Skip to main content
Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 5/2014

01.09.2014 | Original article

Effect of ionizing radiation on polymer brackets

verfasst von: A. Faltermeier, C. Reicheneder, P. Römer, A. Castro-Laza, P. Proff

Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Ausgabe 5/2014

Einloggen, um Zugang zu erhalten

Abstract

Objective

The purpose of this study was to investigate whether the mechanical properties of polymer brackets can be improved without discoloration by electron beam (EB) irradiation applied with a Rhodotron electron accelerator using standard high-energy parameters including a 10 MV acceleration voltage and 100 kGy of energy. We analyzed polymer samples and several commercially available brackets.

Materials and methods

The first group included three polymeric base materials (polyoxymethylene, polycarbonate, polyurethane) currently used in various bracket systems. The second group included five bracket types, three of which are on the market (Aesthetik-Line and Brillant by Forestadent; Envision by Ortho Organizers) while the other two were experimental brackets containing urethane dimethacrylate as a monomer matrix and functional silane-treated SiO2 fillers with a filler content of 10 or 40 vol%. Each category included 40 specimens previously irradiated by a commercial provider (Beta-Gamma-Service, Bruchsal, Germany) and another 40 nonirradiated controls. The polymer specimens were analyzed for fracture toughness, Vickers hardness, and wear resistance, and the bracket specimens for Vickers hardness and color stability. The Wilcoxon–Mann–Whitney U test was used for pairwise comparison to identify significant differences (p ≤ 0.05).

Results

Significant increases in fracture toughness and Vickers hardness were observed in polycarbonate and polyurethane after EB irradiation, while EB irradiation of polyoxymethylene resulted in a significant decrease in these parameters. The polyurethane samples demonstrated significantly less postirradiation wear. All the commercially available brackets except for Brillant revealed significant increases in Vickers hardness. Significant discoloration was observed in all brackets after irradiation.

Conclusion

Although our evaluation of polymer brackets revealed considerable improvements in mechanical properties after EB irradiation, this benefit was marred by very obvious discoloration. We cannot therefore recommend industrial scale EB irradiation for any polymer bracket currently on the market.
Literatur
1.
Zurück zum Zitat Arici S, Regan D (1997) Alternatives to ceramic brackets: the tensile bond strength of two aesthetic brackets compared ex vivo with stainless steel foil-mesh bracket bases. Br J Orthod 24:133–137PubMedCrossRef Arici S, Regan D (1997) Alternatives to ceramic brackets: the tensile bond strength of two aesthetic brackets compared ex vivo with stainless steel foil-mesh bracket bases. Br J Orthod 24:133–137PubMedCrossRef
2.
Zurück zum Zitat Barlow A, Biggs JW, Meeks LA (1981) Radiation processing of polyethylene. Radiat Phys Chem 18:267–280 Barlow A, Biggs JW, Meeks LA (1981) Radiation processing of polyethylene. Radiat Phys Chem 18:267–280
3.
Zurück zum Zitat Behr M, Rosentritt M, Faltermeier A et al (2005) Electron beam irradiation of denture base materials. J Mater Sci Mater Med 16:175–181PubMedCrossRef Behr M, Rosentritt M, Faltermeier A et al (2005) Electron beam irradiation of denture base materials. J Mater Sci Mater Med 16:175–181PubMedCrossRef
4.
Zurück zum Zitat Behr M, Rosentritt M, Faltermeier A et al (2005) Electron beam irradiation of dental composites. Dent Mater 21:804–810PubMedCrossRef Behr M, Rosentritt M, Faltermeier A et al (2005) Electron beam irradiation of dental composites. Dent Mater 21:804–810PubMedCrossRef
5.
Zurück zum Zitat Behr M, Rosentritt M, Bettermann K et al (2005) Influence of electron beam irradiation on the alloy-to-resin bond strength. Eur J Oral Sci 113:429–435PubMedCrossRef Behr M, Rosentritt M, Bettermann K et al (2005) Influence of electron beam irradiation on the alloy-to-resin bond strength. Eur J Oral Sci 113:429–435PubMedCrossRef
6.
Zurück zum Zitat Charlesby A, Pinner SH (1959) Analysis of the solubility behaviour of irradiated polyethylene and other polymers. Math Phys Sci 249:367–386CrossRef Charlesby A, Pinner SH (1959) Analysis of the solubility behaviour of irradiated polyethylene and other polymers. Math Phys Sci 249:367–386CrossRef
7.
Zurück zum Zitat Condon JR, Ferracane JL (1997) Factors effecting dental composite wear in vitro. Appl Biomater 38:303–331 Condon JR, Ferracane JL (1997) Factors effecting dental composite wear in vitro. Appl Biomater 38:303–331
8.
Zurück zum Zitat DeGee AJ, Pallav P (1994) Occlusal wear simulation with the ACTA wear machine. J Dent 22:21–27CrossRef DeGee AJ, Pallav P (1994) Occlusal wear simulation with the ACTA wear machine. J Dent 22:21–27CrossRef
9.
Zurück zum Zitat Faltermeier A (2005) Modifikation dentaler Polymere mittels hochenergetischer Elektronenbestrahlung. Dissertation, Medizinische Fakultät der Universität Regensburg Faltermeier A (2005) Modifikation dentaler Polymere mittels hochenergetischer Elektronenbestrahlung. Dissertation, Medizinische Fakultät der Universität Regensburg
10.
Zurück zum Zitat Faltermeier A, Behr M, Rosentritt M et al (2007) Electron-beam irradiation of experimental denture base polymers. Acta Odontol Scand 65(3):171–177PubMedCrossRef Faltermeier A, Behr M, Rosentritt M et al (2007) Electron-beam irradiation of experimental denture base polymers. Acta Odontol Scand 65(3):171–177PubMedCrossRef
11.
Zurück zum Zitat Faltermeier A, Rosentritt M, Reicheneder C et al (2011) Electron beam irradiation of polymer bracket materials. Am J Orthod Dentofacial Orthop 139(1):e7–e11PubMedCrossRef Faltermeier A, Rosentritt M, Reicheneder C et al (2011) Electron beam irradiation of polymer bracket materials. Am J Orthod Dentofacial Orthop 139(1):e7–e11PubMedCrossRef
12.
Zurück zum Zitat Faltermeier J, Simon P, Reicheneder C et al (2012) The influence of electron beam irradiation on colour stability and hardness of aesthetic brackets. Eur J Orthod 34(4):427–431PubMedCrossRef Faltermeier J, Simon P, Reicheneder C et al (2012) The influence of electron beam irradiation on colour stability and hardness of aesthetic brackets. Eur J Orthod 34(4):427–431PubMedCrossRef
13.
Zurück zum Zitat Ferracane JL, Mitchem JC, Condon JR et al (1997) Wear and marginal breakdown of composites with various degrees of cure. J Dent Res 76(8):1508–1516PubMedCrossRef Ferracane JL, Mitchem JC, Condon JR et al (1997) Wear and marginal breakdown of composites with various degrees of cure. J Dent Res 76(8):1508–1516PubMedCrossRef
14.
Zurück zum Zitat Göhring TN, Gallo L, Lüthy H (2005) Effect of water storage, thermocycling, the incorporation and site of placement of glass-fibers on the flexural strength of veneering composite. Dent Mater 21:761–772PubMedCrossRef Göhring TN, Gallo L, Lüthy H (2005) Effect of water storage, thermocycling, the incorporation and site of placement of glass-fibers on the flexural strength of veneering composite. Dent Mater 21:761–772PubMedCrossRef
15.
Zurück zum Zitat Haque S, Takinami S, Watari F et al (2001) Radiation effects of carbon ions and gamma ray UDMA based dental resin. Dent Mater J 20:325–338PubMedCrossRef Haque S, Takinami S, Watari F et al (2001) Radiation effects of carbon ions and gamma ray UDMA based dental resin. Dent Mater J 20:325–338PubMedCrossRef
16.
Zurück zum Zitat Peutzfeldt A, Asmussen E (2000) The effect of post-curing on quantity of remaining double bonds, mechanical properties, and in vitro wear of two resin composites. J Dent 28:447–452PubMedCrossRef Peutzfeldt A, Asmussen E (2000) The effect of post-curing on quantity of remaining double bonds, mechanical properties, and in vitro wear of two resin composites. J Dent 28:447–452PubMedCrossRef
17.
Zurück zum Zitat Seguchi T, Yagi T, Ishikawa S et al (2002) New material synthesis by radiation processing at high temperature- polymer modification with improved irradiation technology. Radiat Phys Chem 63:35–40CrossRef Seguchi T, Yagi T, Ishikawa S et al (2002) New material synthesis by radiation processing at high temperature- polymer modification with improved irradiation technology. Radiat Phys Chem 63:35–40CrossRef
18.
Zurück zum Zitat Tada S (1983) Application of irradiated wires. Radiat Phys Chem 22:575–582 Tada S (1983) Application of irradiated wires. Radiat Phys Chem 22:575–582
19.
Zurück zum Zitat Thompson D, Song JH, Wilkes GL (1987) Electron beam effects on polymers: structure-property behavior of radiation-cured Bis-GMA. J Appl Polymer Sci 34:1063–1080CrossRef Thompson D, Song JH, Wilkes GL (1987) Electron beam effects on polymers: structure-property behavior of radiation-cured Bis-GMA. J Appl Polymer Sci 34:1063–1080CrossRef
20.
Zurück zum Zitat Ungar G (1981) Radiation effects in polyethylene and n-alkanes. J Mater Sci 16:2635–2656CrossRef Ungar G (1981) Radiation effects in polyethylene and n-alkanes. J Mater Sci 16:2635–2656CrossRef
21.
Zurück zum Zitat Williams JG, Cawood MJ (1990) European group on fracture: Kc and Gc methods for polymers. Polymer Testing 9:15–26CrossRef Williams JG, Cawood MJ (1990) European group on fracture: Kc and Gc methods for polymers. Polymer Testing 9:15–26CrossRef
22.
Zurück zum Zitat Zinelis S, Eliades T, Eliades G et al (2005) Comparative assessment of the roughness, hardness, and wear resistance of aesthetic bracket materials. Dent Mater J 21:890–894CrossRef Zinelis S, Eliades T, Eliades G et al (2005) Comparative assessment of the roughness, hardness, and wear resistance of aesthetic bracket materials. Dent Mater J 21:890–894CrossRef
Metadaten
Titel
Effect of ionizing radiation on polymer brackets
verfasst von
A. Faltermeier
C. Reicheneder
P. Römer
A. Castro-Laza
P. Proff
Publikationsdatum
01.09.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Ausgabe 5/2014
Print ISSN: 1434-5293
Elektronische ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-014-0229-5

Weitere Artikel der Ausgabe 5/2014

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 5/2014 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.