Abstract

Reducing treatment time is one of the most important trends in modern dentistry. This study aimed to compare the micro-leakage around the resin sealants when using both high and conventional intensity light-curing systems. The study sample consisted of 30 extracted human maxillary premolar teeth that were divided into two equal groups according to the light-curing system used: Group 1, High-Intensity Light-Curing System and Group 2, Conventional Light-Curing System. Light-curing by Woodpecker I-LED device with two intensities (high and conventional) has been used. All teeth were subjected to 500 cycles of thermocycling. Then, a methylene blue dye microleakage test was performed, and the teeth were sectioned longitudinally and studied under a stereo microscope. The mean of micro-leakage in the high-intensity group (1.33 ± 1.29) was less than in the conventional intensity group (1.63 ± 1.29) without any statistically significant differences (p = 0.320). The high-intensity light-curing system mode may be a good and acceptable alternative to conventional intensity light-curing system mode in polymerization of pits and fissure sealants.
Literatur
8.
Zurück zum Zitat Malhotra N, Kundabala M (2010) Light-curing considerations for resin-based composite materials: a review. Part I CompendContinEduc Dent 31(7):498–505 Malhotra N, Kundabala M (2010) Light-curing considerations for resin-based composite materials: a review. Part I CompendContinEduc Dent 31(7):498–505
11.
Zurück zum Zitat Cooley RL, McCourt JW (1990) Evaluation of by SEM, microleakage, and fluoride release. Pediatr Dent 12(1):39 Cooley RL, McCourt JW (1990) Evaluation of by SEM, microleakage, and fluoride release. Pediatr Dent 12(1):39
12.
Zurück zum Zitat Condò R et al (2013) Sealants in dentistry: a systematic review of the literature. Oral and Implantology 6(3):67PubMed Condò R et al (2013) Sealants in dentistry: a systematic review of the literature. Oral and Implantology 6(3):67PubMed
13.
Zurück zum Zitat Sanders BJ, Feigal RJ, Avery DR (2010) Pit and fissure sealants and preventive resin restorations. Dentistry for the child and adolescent, 9th edn. Mosby, St. Louis, pp 313–321 Sanders BJ, Feigal RJ, Avery DR (2010) Pit and fissure sealants and preventive resin restorations. Dentistry for the child and adolescent, 9th edn. Mosby, St. Louis, pp 313–321
16.
Zurück zum Zitat Townsend JA, Wells MH (2019) Behavior guidance of the pediatric dental patient, in Pediatric dentistry. Elsevier, pp 352–370.e2 Townsend JA, Wells MH (2019) Behavior guidance of the pediatric dental patient, in Pediatric dentistry. Elsevier, pp 352–370.e2
17.
Zurück zum Zitat Pérez-Lajarín L et al (2003) Marginal microleakage of two fissure sealants: a comparative study. J Dent Child 70(1):24–28 Pérez-Lajarín L et al (2003) Marginal microleakage of two fissure sealants: a comparative study. J Dent Child 70(1):24–28
18.
Zurück zum Zitat Burrow M, Makinson O (1990) Pits and fissures: remnant organic debris after acid-etching. ASDC J Dent Child 57(5):348–351PubMed Burrow M, Makinson O (1990) Pits and fissures: remnant organic debris after acid-etching. ASDC J Dent Child 57(5):348–351PubMed
24.
Zurück zum Zitat McCabe JF, Walls AW (2013) Applied dental materials. John Wiley & Sons McCabe JF, Walls AW (2013) Applied dental materials. John Wiley & Sons
25.
Zurück zum Zitat Penugonda B et al (1992) Bonding Ni-Cr alloy to tooth structure with adhesive resin cements. J Esthet Restor Dent 4:26–29CrossRef Penugonda B et al (1992) Bonding Ni-Cr alloy to tooth structure with adhesive resin cements. J Esthet Restor Dent 4:26–29CrossRef
26.
Zurück zum Zitat Styner D et al (1992) Bonding composite to glass lonomer with adhesive resin cements. J Esthet Restor Dent 4:13–15CrossRef Styner D et al (1992) Bonding composite to glass lonomer with adhesive resin cements. J Esthet Restor Dent 4:13–15CrossRef
30.
Zurück zum Zitat Gp H, JOSEPH T, JAYANTHI M (2004) Comparative evaluation of glass lonomer and resin based fissure sealant using noninvasive and invasive techniques-A SEM and microleakage study. J Indian Soc Pedo Prey Dent 22(2):56–62 Gp H, JOSEPH T, JAYANTHI M (2004) Comparative evaluation of glass lonomer and resin based fissure sealant using noninvasive and invasive techniques-A SEM and microleakage study. J Indian Soc Pedo Prey Dent 22(2):56–62
31.
Zurück zum Zitat Kwon HB, Park KT (2006) SEM and microleakage evaluation of 3 flowable composites as sealants without using bonding agents. Pediatr Dent 28(1):48–53PubMed Kwon HB, Park KT (2006) SEM and microleakage evaluation of 3 flowable composites as sealants without using bonding agents. Pediatr Dent 28(1):48–53PubMed
32.
Zurück zum Zitat Joshi K et al (2013) Comparative evaluation of two different pit & fissure sealants and a restorative material to check their microleakage–an in vitro study. J Int Oral Health 5(4):35PubMedPubMedCentral Joshi K et al (2013) Comparative evaluation of two different pit & fissure sealants and a restorative material to check their microleakage–an in vitro study. J Int Oral Health 5(4):35PubMedPubMedCentral
33.
Zurück zum Zitat Nurlatifah A, Eriwati Y, Indrani D (2018) The effect of the curing time of an ultra-high intensity LED curing unit on diametral tensile strength of packable composite resin. In: Journal of Physics: Conference Series. IOP Publishing Nurlatifah A, Eriwati Y, Indrani D (2018) The effect of the curing time of an ultra-high intensity LED curing unit on diametral tensile strength of packable composite resin. In: Journal of Physics: Conference Series. IOP Publishing
34.
Zurück zum Zitat Price RB (2017) Light curing in dentistry. Dental Clinics 61(4):751–778PubMed Price RB (2017) Light curing in dentistry. Dental Clinics 61(4):751–778PubMed
Metadaten
Titel
Evaluation of the effect of high-intensity light-curing device on micro-leakage of pits and fissure sealants
verfasst von
Hasan Alzoubi
Malek Rajab
Nada Bshara
Mohammed Bashier Almonakel
Publikationsdatum
01.12.2024
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 1/2024
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-023-03963-3

Weitere Artikel der Ausgabe 1/2024

Lasers in Medical Science 1/2024 Zur Ausgabe