Skip to main content
Erschienen in: Skeletal Radiology 4/2024

13.11.2023 | Review Article

Magnetic resonance imaging quality in the context of a knee-spanning external fixator placed inside the MR bore: a literature review

verfasst von: Aaron J. Marcel, Joshua S. Green, Jack Porrino, Lee D. Katz, Michael J. Medvecky

Erschienen in: Skeletal Radiology | Ausgabe 4/2024

Einloggen, um Zugang zu erhalten

Abstract

After emergent assessment of potentially limb-threatening injuries in knee dislocation or multi-ligament knee injury patients, magnetic resonance imaging is necessary to visualize ligamentous structures and plan for soft tissue repair. However, the application of a knee-spanning external fixator may introduce artifact and reduce overall image quality, which can limit the evaluation of soft tissue injury. As a result, the utility of MRI in the context of a knee-spanning external fixator has been called into question. Signal-to-noise ratio, contrast-to-noise ratio, and qualitative scales have been used to assess image quality of MRI in the context of a knee-spanning external fixator. Despite the potential for artifact, studies have demonstrated that useful diagnostic information may be obtained from MRI in the presence of an external fixator. This review examines the general principles of anatomical assessment, magnetic field strength, device composition and design, radiofrequency coil use, and MRI sequences and artifact reduction as they pertain to MRI in the presence of a knee-spanning external fixator.
Literatur
1.
Zurück zum Zitat Maslaris A, Brinkmann O, Bungartz M, Krettek C, Jagodzinski M, Liodakis E. Management of knee dislocation prior to ligament reconstruction: what is the current evidence? Update of a universal treatment algorithm. Eur J Orthop Surg Traumatol. 2018;28(6):1001–15.CrossRefPubMed Maslaris A, Brinkmann O, Bungartz M, Krettek C, Jagodzinski M, Liodakis E. Management of knee dislocation prior to ligament reconstruction: what is the current evidence? Update of a universal treatment algorithm. Eur J Orthop Surg Traumatol. 2018;28(6):1001–15.CrossRefPubMed
2.
Zurück zum Zitat Cramer C, Frosch KH. External fixator for temporary stabilization of complex periarticular knee fractures. Oper Orthop Traumatol. 2020;32(5):410–20.CrossRefPubMed Cramer C, Frosch KH. External fixator for temporary stabilization of complex periarticular knee fractures. Oper Orthop Traumatol. 2020;32(5):410–20.CrossRefPubMed
3.
Zurück zum Zitat Fanelli GC. Multiple ligament injured knee: initial assessment and treatment. Clin Sports Med. 2019;38(2):193–8.CrossRefPubMed Fanelli GC. Multiple ligament injured knee: initial assessment and treatment. Clin Sports Med. 2019;38(2):193–8.CrossRefPubMed
4.
Zurück zum Zitat Goodier WD, Calder PR. External fixation for the correction of adult post-traumatic deformities. Injury. 2019;50 (Suppl 1):S36-44.CrossRefPubMed Goodier WD, Calder PR. External fixation for the correction of adult post-traumatic deformities. Injury. 2019;50 (Suppl 1):S36-44.CrossRefPubMed
5.
Zurück zum Zitat Simpson AHRW, Robiati L, Jalal MMK, Tsang STJ. Non-union: indications for external fixation. Injury. 2019;50(Suppl 1):S73–8.CrossRefPubMed Simpson AHRW, Robiati L, Jalal MMK, Tsang STJ. Non-union: indications for external fixation. Injury. 2019;50(Suppl 1):S73–8.CrossRefPubMed
8.
Zurück zum Zitat Ryan S, Moon AS, Gordon M, Flacke S, Soni S, Salzler MJ, et al. External fixation devices within the magnetic resonance imaging bore: a safety and radiologic analysis. J Orthop Trauma. 2021;35(1):e25-30.CrossRefPubMed Ryan S, Moon AS, Gordon M, Flacke S, Soni S, Salzler MJ, et al. External fixation devices within the magnetic resonance imaging bore: a safety and radiologic analysis. J Orthop Trauma. 2021;35(1):e25-30.CrossRefPubMed
10.
Zurück zum Zitat Morandi MM, Simoncini A, Hays C, Garrett J, Barton RS, Chen A, et al. Optimal configuration for stability and magnetic resonance imaging quality in temporary external fixation of tibial plateau fractures. Orthop Traumatol Surg Res. 2020;106(7):1405–12.CrossRefPubMed Morandi MM, Simoncini A, Hays C, Garrett J, Barton RS, Chen A, et al. Optimal configuration for stability and magnetic resonance imaging quality in temporary external fixation of tibial plateau fractures. Orthop Traumatol Surg Res. 2020;106(7):1405–12.CrossRefPubMed
11.
Zurück zum Zitat Elsissy P, Akpolat YT, Chien A, Cheng WK. MRI evaluation of the knee with non-ferromagnetic external fixators: cadaveric knee model. Eur J Orthop Surg Traumatol. 2015;25(5):933–9.CrossRefPubMed Elsissy P, Akpolat YT, Chien A, Cheng WK. MRI evaluation of the knee with non-ferromagnetic external fixators: cadaveric knee model. Eur J Orthop Surg Traumatol. 2015;25(5):933–9.CrossRefPubMed
12.
Zurück zum Zitat Ballard DH, Garrett JD, Simoncini AA, Barbeito S, Morandi MM. Safety and image quality of MR-conditional external fixators for 1.5 Tesla extremity MR. Emerg Radiol. 2021;28(3):581–8.CrossRefPubMedPubMedCentral Ballard DH, Garrett JD, Simoncini AA, Barbeito S, Morandi MM. Safety and image quality of MR-conditional external fixators for 1.5 Tesla extremity MR. Emerg Radiol. 2021;28(3):581–8.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Javidan P, Owen J, Cutuk A, Watson T, Kaar S. How do spanning external fixators on knee dislocation patients affect the use of MRI and knee stability? J Knee Surg. 2015;28(3):247–54.CrossRefPubMed Javidan P, Owen J, Cutuk A, Watson T, Kaar S. How do spanning external fixators on knee dislocation patients affect the use of MRI and knee stability? J Knee Surg. 2015;28(3):247–54.CrossRefPubMed
14.
Zurück zum Zitat Lo L, Jubouri S, Mulligan ME. MRI of traumatic knee dislocation: a study to evaluate safety and image quality for patients with knee-spanning stabilization devices. Curr Probl Diagn Radiol. 2022;51(3):317–22.CrossRefPubMed Lo L, Jubouri S, Mulligan ME. MRI of traumatic knee dislocation: a study to evaluate safety and image quality for patients with knee-spanning stabilization devices. Curr Probl Diagn Radiol. 2022;51(3):317–22.CrossRefPubMed
15.
Zurück zum Zitat Gillig JD, Goode RD, Campfield B, Crim JR, Crist BD. Safety and complications associated with MRI-conditional external fixators in patients with tibial plateau fractures: a case series. J Orthop Trauma. 2018;32(10):521–5.CrossRefPubMed Gillig JD, Goode RD, Campfield B, Crim JR, Crist BD. Safety and complications associated with MRI-conditional external fixators in patients with tibial plateau fractures: a case series. J Orthop Trauma. 2018;32(10):521–5.CrossRefPubMed
16.
Zurück zum Zitat Hayden BL, Theriault R, Bramlett K, Lucas R, McTague M, Bedi HS, et al. Magnetic resonance imaging of trauma patients treated with contemporary external fixation devices: a multicenter case series. J Orthop Trauma. 2017;31(11):e375–80.CrossRefPubMed Hayden BL, Theriault R, Bramlett K, Lucas R, McTague M, Bedi HS, et al. Magnetic resonance imaging of trauma patients treated with contemporary external fixation devices: a multicenter case series. J Orthop Trauma. 2017;31(11):e375–80.CrossRefPubMed
17.
Zurück zum Zitat Jungmann PM, Agten CA, Pfirrmann CW, Sutter R. Advances in MRI around metal. J Magn Reson Imaging. 2017;46(4):972–91.CrossRefPubMed Jungmann PM, Agten CA, Pfirrmann CW, Sutter R. Advances in MRI around metal. J Magn Reson Imaging. 2017;46(4):972–91.CrossRefPubMed
18.
Zurück zum Zitat Bernstein MA, Huston J, Ward HA. Imaging artifacts at 30T. J Magn Reson Imaging. 2006;24(4):735–46.CrossRefPubMed Bernstein MA, Huston J, Ward HA. Imaging artifacts at 30T. J Magn Reson Imaging. 2006;24(4):735–46.CrossRefPubMed
19.
Zurück zum Zitat Wang ZJ. Improving SNR of RF coils using composite coil elements. NMR Biomed. 2009;22(9):952–9.CrossRefPubMed Wang ZJ. Improving SNR of RF coils using composite coil elements. NMR Biomed. 2009;22(9):952–9.CrossRefPubMed
20.
Zurück zum Zitat Krätzig T, Mende KC, Mohme M, Kniep H, Dreimann M, Stangenberg M, et al. Carbon fiber-reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg Rev. 2021;44(4):2163–70.CrossRefPubMed Krätzig T, Mende KC, Mohme M, Kniep H, Dreimann M, Stangenberg M, et al. Carbon fiber-reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg Rev. 2021;44(4):2163–70.CrossRefPubMed
21.
Zurück zum Zitat Ringel F, Ryang Y, Kirschke JS, Müller BS, Wilkens JJ, Brodard J, et al. Radiolucent carbon fiber-reinforced pedicle screws for treatment of spinal tumors: advantages for radiation planning and follow-up imaging. World Neurosurg. 2017;105:294–301.CrossRefPubMed Ringel F, Ryang Y, Kirschke JS, Müller BS, Wilkens JJ, Brodard J, et al. Radiolucent carbon fiber-reinforced pedicle screws for treatment of spinal tumors: advantages for radiation planning and follow-up imaging. World Neurosurg. 2017;105:294–301.CrossRefPubMed
22.
Zurück zum Zitat Fleege C, Makowski M, Rauschmann M, Fraunhoffer KL, Fennema P, Arabmotlagh M, et al. Carbon fiber-reinforced pedicle screws reduce artifacts in magnetic resonance imaging of patients with lumbar spondylodesis. Sci Rep. 2020;10(1):16094–5.ADSCrossRefPubMedPubMedCentral Fleege C, Makowski M, Rauschmann M, Fraunhoffer KL, Fennema P, Arabmotlagh M, et al. Carbon fiber-reinforced pedicle screws reduce artifacts in magnetic resonance imaging of patients with lumbar spondylodesis. Sci Rep. 2020;10(1):16094–5.ADSCrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Harris CA, White LM. Metal artifact reduction in musculoskeletal magnetic resonance imaging. Orthop Clin North Am. 2006;37(3):349–59 vi.CrossRefPubMed Harris CA, White LM. Metal artifact reduction in musculoskeletal magnetic resonance imaging. Orthop Clin North Am. 2006;37(3):349–59 vi.CrossRefPubMed
24.
Zurück zum Zitat Kwok WE. Basic principles of and practical guide to clinical MRI radiofrequency coils. Radiographics. 2022;42(3):898–918.CrossRefPubMed Kwok WE. Basic principles of and practical guide to clinical MRI radiofrequency coils. Radiographics. 2022;42(3):898–918.CrossRefPubMed
25.
Zurück zum Zitat Farrelly C, Davarpanah A, Brennan SA, Sampson M, Eustace SJ. Imaging of soft tissues adjacent to orthopedic hardware: comparison of 3-T and 1.5-T MRI. AJR Am J Roentgenol. 2010;194(1):60.CrossRef Farrelly C, Davarpanah A, Brennan SA, Sampson M, Eustace SJ. Imaging of soft tissues adjacent to orthopedic hardware: comparison of 3-T and 1.5-T MRI. AJR Am J Roentgenol. 2010;194(1):60.CrossRef
26.
Metadaten
Titel
Magnetic resonance imaging quality in the context of a knee-spanning external fixator placed inside the MR bore: a literature review
verfasst von
Aaron J. Marcel
Joshua S. Green
Jack Porrino
Lee D. Katz
Michael J. Medvecky
Publikationsdatum
13.11.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 4/2024
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-023-04505-2

Weitere Artikel der Ausgabe 4/2024

Skeletal Radiology 4/2024 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.