Abstract

Purpose

To evaluate the effects of anodization on the friction behavior of beta-titanium (β-Ti) orthodontic archwires in conventional or self-ligating brackets in vitro.

Methods

β‑Ti archwires (0.018 × 0.025 inch) pre- and postanodization were tested in combination with 0.022-inch stainless steel conventional and self-ligating brackets. The surface composition and oxide thickness of the β‑Ti archwires pre- and postanodization were measured using Auger electron spectroscopy (AES) and transmission electron microscopy (TEM). Detailed surface topography and roughness were assessed using atomic force microscopy (AFM). Surface topographies of the β‑Ti archwires pre- and postanodization were examined using scanning electron microscopy (SEM). Friction was measured using a universal testing machine; the data were statistically analyzed.

Results

Postanodization, the identified titanium oxide layer on the surface of the β‑Ti archwires increased in thickness from 10 to 100 nm; at the same time, the values for surface roughness were significantly reduced by half (p < 0.001). The archwire surfaces post anodization were harder and had fewer scratches after the friction test. Anodization significantly reduced 23.77% of the static (p < 0.01) and 25.61% of the kinetic (p < 0.001) friction of the β‑Ti archwires in conventional brackets, while it significantly reduced 85.71% of the static and 84.38% of the kinetic friction (p < 0.01) in self-ligating brackets.

Conclusion

Anodization reduced the β‑Ti archwire friction, which was particularly more effective in combination with self-ligating brackets. The friction reduction via anodization could be attributed to the increased thickness, surface hardness, and decreased surface roughness of the titanium oxide layer.
Literatur
10.
Zurück zum Zitat Aladjem A (1973) Anodic oxidation of titanium and its alloys. J Mater Sci 8:688–704CrossRef Aladjem A (1973) Anodic oxidation of titanium and its alloys. J Mater Sci 8:688–704CrossRef
14.
Zurück zum Zitat Soares P, Mikowski A, Lepienski CM, Santos E Jr, Soares GA, Filho VS, Kuromoto NK (2008) Hardness and elastic modulus of TiO2 anodic films measured by instrumented indentation. J Biomed Mater Res Part B Appl Biomater 84B:524–530. https://doi.org/10.1002/jbm.b.30900CrossRef Soares P, Mikowski A, Lepienski CM, Santos E Jr, Soares GA, Filho VS, Kuromoto NK (2008) Hardness and elastic modulus of TiO2 anodic films measured by instrumented indentation. J Biomed Mater Res Part B Appl Biomater 84B:524–530. https://​doi.​org/​10.​1002/​jbm.​b.​30900CrossRef
17.
Zurück zum Zitat Trigwell S, Hayden RD, Nelson KF, Selvaduray G (1998) Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications. Surf Interface Anal 26:483–489. https://doi.org/10.1002/(SICI)1096-9918(199806)26:7〈483::AID-SIA388〉3.0.CO;2‑5CrossRef Trigwell S, Hayden RD, Nelson KF, Selvaduray G (1998) Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications. Surf Interface Anal 26:483–489. https://​doi.​org/​10.​1002/​(SICI)1096-9918(199806)26:7〈483::AID-SIA388〉3.0.CO;2‑5CrossRef
20.
Zurück zum Zitat Kasemo B, Lausmaa J (1985) Aspect of surface physics on titanium implants. Swed Dent J Suppl 28:19–36PubMed Kasemo B, Lausmaa J (1985) Aspect of surface physics on titanium implants. Swed Dent J Suppl 28:19–36PubMed
22.
Zurück zum Zitat Glaeser WA (1970) An engineer’s guide to friction. Defense Metal Information Center, Battelle Memorial Institute, Columbus, Ohio Glaeser WA (1970) An engineer’s guide to friction. Defense Metal Information Center, Battelle Memorial Institute, Columbus, Ohio
25.
Zurück zum Zitat Burstone CJ, Frazin-Nia F (1995) Production of low-friction and colored TMA by ion implantation. J Clin Orthod 29:453–461.PubMed Burstone CJ, Frazin-Nia F (1995) Production of low-friction and colored TMA by ion implantation. J Clin Orthod 29:453–461.PubMed
37.
Zurück zum Zitat Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P (2014) A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022″ slot brackets in dry state: an in vitro study. J Int Oral Health 6:76–83PubMedPubMedCentral Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P (2014) A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022″ slot brackets in dry state: an in vitro study. J Int Oral Health 6:76–83PubMedPubMedCentral
39.
Zurück zum Zitat Sridharan K, Sandbhor S, Rajasekaran UB, Sam G, Ramees MM, Abraham EA (2017) An in vitro evaluation of friction characteristics of conventional stainless steel and self-ligating stainless steel brackets with different dimensions of archwires in various bracket-archwire combination. J Contemp Dent Pract 18:660–664. https://doi.org/10.5005/jp-journals-10024-2102CrossRefPubMed Sridharan K, Sandbhor S, Rajasekaran UB, Sam G, Ramees MM, Abraham EA (2017) An in vitro evaluation of friction characteristics of conventional stainless steel and self-ligating stainless steel brackets with different dimensions of archwires in various bracket-archwire combination. J Contemp Dent Pract 18:660–664. https://​doi.​org/​10.​5005/​jp-journals-10024-2102CrossRefPubMed
Metadaten
Titel
Effect of anodization on friction behavior of β‑titanium orthodontic archwires
verfasst von
Yueh-Tse Lee
Eric Jein-Wein Liou
Li-Ling Huang
Hsin-Jay Wu
Sinn-Wen Chen
Publikationsdatum
17.09.2021
Verlag
Springer Medizin
Erschienen in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Ausgabe 4/2023
Print ISSN: 1434-5293
Elektronische ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-021-00347-6

Weitere Artikel der Ausgabe 4/2023

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 4/2023 Zur Ausgabe

Mitteilungen der DGKFO

Mitteilungen der DGKFO

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.