Improvement of Neurovascular Imaging Using Ultra-High-Resolution Computed Tomography Angiography

verfasst von: Felix A. Ucar, Marius Frenzel, Andrea Kronfeld, Sebastian Altmann, Antoine P. Sanner, Mario Alberto Abello Mercado, Timo Uphaus, Marc A. Brockmann, Ahmed E. Othman

Erschienen in: Clinical Neuroradiology | Ausgabe 1/2024

Abstract

Objective

To evaluate diagnostic image quality of ultra-high-resolution computed tomography angiography (UHR-CTA) in neurovascular imaging as compared to normal resolution CT-angiography (NR-CTA).

Material and Methods

In this retrospective single-center study brain and neck CT-angiography was performed using an ultra-high-resolution computed tomography scanner (n = 82) or a normal resolution CT scanner (NR-CTA; n = 73). Ultra-high-resolution images were reconstructed with a 1024 × 1024 matrix and a slice thickness of 0.25 mm, whereas NR-CT images were reconstructed with a 512 × 512 matrix and a slice thickness of 0.5 mm. Three blinded neuroradiologists assessed overall image quality, artifacts, image noise, overall contrast and diagnostic confidence using a 4-point Likert scale. Furthermore, the visualization and delineation of supra-aortic arteries with an emphasis on the visualization of small intracerebral vessels was assessed using a cerebral vascular score, also utilizing a 4-point Likert scale. Quantitative analyses included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise and the steepness of gray value transition. Radiation exposure was determined by comparison of computed tomography dose index (CTDIvol), dose length product (DLP) and mean effective dose. Interrater agreement was evaluated via determining Fleiss-Kappa.

Results

Ultra-high-resolution CT-angiography (UHR-CTA) yielded excellent image quality with superior quantitative (SNR: p < 0.001, CNR: p < 0.001, steepness of gray value transition: p < 0.001) and qualitative results (overall image quality: 4 (Inter quartile range (IQR) = 4–4); p < 0.001, diagnostic confidence: 4 (IQR = 4–4); p < 0.001) compared to NR-CT (overall image quality: 3 (IQR = 3–3), diagnostic confidence: 3 (IQR = 3–4)). Furthermore, UHR-CT enabled significantly superior delineation and visualization of all vascular segments, from proximal extracranial vessels to the smallest peripheral cerebral branches (e.g., UHR-CTA PICA: 4 (3–4) vs. NR-CTA PICA: 3 (2–3); UHR-CTA P4: 4 (IQR = 3–4) vs. NR-CTA P4: 2 (IQR = 2–3); UHR-CTA M4: 4 (IQR = 4–4) vs. NR-CTA M4: 3 (IQR = 2–3); UHR-CTA A4: 4 (IQR = 3–4) vs. NR-CTA A4: 2 (IQR = 2–3); all p < 0.001). Noteworthy, a reduced mean effective dose was observed when applying UHR-CT (NR-CTA: 1.8 ± 0.3 mSv; UHR-CTA: 1.5 ± 0.5 mSv; p < 0.001).

Conclusion

Ultra-high-resolution CT-angiography improves image quality in neurovascular imaging allowing the depiction and evaluation of small peripheral cerebral arteries. It may thus improve the detection of pathologies in small cerebrovascular lesions and the resulting diagnosis.
Abkürzungen
ICA
Internal carotid artery
AICA
Anterior inferior cerebellar artery
CNR
Contrast to noise ratio
CT
Computed tomography
CTA
Computed tomography angiography
CTDIvol
Computed tomography dose index
DLP
Dose length product
MCA
Middle cerebral artery
NR-CT
Normal resolution computed tomography
PICA
Posterior inferior cerebellar artery
ROI
Region of interest
SCA
Superior cerebellar artery
SNR
Signal to noise ratio
UHR
Ultra-high-resolution

Introduction

Noninvasive techniques have become highly relevant in neurovascular imaging, and computed tomography angiography (CTA) nowadays represents a key component therein. Computed tomography (CT) is of crucial importance in neuroradiological imaging and has excelled in clinical routine due to its ubiquitous availability in cases of emergency while maintaining high diagnostic accuracy. Main goals in neurovascular imaging are rapid volume coverage with the ability to detect pathologies in small diameter vessels at high sensitivity and specificity. Normal resolution CTA (NR-CTA) has been the working horse in neurovascular imaging for decades, but it is generally limited in the delineation of anatomical small diameter vessels and small cerebrovascular lesions due to its limited spatial resolution. The most recent developments in CT technology and reconstruction algorithms enabled radiologists to acquire image data with increased, ultra-high-resolution [1]. There are currently two methods for generating ultra-high-resolution CTAs: photon counting technology [2, 3] and the energy-integrated CT system with very small detector elements investigated here. Recently, one of the first UHR-CTs with advanced detector elements (element size, 0.25 mm at isocenter, superfine detector grids) and a small focal spot size (smallest size 0.4 × 0.5 mm) was introduced and implemented into the clinical routine to further improve neurovascular imaging. First technical reports have demonstrated the capability of UHR-CT to improve image quality in temporal bone imaging [4], coronary artery imaging [5, 6] and thoracic imaging [7, 8]; however, the capability of UHR-CT in comparison to NR-CT in neurovascular imaging has not been investigated thoroughly. With this novel technology at hand we hypothesized that the UHR-CTA could provide superior image qualities compared to NR-CTA, hereby adding value to the visualization of smaller vessels and cerebrovascular lesions. Hence, the aim of this study was to comprehensively evaluate the image quality metrics and the diagnostic possibilities of vascular imaging of UHR-CTA compared to NR-CTA.

Material and Methods

Study Population

This retrospective study was approved, and written informed consent was waived by our local ethics committee. All methods were performed in accordance with the 2008 version of the Declaration of Helsinki.
The study population included consecutive adult patients who presented with acute neurologic symptoms and received a diagnostic UHR-CTA or NR-CTA at our department from September 2021 to December 2022. Exclusion criteria were distinct motion artifacts, beam-hardening artifacts and an insufficient contrast due to venous overlay (Fig. 1).

CT Examination and Scanner Systems

The UHR-CT system (Aquilion Precision; Canon Medical Systems Corporation; Japan) featured a detector element size of 0.25 mm, a focal spot size of 0.4 × 0.5 mm, a beam collimation of 0.25 × 160 mm rows with 1792 channels and a spatial resolution of up to 50 lp/cm. The clinically optimized parameters of the CTA protocol consisted of a smallest focal spot size of 0.8 × 1.3 mm, a detailed pitch of 0.569, and a tube voltage of 120 kV, a field of view of 180 mm, and a rotation time of 0.35 s per rotation. The acquired images were reconstructed using a 1024 × 1024 matrix.
The NR-CT scanner featured a detector element size of 0.5 mm, a beam collimation of 0.5 × 32 mm rows, and a maximum spatial resolution of 18 lp/cm. The parameters of the CTA protocol consisted of a focal spot size of 0.8 × 1.3 mm, a helical pitch of 0.844, a tube voltage of 120 kVp, a field of view of 180 mm, and a rotation time of 0.5 s per rotation. The focal spot size was 1.6 × 1.4 mm. Images were reconstructed using a matrix of 512 × 512.
Both CT scanners used the auto-exposure control (AEC) with automated current adjustment to generate a radiation dose as low as reasonably achievable.
For both protocols the nonionic contrast agent iopromide (Ultravist-370; Bayer Healthcare, Germany) was injected using a high-pressure syringe system for advanced clinical CT-imaging procedures (Accutron CT‑D; Medtron; Saarbrücken, Germany) and 65 ml of the prewarmed contrast agent was administered via a peripheral venous catheter in the antecubital fossa at a flow rate of 5 ml/s, immediately followed by a 60 ml saline bolus.
According to our standards and for sufficient comparability, a monitoring region of interest (ROI) was placed in the ascending aorta to consolidate arterial contrast while minimizing venous contamination. Timing was optimized using automatic trigger acquisition and enhancement threshold selection. Acquisition started after reaching a threshold of 180 HU (Hounsfield units) in the aortic arch.

Image Reconstruction and Processing

The axial source images of UHR-CTA (slice thickness 0.25 mm) were reconstructed in 3 planes with slice thicknesses of 0.25 mm, 1 mm and 3 mm, respectively and a reconstruction matrix of 1024 × 1024 pixels. The adaptive iterative three-dimensional dose reduction tool AIDR 3D standard (Canon Medical Systems Corporation) with an FC41 soft tissue kernel adapted to UHR was used as a reconstruction algorithm.
The NR-CTA source images with slice thicknesses of 0.5 mm were reconstructed in 1 mm in coronal and sagittal reformation from a 512 × 512 pixels matrix using a filtered back projection with an FC04 soft tissue kernel.

Qualitative Evaluation

The acquired data were transferred to a workstation equipped with additional modules for neuroradiological vascular analysis (Sectra Workstation, Linköping, Sweden).
Overall image quality, diagnostic confidence, overall contrast, noise and artefacts were evaluated by three radiologists (blinded data, A.M, and A.S: both 5 years of experience in neurovascular imaging and A.O: more than 10 years of experience) on a 4-point Likert scale with 4 being best (Table 1). For a dedicated evaluation of cerebral vasculature, we developed a cerebral vessel score (Table 2) which was applied to the following vessels: internal carotid artery (ICA), vertebral arteries (VA), posterior inferior cerebellar artery (PICA), anterior inferior cerebellar artery (AICA), superior cerebellar artery (SCA) and the anterior, middle and posterior cerebral artery (ACA, MCA, PCA, respectively) and their subsegments. For training and reaching a standardized consensus regarding the 4‑point Likert scale, images from 20 patients, who were not included in the study were used.
Table 1
Likert scale for qualitative analysis
Grading
Image quality
Vascular contrast
Artefacts
Diagnostic confidence
1
Evident limitations in the vessel/wall/lumen definition due to strong image noise
Homogeneous contrast throughout all vessel sections
Present and affecting image evaluation
Unacceptable
2
Good, with minimal limitations in the vessel wall/lumen definition due to moderate image noise
Good contrast—Good distribution of the contrast agent and contrasting of the vascular course
Present and affecting vascular structures
Suboptimal
3
Very good, with well-preserved vessel wall definition and well-preserved delineated contour due to minimal image noise
Average contrast—Partially inhomogeneous distribution and contrasting of the vascular course
Present but not affecting visualization of vascular structures
Average
4
Excellent, with sharp vessel wall and well-delineated vessel contours due to poor image noise
Poor contrast—Distribution of the contrast agent and contrasting of the vascular course
None
Above average
Table 2
Cerebral vessel score
Vessel score
Description
4—excellent
Sharp vessel wall and well-delineated contour of the vessel
3—very good
Well-preserved vessel wall definition and well-preserved delineated contour
2—good
Minimal limitations in the vessel wall/lumen definition
1—limited
Evident limitations in the vessel/wall/lumen definition with diagnostic influence

Quantitative Evaluation

For quantitative analysis, a board certified radiologist (blinded data, with 5 years of experience in neuroradiology) exported images from the Vitrea workstation (Canon Medical Systems, Otawara) as DICOM formats to a workstation including a MATLAB tool (R2017b, The MathWorks, Natick, MA).
The measurement of the steepness of gray value transition was performed in two vessel sections: extracranial ICA and intracranial basilar arteries (BA). Due to reproducibility and comparability reasons, measurements were taken exactly on the same anatomical vessel position. In the presence of hemodynamically relevant stenoses, calcified plaques, compromising surrounding processes or occlusion of the examined vessel, the contralateral side was used. Objective image quality parameters for examiner-independent assessment of contrast and delineation were determined as follows: three different parameters were gathered automatically, i.e., analysis of the distance between 25% and 75% of the maximum grey value in mm, difference in HU and steepest slope between the vessel and the perivascular tissue.
We selected an image region containing the vessel of interest, and thereby, the vessel region and other tissue types were automatically detected due to their high HU. The vessel region center was thus calculated, and a profile was drawn from that center through each voxel mapping to the vessel region border. Afterwards, the upper and lower baseline signal intensities (SI) as well as their 25% SI and 75% SI and their corresponding profile positions were determined for each profile. Furthermore, the slope of the transition between gray values inside and outside the vessel were calculated using linear regression. In order to reduce partial volume effects, only median parameters of the profiles showing 20% of the steepest slope values were processed.
To quantitatively evaluate additional image quality parameters, noise, SNR and CNR were analyzed in the ICA and BA.
The determination of the local noise in the immediate vicinity of the evaluated vessel was based on previous reports [9, 10] and hence we aimed at the determination of noise that remains unaffected by tissue structures or gray value trends. Consequently, a sliding window of 5 mm × 5 mm was applied to the previously selected ROI. If tissue transitions were in the actual position of the sliding window, the respective position was excluded, and the window moved to the next position. If no tissue transitions were included, the region was detrended by a 2D-polynomial fit of second order [11] and the standard deviation of the gray values was calculated. The minimum standard deviation of the complete ROI of all window positions was used for further SNR and CNR calculations.
The SNR was calculated as the signal intensity of the upper baseline, divided by the noise value, the CNR as the difference of the signal intensity of the upper and lower baseline, divided by the noise value. The quantitative analysis is illustrated in Fig. 2.

Radiation Dose

CDTIvol and dose length product (DLP) were reported and effective dose was estimated by multiplying DLP with the conversion factor for neck-brain CTA (0.0031 mSv *mGy-1 *cm-1; adapted for CTDIvol values of a 16 cm head phantom) [10].

Statistical Analysis

Statistical analysis as well as the illustrations were carried out using R 4.1.3 (R Foundation for Statistical Computing, Vienna, Austria).
Mean and standard deviation are reported for continuous variables. Median and frequencies are reported for ordinal variables. Student’s t‑test was conducted for comparing continuous variables and Wilcoxon-signed rank test for comparing ordinal variables. A two-tailed p-value of < 0.05 was considered statistically significant.
Interobserver variability was determined based on Fleiss-kappa. Kappa values of up to 0.20 were considered as slight agreement, 0.21–0.30 as poor agreement, 0.31–0.40 as fair agreement, 0.41–0.50 as moderate agreement, 0.51–0.70 as good agreement and > 0.7 as almost perfect agreement.

Results

Patient Characteristics

We identified 177 patients to be eligible for inclusion in the study but 20 patients were excluded due to severe artifacts (movement or beam hardening), insufficient contrast or due to venous contamination, leading to a final study cohort of n = 155 (M = 64; F = 91; age = 67.2 ± 11.3 years). The two sub-cohorts consisted of NR-CT: n = 73 (F = 49; M = 24) and UHR-CT n = 82 (F = 42; M = 40). Of the patients in the NR-CTA data set 12 were excluded (3 patients = severe metal artifacts; 1 patient = severe motion artifact and 8 patients = insufficient arterial contrast) and 8 patients of the UHR-CTA data set were excluded (7 patients due to insufficient arterial contrast and 1 patient due to metal artifacts).

Qualitative Evaluation

In comparison to NR-CTA, UHR-CTA showed significantly superior overall image quality. Briefly, UHR-CTA revealed higher image quality (p < 0.001), lower subjective image noise (p < 0.001), less artifacts (p < 0.001), higher overall contrast (p < 0.001) and higher diagnostic confidence (p < 0.001). Dedicated vessel evaluation showed superior neurovascular delineation and visualization of all vessel segments from proximal to distal for UHR-CTA compared to NR-CTA (PICA: UHR-CTA = 4 (3–4) vs NR-CTA = 3 (2–3); P4: UHR-CTA = 4 (3–4) vs NR-CTA = 2 (2–3); M4: UHR-CTA = 4 (4–4) vs NR-CTA = 3 (2–3); A4: UHR-CTA = 4 (3–4) vs NR-CTA = 2 (2–3); all p < 0.001). Medians and frequencies of the subjective assessment are demonstrated in Fig. 3 and Table 3. Interreader agreement between the three readers was good to almost perfect for image quality evaluation (kappa: 0.7, 0.6, 0.7 and 0.7 for artifacts, image noise, overall image quality and overall, respectively) and good for evaluating the delineation of the small, intracerebral arteries (kappa: 0.7).
Table 3
Quality statistics across raters: Compared medians, interquartile range and p-values
Metric
NR-CT
median (IQR)
UHR-CT
median (IQR)
P value
Overall image quality
3 (3–3)
4 (4–4)
p < 0.001
Noise
3 (3–3)
4 (3–4)
p < 0.001
Artefacts
3 (3–3)
4 (4–4)
p < 0.001
Overall contrast
4 (3–4)
4 (4–4)
p < 0.001
Diagnostic confidence
3 (3–4)
4 (4–4)
p < 0.001
Carotid arteries
4 (3–4)
4 (4–4)
p < 0.001
Vertebral arteries
3 (3–4)
4 (4–4)
p < 0.001
Basilar artery
4 (3–4)
4 (4–4)
p < 0.001
PICA
3 (2–3)
4 (4–4)
p < 0.001
AICA
3 (2–3)
4 (3–4)
p < 0.001
SCA
3 (2–3)
3 (3–4)
p < 0.001
P1
4 (3–4)
4 (4–4)
p < 0.001
P2
3 (3–4)
4 (4–4)
p < 0.001
P3
3 (2–3)
4 (3–4)
p < 0.001
P4
2 (2–3)
4 (3–4)
p < 0.001
M1
4 (3–4)
4 (4–4)
p < 0.001
M2
3 (3–4)
4 (4–4)
p < 0.001
M3
3 (3–4)
4 (3–4)
p < 0.001
M4
3 (2–3)
4 (3–4)
p < 0.001
A1
4 (3–4)
4 (4–4)
p < 0.001
A2
3 (3–4)
4 (4–4)
p < 0.001
A3
3 (2–3)
4 (4–4)
p < 0.001
A4
2 (2–3)
4 (3–4)
p < 0.001
PICA posterior inferior cerebellar artery, AICA anterior inferior cerebellar artery, SCA superior cerebellar artery, P1-4 posterior cerebral artery sub-segments, M1-4 middle cerebral artery sub-segments, A1-4 anterior cerebral artery sub-segments, IQR interquartile range, UHR-CT ultra-high-resolution computed tomography, NR-CT normal resolution computed tomography
A clear depiction and delineation of small, peripheral vessels in a patient example is given in Fig. 4, and the remarkable superiority of UHR-CT in the visualization of peripheral and small vessel branches and their delineation is demonstrated in volume rendering (Fig. 5). The improved image quality of the vertebrobasilar area is also substantial: VA: UHR-CTA = 4 (4–4) vs NR-CTA = 3 (3–4) PICA: UHR-CTA = 4 (3–4) vs NR-CTA = 3 (2–3); AICA: UHR-CTA = 4 (3–4) vs NR-CTA = 3 (2–3). The apparent differences in delineation of peripheral cerebral vessels are illustrated in Fig. 5.

Quantitative Evaluation

The SNR and CNR were calculated for two types of arteries (ICA, BA) per patient, and their distributions were illustrated using a boxplot graph (Fig. 6). UHR-CTA showed significantly increased SNR (from NR-CT = 32.04 to UHR-CT = 38.20; p < 0.001) and CNR (from NR-CT = 31.3 to UHR-CT = 39.2; p < 0.001).
The slope of gray value transitions between intravascular and perivascular fibrous tissue for the internal carotid artery was steeper and increased (NR-CT = 307.2 HU/mm and UHR-CT = 432.4 HU/mm; p < 0.001). Consequently, the difference between 25% and 75% in HU was also increased (NR-CTA = 290.3 HU and UHR-CTA = 378.9 HU, p < 0.02), as well as the corresponding slope for the basilar artery (NR-CT = 307.2 HU/mm and UHR-CT = 378.4 HU/mm; p < 0.001) and the corresponding difference (NR-CT = 206.2 HU and UHR-CT = 251.3 HU; p < 0.02). All aforementioned metrics were analyzed and illustrated as boxplot graphs for BA and ICA (Fig. 6).

Radiation Dose

The CTDIvol of NR-CT was 57 ± 7.2 mGy and the DLP was 563.2 ± 115.7 mGy*cm, resulting in a mean effective dose of 1.9 ± 0.3 mSv. In contrast, the mean CDTIvol of UHR-CT was significantly lower with 12.17 ± 4.36 mGy, the DLP was at an average lower with 486.3 ± 138.3 mGy*cm, which resulted in a mean effective dose of 1.5 ± 0.3 mSv. Radiation dose was significantly lower for UHR-CTA as compared to NR-CT (p < 0.001).

Discussion

The purpose of our study was to assess the image quality and dose exposure of the UHR-CTA compared to NR-CT and to evaluate the potential benefit for routine application.
First technical reports have already indicated feasibility of UHR-CTA [12, 13], albeit without a comparative patient cohort study. The additional value of UHR-CT has been reported for studies focusing on other body regions, and its improved diagnostic ability to visualize even very small structures such as coronary arteries [14], the artery of Adamkiewicz [15, 16] or collaterals in moyamoya disease [17] has been highlighted.
The relevance of UHR imaging in clinical routine is expanding due to the implementation of two novel detector technologies, which provide ultra-high-resolution images (photon counting CT technology and UHR-CT with superfine detector elements). In particular, ultra-high-resolution vascular imaging bears new perspectives and is consistently in the focus of current research and frequently discussed [2, 3, 18].
The results of this study show that UHR-CTA provides excellent subjective and objective image quality as well as excellent visualization of small vascular and perivascular tissues and thus is superior to NR-CT. Data analysis yielded higher SNR and CNR as well as contour sharpness for UHR-CT. Although the spatial resolution and image quality were higher, UHR-CT was associated with a slight but significantly lower radiation dose compared to NR-CT. The reduction in radiation dose may be attributed to the new UHR detector system with a relatively low electronic noise [19], despite its superior resolution.
Due to a remarkably increased image quality in UHR-CTA, the identification of small vascular lesions is facilitated, and the resulting images simultaneously present with high diagnostic content and low noise. The qualitative and diagnostic improvement may be of value in many clinical situations. The high image quality and diagnostic confidence of UHR datasets could also contribute to a more accurate description of the configuration and to the detection of diminutive abnormalities, such as calcifications, daughter aneurysms, intranidal aneurysms and therapeutically relevant branching vessels. It may allow a clear distinction between intradurak and extradural localization of aneurysms; however, even with greatly improved image quality digital subtraction angiography still remains the gold standard in cerebrovascular imaging. Whereas increasing image resolution and improvements in SNR normally results in an increase of radiation doses, the UHR-CT system used in the underlying study provides lower radiation than the hitherto used NR-CT system, despite improved image quality. In line with the ALARA (as low as reasonably achievable) principle the use of UHR-CTA may enable an improved noninvasive, preinterventional planning. A precise planning based on this type of CT data may contribute to preferred diagnostic projections and may lead to shorter fluoroscopy times in diagnostic subtraction angiography. Additionally, patients would also benefit from a reduced radiation exposure. Ultra-high-resolution imaging of the cerebral vessels was achieved with 7T TOF MRA [2022] and cone beam CT [23] with very promising results, allowing better visualization of the small and peripheral vessels and their perivascular tissue.
Furthermore, follow-up imaging after intracranial stenting may benefit from increased resolution and image quality. Another advantage of UHR-CTA may be a more precise evaluation of postinterventional, extracranial stent positions and the follow-up imaging. In particular, carotid stent and carotid endarterectomy monitoring may be facilitated, and complications such as intimal proliferation and restenosis of stents may be identified earlier, resulting in a quicker therapeutic response. This should be considered in studies combining UHR-CTAs with metal artefact reduction algorithms using homogeneous cohorts of stent-treated patients.
The advancement of clinical material science in mechanical thrombectomy may lead to an expansion of treatment indications in peripheral arterial occlusions in the future and thus, the here described improved delineation of vascular subsegments, especially the peripheral subsegments (M3, M4, P2, P3, and P4) may render these structures more accessible for both diagnosis and treatment [24, 25]. These results of improved visualization of peripheral vessel segments may appear particularly relevant in the context of current multicenter randomized treatment trials for distal thrombectomy.
Improved imaging, particularly of the vertebrobasilar arteries and cerebellar arteries, can facilitate the diagnosis of potentially life-threatening occlusions of these vessels and of diagnostically challenging vascular diseases such as Wallenberg syndrome.
The use of UHR-CT may enable the timely diagnosis of early stages of vascular aging, characterized by fatty streaks that accumulate during of the molecular pathomechanism in atherosclerosis. Hence, atherosclerotic plaques may be defined more accurately, resulting in a precise graduation of vessel stenosis. In particular, the differentiation of subtotal stenosis from vessel occlusion may be optimized, hereby aiding treatment decisions.
In addition, small vessel changes such as intimal flaps, arterial fenestrations, fibromuscular dysplasia or carotid webs could become amenable to diagnosis in CT imaging. Summing up, our results confirm the value of the UHR technique in clinical use and may also excite further pathology-associated studies and a comparative to evaluate the envisaged improvement.
We were limited by the retrospective study design and the small number of subjects including a possible selection bias. The lacking intraindividual comparison between NR-CTA and UHR-CTA is a further limitation of this study. The potentially obvious distinction between the image data from the new device and the old CT system could have caused reader bias, which we attempted to counteract with a randomized procedure and initial consensus training. Furthermore, our study lacks homogeneous pathological groups which represents a further limitation. Beyond that, the small sample size does not allow a generalization of our conclusions yet, and therefore, future prospective studies with larger cohorts are needed.

Conclusion

Ultra-high-resolution CT angiography improves image quality in neurovascular imaging allowing the depiction and evaluation of small peripheral cerebral arteries. It may thus improve the detection of pathologies in small cerebrovascular lesions and the resulting diagnosis.

Declarations

Conflict of interest

F.A. Ucar, M. Frenzel, A. Kronfeld, S. Altmann, A. Sanner, M.A.A. Mercado, T. Uphaus, M.A. Brockmann and A.E. Othman declare that they have no competing interests. A.E. Othman and M.A. Brockmann report a relationship with Canon Medical Corporation that includes speaking and lecture fees.

Ethical standards

This retrospective study was performed in line with the principles of the Declaration of Helsinki, it has been approved by the local ethics committee of Rhineland Palatinate, written consent by the patients was waived in view of the retrospective nature of the study and all procedures performed were part of the routine care.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

e.Med Neurologie & Psychiatrie

Kombi-Abonnement

Mit e.Med Neurologie & Psychiatrie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

e.Med Neurologie

Kombi-Abonnement

Mit e.Med Neurologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes, den Premium-Inhalten der neurologischen Fachzeitschriften, inklusive einer gedruckten Neurologie-Zeitschrift Ihrer Wahl.

Weitere Produktempfehlungen anzeigen
Literatur
2.
Zurück zum Zitat Mergen V, et al. Ultra-high-resolution coronary CT angiography with photon-counting detector CT: feasibility and image characterization. Invest Radiol. 2022;57(12):780–8.CrossRefPubMedPubMedCentral Mergen V, et al. Ultra-high-resolution coronary CT angiography with photon-counting detector CT: feasibility and image characterization. Invest Radiol. 2022;57(12):780–8.CrossRefPubMedPubMedCentral
3.
4.
Zurück zum Zitat Ohara A, et al. Improved image quality of temporal bone CT with an ultrahigh-resolution CT scanner: clinical pilot studies. Jpn J Radiol. 2020;38(9):878.CrossRefPubMedPubMedCentral Ohara A, et al. Improved image quality of temporal bone CT with an ultrahigh-resolution CT scanner: clinical pilot studies. Jpn J Radiol. 2020;38(9):878.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Latina J, et al. Ultra-high-resolution coronary CT angiography for assessment of patients with severe coronary artery calcification: initial experience. Radiol Cardiothorac Imaging. 2021;3(4):e210053.CrossRefPubMedPubMedCentral Latina J, et al. Ultra-high-resolution coronary CT angiography for assessment of patients with severe coronary artery calcification: initial experience. Radiol Cardiothorac Imaging. 2021;3(4):e210053.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Motoyama S, et al. Ultra-high-resolution computed tomography angiography for assessment of coronary artery stenosis. Circ J. 2018;82(7):1844–51.CrossRefPubMed Motoyama S, et al. Ultra-high-resolution computed tomography angiography for assessment of coronary artery stenosis. Circ J. 2018;82(7):1844–51.CrossRefPubMed
7.
Zurück zum Zitat Shanbhag SM, et al. Prototype ultrahigh-resolution computed tomography for chest imaging: initial human experience. J Comput Assist Tomogr. 2019;43(5):805–10.CrossRefPubMed Shanbhag SM, et al. Prototype ultrahigh-resolution computed tomography for chest imaging: initial human experience. J Comput Assist Tomogr. 2019;43(5):805–10.CrossRefPubMed
8.
Zurück zum Zitat Ohno Y, et al. Comparison of lung CT number and airway dimension evaluation capabilities of ultra-high-resolution CT, using different scan modes and reconstruction methods including deep learning reconstruction, with those of multi-detector CT in a QIBA phantom study. Eur Radiol. 2022; https://doi.org/10.1007/s00330-022-08983-1.CrossRefPubMed Ohno Y, et al. Comparison of lung CT number and airway dimension evaluation capabilities of ultra-high-resolution CT, using different scan modes and reconstruction methods including deep learning reconstruction, with those of multi-detector CT in a QIBA phantom study. Eur Radiol. 2022; https://​doi.​org/​10.​1007/​s00330-022-08983-1.CrossRefPubMed
9.
Zurück zum Zitat Anam C, et al. An improved method of automated noise measurement system in CT images. J Biomed Phys Eng. 2021;11(2):163.PubMedPubMedCentral Anam C, et al. An improved method of automated noise measurement system in CT images. J Biomed Phys Eng. 2021;11(2):163.PubMedPubMedCentral
10.
Zurück zum Zitat Chun M, Choi YH, Kim JH. Automated measurement of CT noise in patient images with a novel structure coherence feature. Phys Med Biol. 2015;60(23):9107.CrossRefPubMed Chun M, Choi YH, Kim JH. Automated measurement of CT noise in patient images with a novel structure coherence feature. Phys Med Biol. 2015;60(23):9107.CrossRefPubMed
11.
Zurück zum Zitat Dobbins JT III, et al. Intercomparison of methods for image quality characterization. II. Noise power spectruma. Med Phys. 2006;33(5):1454.CrossRefPubMed Dobbins JT III, et al. Intercomparison of methods for image quality characterization. II. Noise power spectruma. Med Phys. 2006;33(5):1454.CrossRefPubMed
12.
Zurück zum Zitat Ucar FA, et al. Feasibility of ultra-high resolution supra-aortic CT angiography: an assessment of diagnostic image quality and radiation dose. Tomography. 2021;7(4):711–20.CrossRefPubMedPubMedCentral Ucar FA, et al. Feasibility of ultra-high resolution supra-aortic CT angiography: an assessment of diagnostic image quality and radiation dose. Tomography. 2021;7(4):711–20.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Shanbhag SM, Chen MY. Ultra-high-resolution coronary CT angiography: the “final frontier”—are we there yet? Radiol Cardiothorac Imaging. 2021;3(4):e210196.CrossRefPubMedPubMedCentral Shanbhag SM, Chen MY. Ultra-high-resolution coronary CT angiography: the “final frontier”—are we there yet? Radiol Cardiothorac Imaging. 2021;3(4):e210196.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Hino T, et al. Detectability of the artery of Adamkiewicz on computed tomography angiography of the aorta by using ultra-high-resolution computed tomography. Jpn J Radiol. 2020;38(7):658–65.CrossRefPubMed Hino T, et al. Detectability of the artery of Adamkiewicz on computed tomography angiography of the aorta by using ultra-high-resolution computed tomography. Jpn J Radiol. 2020;38(7):658–65.CrossRefPubMed
16.
Zurück zum Zitat Yoshioka K, et al. Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study. Neuroradiology. 2018;60(1):109–15.CrossRefPubMed Yoshioka K, et al. Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study. Neuroradiology. 2018;60(1):109–15.CrossRefPubMed
17.
Zurück zum Zitat Fukushima Y, et al. Evaluation of moyamoya disease in CT angiography using ultra-high-resolution computed tomography: application of deep learning reconstruction. Eur J Radiol. 2022;151:110294.CrossRefPubMed Fukushima Y, et al. Evaluation of moyamoya disease in CT angiography using ultra-high-resolution computed tomography: application of deep learning reconstruction. Eur J Radiol. 2022;151:110294.CrossRefPubMed
18.
Zurück zum Zitat Dangelmaier J, et al. Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair. Eur Radiol. 2018;28(8):3318–25.CrossRefPubMedPubMedCentral Dangelmaier J, et al. Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair. Eur Radiol. 2018;28(8):3318–25.CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Boedeker K. Aquilion Precision ultra-high resolution CT:quantifying diagnostic image quality. 2018. Boedeker K. Aquilion Precision ultra-high resolution CT:quantifying diagnostic image quality. 2018.
20.
Zurück zum Zitat Grochowski C, Staśkiewicz G. Ultra high field TOF-MRA: a method to visualize small cerebral vessels. 7T TOF-MRA sequence parameters on different MRI scanners—literature review. Neurol Neurochir Pol. 2017;51(5):411–8.CrossRefPubMed Grochowski C, Staśkiewicz G. Ultra high field TOF-MRA: a method to visualize small cerebral vessels. 7T TOF-MRA sequence parameters on different MRI scanners—literature review. Neurol Neurochir Pol. 2017;51(5):411–8.CrossRefPubMed
21.
Zurück zum Zitat Harteveld AA, et al. 7‑T MRI in cerebrovascular diseases: challenges to overcome and initial results. Top Magn Reson Imaging. 2016;25(2):89–100.CrossRefPubMed Harteveld AA, et al. 7‑T MRI in cerebrovascular diseases: challenges to overcome and initial results. Top Magn Reson Imaging. 2016;25(2):89–100.CrossRefPubMed
22.
Zurück zum Zitat Kraff O, et al. MRI at 7 Tesla and above: demonstrated and potential capabilities. J Magn Reson Imaging. 2015;41(1):13–33.MathSciNetCrossRefPubMed Kraff O, et al. MRI at 7 Tesla and above: demonstrated and potential capabilities. J Magn Reson Imaging. 2015;41(1):13–33.MathSciNetCrossRefPubMed
23.
Zurück zum Zitat Simoni A, et al. Innovative tool for automatic detection of arterial stenosis on cone beam computed tomography. Appl Sci. 2023;13(2):805.CrossRef Simoni A, et al. Innovative tool for automatic detection of arterial stenosis on cone beam computed tomography. Appl Sci. 2023;13(2):805.CrossRef
24.
Zurück zum Zitat Stampfl S, et al. Initial experience with a new distal intermediate and aspiration catheter in the treatment of acute ischemic stroke: clinical safety and efficacy. J Neurointervent Surg. 2016;8(7):714–8.CrossRef Stampfl S, et al. Initial experience with a new distal intermediate and aspiration catheter in the treatment of acute ischemic stroke: clinical safety and efficacy. J Neurointervent Surg. 2016;8(7):714–8.CrossRef
25.
Zurück zum Zitat Kurre W, et al. Stent retriever thrombectomy of small caliber intracranial vessels using pREset LITE: safety and efficacy. Clin Neuroradiol. 2017;27(3):351–60.CrossRefPubMed Kurre W, et al. Stent retriever thrombectomy of small caliber intracranial vessels using pREset LITE: safety and efficacy. Clin Neuroradiol. 2017;27(3):351–60.CrossRefPubMed
Metadaten
Titel
Improvement of Neurovascular Imaging Using Ultra-High-Resolution Computed Tomography Angiography
verfasst von
Felix A. Ucar
Marius Frenzel
Andrea Kronfeld
Sebastian Altmann
Antoine P. Sanner
Mario Alberto Abello Mercado
Timo Uphaus
Marc A. Brockmann
Ahmed E. Othman
Publikationsdatum
13.10.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Neuroradiology / Ausgabe 1/2024
Print ISSN: 1869-1439
Elektronische ISSN: 1869-1447
DOI
https://doi.org/10.1007/s00062-023-01348-1

Weitere Artikel der Ausgabe 1/2024

Clinical Neuroradiology 1/2024 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.