef
6.
Zurück zum Zitat Yang YC, Baker JA, Ward JR (1992) Decontamination of chemical warfare agents. Chem Rev 92:1729–1743CrossRef Yang YC, Baker JA, Ward JR (1992) Decontamination of chemical warfare agents. Chem Rev 92:1729–1743CrossRef
7.
Zurück zum Zitat Seto Y (2011) Research and development of on-site decontamination system for biological and chemical warfare agents. J Health Sci 57:311–333CrossRef Seto Y (2011) Research and development of on-site decontamination system for biological and chemical warfare agents. J Health Sci 57:311–333CrossRef
8.
Zurück zum Zitat Seto Y (2015). In: Gupta RC (ed) Handbook of the toxicology of chemical warfare agents, 2nd edn. Elsevier, Amsterdam, pp 897–914CrossRef Seto Y (2015). In: Gupta RC (ed) Handbook of the toxicology of chemical warfare agents, 2nd edn. Elsevier, Amsterdam, pp 897–914CrossRef
9.
Zurück zum Zitat Black RM, Read RW (2013) Biological markers of exposure to organophosphorus nerve agents. Arch Toxicol 87:421–437CrossRef Black RM, Read RW (2013) Biological markers of exposure to organophosphorus nerve agents. Arch Toxicol 87:421–437CrossRef
10.
Zurück zum Zitat Munro NB, Talmage SS, Griffin GD, Waters LC, Watson AP, King JF, Hauschild V (1999) The sources, fate, and toxicity of chemical warfare agent degradation products. Environ Health Perspect 107:933–974CrossRef Munro NB, Talmage SS, Griffin GD, Waters LC, Watson AP, King JF, Hauschild V (1999) The sources, fate, and toxicity of chemical warfare agent degradation products. Environ Health Perspect 107:933–974CrossRef
11.
Zurück zum Zitat Black RM, Read RW, Muir B (2003) Derivatisation reactions in the chromatographic analysis of chemical warfare agents and their degradation products. J Chromatogr A 1000:253–281CrossRef Black RM, Read RW, Muir B (2003) Derivatisation reactions in the chromatographic analysis of chemical warfare agents and their degradation products. J Chromatogr A 1000:253–281CrossRef
12.
Zurück zum Zitat Jang YJ, Kim K, Tsay OG, Atwood DA, Churchill DG (2015) Destruction and detection of chemical warfare agents. Chem Rev 115:PR1–PR76CrossRef Jang YJ, Kim K, Tsay OG, Atwood DA, Churchill DG (2015) Destruction and detection of chemical warfare agents. Chem Rev 115:PR1–PR76CrossRef
13.
Zurück zum Zitat Black RM, Read RW (1997) Application of liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry, and tandem mass spectrometry, to the analysis and identification of degradation products of chemical warfare agents. J Chromatogr A 759:79–92CrossRef Black RM, Read RW (1997) Application of liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry, and tandem mass spectrometry, to the analysis and identification of degradation products of chemical warfare agents. J Chromatogr A 759:79–92CrossRef
14.
Zurück zum Zitat Hamelin EI, Schulze ND, Shaner RL, Coleman RM, Lawrence RJ, Crow BS, Jakubowski EM, Johnson RC (2014) Quantitation of five organophosphorus nerve agent metabolites in serum using hydrophilic interaction liquid chromatography and tandem mass spectrometry. Anal Bioanal Chem 406:5195–5202CrossRef Hamelin EI, Schulze ND, Shaner RL, Coleman RM, Lawrence RJ, Crow BS, Jakubowski EM, Johnson RC (2014) Quantitation of five organophosphorus nerve agent metabolites in serum using hydrophilic interaction liquid chromatography and tandem mass spectrometry. Anal Bioanal Chem 406:5195–5202CrossRef
15.
Zurück zum Zitat Røen BT, Sellevåg SR, Dybendal KE, Lundanes E (2014) Trace determination of primary nerve agent degradation products in aqueous soil extracts by on-line solid phase extraction-liquid chromatography-mass spectrometry using ZrO2 for enrichment. J Chromatogr A 1329:90–97CrossRef Røen BT, Sellevåg SR, Dybendal KE, Lundanes E (2014) Trace determination of primary nerve agent degradation products in aqueous soil extracts by on-line solid phase extraction-liquid chromatography-mass spectrometry using ZrO2 for enrichment. J Chromatogr A 1329:90–97CrossRef
16.
Zurück zum Zitat Lee JY, Lee YH (2014) Rapid screening and determination of nerve agent metabolites in human urine by LC–MS/MS. J Anal Chem 69:909–916CrossRef Lee JY, Lee YH (2014) Rapid screening and determination of nerve agent metabolites in human urine by LC–MS/MS. J Anal Chem 69:909–916CrossRef
17.
Zurück zum Zitat Otsuka M, Tsuge K, Miyaguchi H, Uchiyama M (2018) Analysis of degradation products of nerve agents via post-pentafluorobenzylation liquid chromatography–tandem mass spectrometry. J Chromatogr A 1577:31–37CrossRef Otsuka M, Tsuge K, Miyaguchi H, Uchiyama M (2018) Analysis of degradation products of nerve agents via post-pentafluorobenzylation liquid chromatography–tandem mass spectrometry. J Chromatogr A 1577:31–37CrossRef
18.
Zurück zum Zitat Røen BT, Sellevag SR, Lundanes E (2014) Quantification of nerve agent biomarkers in human serum and urine. Anal Chem 86:11833–11840CrossRef Røen BT, Sellevag SR, Lundanes E (2014) Quantification of nerve agent biomarkers in human serum and urine. Anal Chem 86:11833–11840CrossRef
19.
Zurück zum Zitat Mawhinney DB, Hamelin EH, Fraser R, Silva SS, Pavlopoulos AJ, Kobelski RJ (2007) The determination of organophosphonate nerve agent metabolites in human urine by hydrophilic interaction liquid chromatography tandem mass spectrometry. J Chromatogr B 852:235–243CrossRef Mawhinney DB, Hamelin EH, Fraser R, Silva SS, Pavlopoulos AJ, Kobelski RJ (2007) The determination of organophosphonate nerve agent metabolites in human urine by hydrophilic interaction liquid chromatography tandem mass spectrometry. J Chromatogr B 852:235–243CrossRef
20.
Zurück zum Zitat Kingery AF, Allen HE (1994) Ion chromatographic separation of closely related nerve agent degradation products using an organic modifier to provide selectivity. Anal Chem 66:155–159CrossRef Kingery AF, Allen HE (1994) Ion chromatographic separation of closely related nerve agent degradation products using an organic modifier to provide selectivity. Anal Chem 66:155–159CrossRef
21.
Zurück zum Zitat Piao H, Marx RB, Schneider S, Irvine DA, Staton J (2005) Analysis of VX nerve agent hydrolysis products in wastewater effluents by ion chromatography with amperometric and conductivity detection. J Chromatogr A 1089:65–71CrossRef Piao H, Marx RB, Schneider S, Irvine DA, Staton J (2005) Analysis of VX nerve agent hydrolysis products in wastewater effluents by ion chromatography with amperometric and conductivity detection. J Chromatogr A 1089:65–71CrossRef
22.
Zurück zum Zitat Katagi M, Nishikawa M, Tatsuno M, Tsuchihashi H (1997) Determination of the main hydrolysis products of organophosphorus nerve agents, methylphosphonic acids, in human serum by indirect photometric detection ion chromatography. J Chromatogr B 698:81–88CrossRef Katagi M, Nishikawa M, Tatsuno M, Tsuchihashi H (1997) Determination of the main hydrolysis products of organophosphorus nerve agents, methylphosphonic acids, in human serum by indirect photometric detection ion chromatography. J Chromatogr B 698:81–88CrossRef
23.
Zurück zum Zitat Tokarz JAIII, Ginter JM, Shefcheck KJ (2017) Ion chromatography (IC). In: Vanninen P (ed) Recommended operating procedures for analysis in the verification of chemical disarmament. University of Helsinki, Finland, pp 405–415 Tokarz JAIII, Ginter JM, Shefcheck KJ (2017) Ion chromatography (IC). In: Vanninen P (ed) Recommended operating procedures for analysis in the verification of chemical disarmament. University of Helsinki, Finland, pp 405–415
24.
Zurück zum Zitat Baygildiev T, Vokuev M, Ogorodnikov R, Braun A, Rybalchenko I, Rodin I (2019) Simultaneous determination of organophosphorus nerve agent markers in urine by IC-MS/MS using anion-exchange solid-phase extraction. J Chromatogr B 1132:121815CrossRef Baygildiev T, Vokuev M, Ogorodnikov R, Braun A, Rybalchenko I, Rodin I (2019) Simultaneous determination of organophosphorus nerve agent markers in urine by IC-MS/MS using anion-exchange solid-phase extraction. J Chromatogr B 1132:121815CrossRef
25.
Zurück zum Zitat Seto Y, Tachikawa M, Kanamori-Kataoka M, Sasamoto K, Ochiai N (2017) Target analysis of tert-butyldimethylsilyl derivatives of nerve agent hydrolysis products by selectable one-dimensional or two-dimensional gas chromatography-mass spectrometry. J Chromatogr A 1501:99–106CrossRef Seto Y, Tachikawa M, Kanamori-Kataoka M, Sasamoto K, Ochiai N (2017) Target analysis of tert-butyldimethylsilyl derivatives of nerve agent hydrolysis products by selectable one-dimensional or two-dimensional gas chromatography-mass spectrometry. J Chromatogr A 1501:99–106CrossRef
26.
Zurück zum Zitat Dubey V, Velikeloth S, Sliwakowski M, Mallard G (2009) Official proficiency tests of the organisation for the prohibition of chemical weapons: current status and future directions. Accred Qual Assur 14:431–437CrossRef Dubey V, Velikeloth S, Sliwakowski M, Mallard G (2009) Official proficiency tests of the organisation for the prohibition of chemical weapons: current status and future directions. Accred Qual Assur 14:431–437CrossRef
27.
Zurück zum Zitat Quality System Document of the OPCW: Work Instruction for the Reporting of the Results of the OPCW Biomedical Proficiency Tests (QDOC_LAB_WI_BioPT04 (Issue 1, Revision 1, dated 28 December 2016)) Quality System Document of the OPCW: Work Instruction for the Reporting of the Results of the OPCW Biomedical Proficiency Tests (QDOC_LAB_WI_BioPT04 (Issue 1, Revision 1, dated 28 December 2016))
30.
Zurück zum Zitat Baygildiev TM, Vokuev MF, Braun AV, Yashkir VA, Rybalchenko IV, Rodin IA (2021) Identification of 2-(diethylamino)ethylthiol dipeptide (Cys-Pro) adduct as biomarker of nerve agents VR and CVX in human plasma using liquid chromatography-high-resolution tandem mass spectrometry. Anal Bioanal Chem 413:1905–1916CrossRef Baygildiev TM, Vokuev MF, Braun AV, Yashkir VA, Rybalchenko IV, Rodin IA (2021) Identification of 2-(diethylamino)ethylthiol dipeptide (Cys-Pro) adduct as biomarker of nerve agents VR and CVX in human plasma using liquid chromatography-high-resolution tandem mass spectrometry. Anal Bioanal Chem 413:1905–1916CrossRef
31.
Zurück zum Zitat Nakajima T, Sasaki K, Ozawa H, Sekijima Y, Morita H, Fukushima Y, Yanagisawa N (1998) Urinary metabolites of sarin in a patient of the Matsumoto sarin incident. Arch Toxicol 72:601–603CrossRef Nakajima T, Sasaki K, Ozawa H, Sekijima Y, Morita H, Fukushima Y, Yanagisawa N (1998) Urinary metabolites of sarin in a patient of the Matsumoto sarin incident. Arch Toxicol 72:601–603CrossRef
32.
Zurück zum Zitat Carlson M, Thompson RD (2000) Analyte loss due to membrane filter adsorption as determined by high-performance liquid chromatography. J Chromatogr Sci 38:77–83CrossRef Carlson M, Thompson RD (2000) Analyte loss due to membrane filter adsorption as determined by high-performance liquid chromatography. J Chromatogr Sci 38:77–83CrossRef
Metadaten
Titel
Analysis of degradation products of nerve agents in biological fluids by ion chromatography–tandem mass spectrometry
verfasst von
Mai Otsuka
Hajime Miyaguchi
Publikationsdatum
06.07.2022
Verlag
Springer Nature Singapore
Erschienen in
Forensic Toxicology / Ausgabe 1/2023
Print ISSN: 1860-8965
Elektronische ISSN: 1860-8973
DOI
https://doi.org/10.1007/s11419-022-00633-x

Weitere Artikel der Ausgabe 1/2023

Forensic Toxicology 1/2023 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin

Assistierter Suizid durch Infusion von Thiopental

Thiopental Originalie

Als Folge des Urteils des Bundesverfassungsgerichts zur Sterbehilfe im Jahr 2020 wurde in den Jahren 2021–2023 eine Reihe (n = 23) von assistierten Suiziden im Landesinstitut für gerichtliche und soziale Medizin Berlin mit jeweils identischen …

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …