verfasst von: Bradley C. Clark, Melissa Olen, Brynn Dechert, Caitlin Brateng, Beth Jarosz, Karen Smoots, Patrick Connell, Svjetlana Tisma Dupanovic, Arnold Fenrich, Allison C. Hill, Martin LaPage, Douglas Mah, Anthony McCanta, Lindsey Malloy-Walton, Andreas Pflaumer, Andrew Radbill, Ronn Tanel, Robert Whitehill, Aarti Dalal, the Pediatric and Congenital Electrophysiology Society (PACES)

Erschienen in: Pediatric Cardiology | Ausgabe 1/2024

Einloggen, um Zugang zu erhalten

Abstract

Cardiac implantable electronic device (CIED) remote transmissions are an integral part of longitudinal follow-up in pediatric and adult congenital heart disease (ACHD) patients. To evaluate baseline CIED remote monitoring (RM) data among pediatric and ACHD centers prior to implementation of a Pediatric and Congenital Electrophysiology  Society (PACES)-sponsored quality improvement (QI) project. This is a cross-sectional study of baseline CIED RM. Centers self-reported baseline data: individual center RM compliance was defined as high if there was > 80% achievement and low if < 50%. A total of 22 pediatric centers in the USA and Australia submitted baseline data. Non-physicians were responsible for management of the RM program in most centers: registered nurse (36%), advanced practice provider (27%), combination (23%), and third party (9%). Fifteen centers (68%) reported that > 80% of their CIED patients are enrolled in RM and only two centers reported < 50% participation. 36% reported high compliance of device transmission within 14 days of implant and 77% of centers reported high compliance of CIED patients enrolled in RM. The number of centers achieving high compliance differed by device type: 36% for pacemakers, 50% for ICDs, and 55% for Implantable Cardiac Monitors (ICM). All centers reported at least 50% adherence to recommended follow-up for PM and ICD, with 23% low compliance rate for ICMs. Based on this cross-sectional survey of pediatric and ACHD centers, compliance with CIED RM is sub-optimal. The PACES-sponsored QI initiative will provide resources and support to participating centers and repeat data will be evaluated after PDSA cycles.
Literatur
6.
Zurück zum Zitat Shah MJ, Silka MJ, Silva JNA, Balaji S, Beach CM, Benjamin MN, Berul CI, Cannon B, Cecchin F, Cohen MI et al (2021) 2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients: developed in collaboration with and endorsed by the Heart Rhythm Society (HRS), the American College of Cardiology (ACC), the American Heart Association (AHA), and the Association for European Paediatric and Congenital Cardiology (AEPC) Endorsed by the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). JACC Clin Electrophysiol 7:1437–1472. https://doi.org/10.1016/j.jacep.2021.07.009CrossRefPubMed Shah MJ, Silka MJ, Silva JNA, Balaji S, Beach CM, Benjamin MN, Berul CI, Cannon B, Cecchin F, Cohen MI et al (2021) 2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients: developed in collaboration with and endorsed by the Heart Rhythm Society (HRS), the American College of Cardiology (ACC), the American Heart Association (AHA), and the Association for European Paediatric and Congenital Cardiology (AEPC) Endorsed by the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). JACC Clin Electrophysiol 7:1437–1472. https://​doi.​org/​10.​1016/​j.​jacep.​2021.​07.​009CrossRefPubMed
Metadaten
Titel
Current State of Cardiac Implantable Electronic Device Remote Monitoring in Pediatrics and Congenital Heart Disease: A PACES-Sponsored Quality Improvement Initiative
verfasst von
Bradley C. Clark
Melissa Olen
Brynn Dechert
Caitlin Brateng
Beth Jarosz
Karen Smoots
Patrick Connell
Svjetlana Tisma Dupanovic
Arnold Fenrich
Allison C. Hill
Martin LaPage
Douglas Mah
Anthony McCanta
Lindsey Malloy-Walton
Andreas Pflaumer
Andrew Radbill
Ronn Tanel
Robert Whitehill
Aarti Dalal
the Pediatric and Congenital Electrophysiology Society (PACES)
Publikationsdatum
30.11.2023
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 1/2024
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-023-03348-x

Weitere Artikel der Ausgabe 1/2024

Pediatric Cardiology 1/2024 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.