Skip to main content

Open Access 18.05.2024 | Original Article

Novel Uses of the SwiftNinja Steerable Microcatheter for Pediatric Cardiovascular Interventions

verfasst von: Christopher Herron, Shabana Shahanavaz

Erschienen in: Pediatric Cardiology

Abstract

In the present era, the intricacy of procedures undertaken by a pediatric interventional cardiologist has increased, primarily attributed to dealing with smaller, younger patients with more complex anatomies. To adapt to these smaller and more complex patients, we must adapt our interventions and our equipment to perform these procedures. This article outlines various innovative applications of the SwiftNinja steerable microcatheter within the pediatric cardiac catheterization laboratory.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Cases within the pediatric cardiac catheterization lab are becoming increasingly nuanced with smaller patients, more complex anatomies and sicker patients. To successfully intervene in this patient population our equipment must be able to get us to areas that are difficult to access. The SwiftNinja steerable microcatheter (Merit Medical, South Jordan, UT, USA) is a 2.4Fr catheter that has an intraluminal diameter allowing up to a 0.018″ wire and has up to 180-degree directionality. While initially created for adult applications such as percutaneous coronary interventions, neurovascular aneurysms, acute ischemic strokes and peripheral interventions, this catheter is extremely versatile and has many applications in pediatric congenital heart disease patients [17]. We present a case based review of the many applications for this steerable microcatheter in the pediatric cardiac catheterization lab.

PDA Recanalization

A 13-day-old male with tricuspid atresia, normally related arteries with severely hypoplastic right ventricle had persistent desaturations with spontaneous closure of his patent ductus arteriosus (PDA). He was brought to the cardiac catheterization lab for attempted recanalization of his PDA. Initial angiography depicted absence of flow through a PDA except for in the small aortic ampulla (Fig. 1A, B). A rail was created using the SwiftNinja steerable microcatheter and a 0.014’ CTO wire through a 4Fr JR catheter. The SwiftNinja allowed us to have steep angulation within the aortic ampulla and direct the wire and traverse the course of the slightly tortuous duct in the direction of the presumed main pulmonary artery (Fig. 1C, D). A wire was then incrementally advanced from the aorta to the main pulmonary artery and into the right ventricle using the SwiftNinja to steer as required. The newly recanalized ductus was then stented using a drug eluding stent (DES) with appropriate retrograde flow into the branch pulmonary arteries (Fig. 1E, F). 5 months later he was able to undergo a successful Bidirectional Glenn palliation.

Pulmonary Valve Perforation

A 2-day-old male weighing 3.5 kg was born with membranous pulmonary atresia, ventricular septal defect and major aorto-pulmonary collateral vessels (MAPCAs). Native pulmonary arteries were present though severely hypoplastic and no PDA was present. Initial angiography revealed 3 large MAPCAs, with 2 of them connecting to the native pulmonary arteries. Initially attempts were made to obtain an appropriate catheter position in the right ventricular outflow tract (RVOT) to perform antegrade perforation but was unsuccessful given the horizontal position and the small size of the target main pulmonary artery. We then proceeded to place the SwiftNinja microcatheter through the left sided MAPCA retrograde into the native main pulmonary artery and one into the right ventricular outflow tract as a perforation target (Fig. 2A, B). A 0.014' CTO wire was advanced through the SwiftNinja microcatheter which helped achieve better alignment given the ability to steer. The atretic pulmonary valve was then perforated retrograde and retrograde RVOT stenting was performed using a DES coronary stent. Post intervention angiography showed an unobstructed RVOT with brisk flow into the native pulmonary arteries (Fig. 2C, D). The patient was then brought back to the cardiac catheterization lab for further balloon dilation of the RVOT stent 5 weeks later with interval growth of the native pulmonary arteries (Fig. 2E, F).

Mee Shunt Recanalization

A 2-month-old male born with complete atrioventricular septal defect, double outlet right ventricle with pulmonary atresia, confluent but severely hypoplastic native pulmonary arteries and MAPCAs underwent a Mee shunt at 1 month of age connecting the native pulmonary arteries to the ascending aorta. No flow was visualized a week post operatively, so the patient was brought to the cardiac catheterization lab for recanalization. Multiple catheter and wire combinations were attempted to gain access to the shunt. Ultimately, the SwiftNinja steerable microcatheter and a 0.014 wire through a 4Fr MPA 2 catheter gained access to the shunt (Fig. 3A, B). The native pulmonary arteries were severely hypoplastic post recanalization (Fig. 3C). The shunt was then stented with a DES coronary stent. The patient was brought back to the cardiac catheterization lab for further dilation of the Mee shunt and native pulmonary arteries. The SwiftNinja steerable microcatheter was again used to gain access to the stented Mee shunt due to the extreme angulation from the ascending aorta (Fig. 3D, E). The shunt and native pulmonary arteries were further balloon dilated with significant improvement to their caliber (Fig. 3F).

Pulmonary Flow Restrictors

A 3 week old, 31 week premature female with double outlet right ventricle, subaortic VSD, severe pulmonary stenosis and aortic stenosis along with a large AP window presented for bilateral pulmonary artery flow restrictors due to the patient’s weight of 1.7 kg. Through femoral venous access, a 0.018 wire was able to be placed in the right lower pulmonary artery with the help of the SwiftNinja steerable microcatheter (Fig. 4A, B). Given the acute angulation of the pulmonary arteries and the near pulmonary atresia the SwiftNinja was able to steer the wire into branch pulmonary arteries without the need of stiff guide catheter (Fig. 4C, D). Once the wire and microcatheter were placed distally, a JB1 catheter was able to track into the lower pulmonary artery for device deployment. Medtronic 7Q microvascular plugs (Medtronic, Minneapolis, MN, USA) were placed in both pulmonary arteries successfully (Fig. 4E, F).

Mechanical Thrombectomy

A 3-year-old previously healthy female presented with fatigue, lower extremity edema and was found to be extremely anemic with a hemoglobin of 3.7 g/dL due to a diagnosis of very early onset inflammatory bowel disease. A CT scan was performed revealing extensive, near occlusive thrombus from the infrahepatic inferior vena cava down to the bilateral popliteal veins (Fig. 5A, B). She was brought to the catheterization lab for mechanical thrombectomy using the Penumbra Indigo aspiration system (Penumbra Inc, Alameda, CA). Once past the common iliac vein, the SwiftNinja steerable microcatheter was able to navigate the significant thrombus burden and gain distal position. It was particularly useful in the smaller popliteal branches so that multiple branches could be accessed and thrombectomy performed. Post intervention angiography showed significant improvement from the common iliac vein down to the popliteal vein (Fig. 5C, D).

Premature PDA Device Retrieval

A 5-week-old female born prematurely at 27 weeks was found to have a large PDA with left heart dilation. She was brought to the catheterization lab for transcatheter PDA closure. Initially, a 5-2 Amplatzer Piccolo PDA occluder (Abbott, North Chicago, IL) was chosen for the large PDA. The device was deployed, and echocardiogram depicted trivial residual shunt with no left pulmonary artery stenosis or coarctation, so the device was released. The device embolized to the main pulmonary artery just after release. A 4Fr Flexor sheath was introduced into the main pulmonary artery through which a JB1, SwiftNinja steerable microcatheter and microsnare were introduced. Using the directionality of the SwiftNinja steerable microcatheter allowed us to place the snare on the Piccolo pin and retrieve the entire system back into the long sheath successfully (Fig. 6A, B). The ability to grab the pin specifically allows for an easier retrieval when removing the device through a long sheath versus grabbing the body of the device.

Discussion

The SwiftNinja steerable microcatheter has become our go to microcatheter due to its 180-degree directionality, ability to take a 0.018 wire and the overall ease of use. We have utilized this catheter for a multitude of congenital heart disease anatomies and in a variety of procedures.
Initial reports describe its use in adult patients for percutaneous coronary interventions, ischemic strokes, neurovascular aneurysms and peripheral interventions [14]. Hoffmann et al. described their use of the SwiftNinja microcatheter in peripheral vessel interventions and the significant reduction in time to target vessel cannulation and a reduction in radiation exposure [7]. Other unique applications have been described such as embolization of lymphatic vessel chylous ascites, anorectal variceal due to bleeding and a pulmonary artery pseudoaneurysm [810].
Pediatric congenital catheterizations are often challenging due to small spaces with tighter turns and the challenges are only augmented by having to use equipment “borrowed” from adult interventionalist which are not made to traverse the pediatric vasculature. Procedural complications in published reports are highest in the neonatal population with younger age and weight associated with higher adverse event rates [11, 12]. While cannulation of vessels in the adult population can be augmented with guide catheters and deflectable sheaths for support and directionality, this avenue is generally not possible in our neonatal population. The stiffness of the catheter can also prop open the tricuspid valve when used in the right heart, which in a neonate can cause significant hemodynamic compromise or rarely can cause vessel perforation with advancement. These reasons have led to the increased use of steerable microcatheters for directionality within vessels. The use of microcatheters likely reduces the duration of the procedure although we did not systematically evaluate the duration of the procedure. This is a very important aspect as duration of procedure was also found to be an independent predictor of outcomes. Catheter based RVOT perforations in neonates with pulmonary atresia and tetralogy of Fallot is considered one of the highest risk procedures especially due to the offset of the RVOT and the main pulmonary artery as well as the inability of catheters to angulate within the anatomy [1316]. The SwiftNinja steerable microcatheter can be used to guide the CTO wire or RF wire towards the MPA or in retrograde perforations towards the RVOT with more precision.
The recapture of an embolized device is often complicated by the inability to grab the “pin” of the device. Although the device can be snared along its body this can make it challenging to recapture within the sheath and might warrant upsizing the sheath [17, 18]. The pin often might be turned away from the path of approach making it more challenging to grab. The ability of the SwiftNinja steerable microcatheter to move beyond the device due to its small caliber and to achieve a tight curvature to grab the pin can certainly reduce the need for upsizing the sheath or using undue force in device retrieval.
The use of the SwiftNinja steerable microcatheter has been described in the pediatric population for splenic and renal artery embolization and in a pediatric patient with Fontan physiology requiring embolization of a portosystemic shunt [5, 6]. Its use in the pediatric population, however, is not limited to just embolization. As we have described above, its ability to cannulate very small tortuous vessels allows for a multitude of procedures to be performed and can even help rescue the interventionalist from device embolization. The SwiftNinja steerable microcatheter has become our go to microcatheter for a multitude of procedures performed in complex congenital heart disease and in small pediatric patients.

Conclusion

As the patients a pediatric interventional cardiologist is intervening upon become more complex and smaller, we must adapt our interventions and equipment to suit this population. We describe the use of the SwiftNinja steerable microcatheter in a variety of congenital heart disease anatomies and in a variety of interventional procedures.

Declarations

Conflict of interest

The authors declare that they do not have any conflict of interest.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

e.Med Pädiatrie

Kombi-Abonnement

Mit e.Med Pädiatrie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Pädiatrie, den Premium-Inhalten der pädiatrischen Fachzeitschriften, inklusive einer gedruckten Pädiatrie-Zeitschrift Ihrer Wahl.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Jetzt bestellen und 100 € sparen!

Literatur
1.
Zurück zum Zitat Harmon TS, Hulsberg PC, McFarland JR 3rd, Villescas VV, Matteo J (2019) Time is brain: the future for acute ischemic stroke management is the utilization of steerable microcatheters for reperfusion. Cureus. 11(1):e3842PubMedPubMedCentral Harmon TS, Hulsberg PC, McFarland JR 3rd, Villescas VV, Matteo J (2019) Time is brain: the future for acute ischemic stroke management is the utilization of steerable microcatheters for reperfusion. Cureus. 11(1):e3842PubMedPubMedCentral
3.
Zurück zum Zitat Kassimis G, Kontogiannis N, Raina T (2019) Steerable microcatheters for complex percutaneous coronary interventions in octogenarians: from Venture to Swift Ninja. J Geriatr Cardiol 16(1):54–59PubMedPubMedCentral Kassimis G, Kontogiannis N, Raina T (2019) Steerable microcatheters for complex percutaneous coronary interventions in octogenarians: from Venture to Swift Ninja. J Geriatr Cardiol 16(1):54–59PubMedPubMedCentral
4.
Zurück zum Zitat Soyama T, Yoshida D, Sakuhara Y, Morita R, Abo D, Kudo K (2017) The steerable microcatheter: a new device for selective catheterisation. Cardiovasc Intervent Radiol 40(6):947–952CrossRefPubMed Soyama T, Yoshida D, Sakuhara Y, Morita R, Abo D, Kudo K (2017) The steerable microcatheter: a new device for selective catheterisation. Cardiovasc Intervent Radiol 40(6):947–952CrossRefPubMed
5.
Zurück zum Zitat Harmon TS, Kee-Sampson J, Hester TS, Bashir S, Matteo J (2019) Pediatric traumas and paradigm shifts: the necessary adaption of the steerable microcatheter in pediatric interventional radiology. Cureus. 11(2):e4125PubMedPubMedCentral Harmon TS, Kee-Sampson J, Hester TS, Bashir S, Matteo J (2019) Pediatric traumas and paradigm shifts: the necessary adaption of the steerable microcatheter in pediatric interventional radiology. Cureus. 11(2):e4125PubMedPubMedCentral
7.
Zurück zum Zitat Hoffmann JC, Minkin J, Primiano N, Yun J, Eweka A (2019) Use of a steerable microcatheter during superselective angiography: impact on radiation exposure and procedural efficiency. CVIR Endovasc. 2(1):35CrossRefPubMedPubMedCentral Hoffmann JC, Minkin J, Primiano N, Yun J, Eweka A (2019) Use of a steerable microcatheter during superselective angiography: impact on radiation exposure and procedural efficiency. CVIR Endovasc. 2(1):35CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Hamaguchi S, Michigami Y, Inoue M, Tsukamoto K, Wada S, Ogawa Y (2022) Successful treatment of chylous ascites by superselective embolization of the inflowing lymphatic vessels using a steerable microcatheter: a case study. Radiol Case Rep. 17(9):3205–3208CrossRefPubMedPubMedCentral Hamaguchi S, Michigami Y, Inoue M, Tsukamoto K, Wada S, Ogawa Y (2022) Successful treatment of chylous ascites by superselective embolization of the inflowing lymphatic vessels using a steerable microcatheter: a case study. Radiol Case Rep. 17(9):3205–3208CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Chatani S, Seki K, Sonoda A et al (2022) Bleeding anorectal varices treated by a direct puncture approach through the greater sciatic foramen: the utility of a steerable microcatheter for reverse catheterization. Radiol Case Rep. 17(4):1104–1109CrossRefPubMedPubMedCentral Chatani S, Seki K, Sonoda A et al (2022) Bleeding anorectal varices treated by a direct puncture approach through the greater sciatic foramen: the utility of a steerable microcatheter for reverse catheterization. Radiol Case Rep. 17(4):1104–1109CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Umakoshi N, Arai Y, Sone M, Sugawara S (2019) Compact coil packing using a steerable microcatheter for a giant wide-necked pulmonary artery pseudoaneurysm. Interact Cardiovasc Thorac Surg 28(5):826–827CrossRefPubMed Umakoshi N, Arai Y, Sone M, Sugawara S (2019) Compact coil packing using a steerable microcatheter for a giant wide-necked pulmonary artery pseudoaneurysm. Interact Cardiovasc Thorac Surg 28(5):826–827CrossRefPubMed
11.
Zurück zum Zitat Lin CH, Hegde S, Marshall AC et al (2014) Incidence and management of life-threatening adverse events during cardiac catheterization for congenital heart disease. Pediatr Cardiol 35:140–148CrossRefPubMed Lin CH, Hegde S, Marshall AC et al (2014) Incidence and management of life-threatening adverse events during cardiac catheterization for congenital heart disease. Pediatr Cardiol 35:140–148CrossRefPubMed
12.
Zurück zum Zitat Quinn BP, Yeh M, Gauvreau K, Ali F, Balzer D, Barry O, Batlivala S, Berman D, Foerster S, Goldstein B, Hainstock M, Holzer R, Janssen D, O’Byrne ML, Shirley L, Trucco S, Whiteside W, Bergersen L (2022) Procedural risk in congenital cardiac catheterization (PREDIC3T). J Am Heart Assoc 11(1):e022832CrossRefPubMed Quinn BP, Yeh M, Gauvreau K, Ali F, Balzer D, Barry O, Batlivala S, Berman D, Foerster S, Goldstein B, Hainstock M, Holzer R, Janssen D, O’Byrne ML, Shirley L, Trucco S, Whiteside W, Bergersen L (2022) Procedural risk in congenital cardiac catheterization (PREDIC3T). J Am Heart Assoc 11(1):e022832CrossRefPubMed
13.
Zurück zum Zitat Agnoletti G, Piechaud JF, Bonhoeffer P et al (2003) Perforation of the atretic pulmonary valve. Long-term follow-up. J Am Coll Cardiol 41(8):1399–1403CrossRefPubMed Agnoletti G, Piechaud JF, Bonhoeffer P et al (2003) Perforation of the atretic pulmonary valve. Long-term follow-up. J Am Coll Cardiol 41(8):1399–1403CrossRefPubMed
14.
Zurück zum Zitat Alwi M, Geetha K, Bilkis AA et al (2000) Pulmonary atresia with intact ventricular septum percutaneous radiofrequency-assisted valvotomy and balloon dilation versus surgical valvotomy and Blalock Taussig shunt. J Am Coll Cardiol 35(2):468–476CrossRefPubMed Alwi M, Geetha K, Bilkis AA et al (2000) Pulmonary atresia with intact ventricular septum percutaneous radiofrequency-assisted valvotomy and balloon dilation versus surgical valvotomy and Blalock Taussig shunt. J Am Coll Cardiol 35(2):468–476CrossRefPubMed
15.
Zurück zum Zitat Humpl T, Söderberg B, McCrindle BW et al (2003) Percutaneous balloon valvotomy in pulmonary atresia with intact ventricular septum: impact on patient care. Circulation 108(7):826–832CrossRefPubMed Humpl T, Söderberg B, McCrindle BW et al (2003) Percutaneous balloon valvotomy in pulmonary atresia with intact ventricular septum: impact on patient care. Circulation 108(7):826–832CrossRefPubMed
16.
Zurück zum Zitat Holzer R, Batlivala SP, Boe B et al (2023) The need for surgery after vascular or cardiac trauma, or technical adverse events in the congenital cardiac catheterization laboratory. Pediatr Cardiol 44(4):795–805CrossRefPubMed Holzer R, Batlivala SP, Boe B et al (2023) The need for surgery after vascular or cardiac trauma, or technical adverse events in the congenital cardiac catheterization laboratory. Pediatr Cardiol 44(4):795–805CrossRefPubMed
17.
Zurück zum Zitat Sathanandam S, Gutfinger D, Morray B et al (2021) Consensus guidelines for the prevention and management of periprocedural complications of transcatheter patent ductus arteriosus closure with the amplatzer piccolo occluder in extremely low birth weight infants. Pediatr Cardiol 42(6):1258–1274CrossRefPubMedPubMedCentral Sathanandam S, Gutfinger D, Morray B et al (2021) Consensus guidelines for the prevention and management of periprocedural complications of transcatheter patent ductus arteriosus closure with the amplatzer piccolo occluder in extremely low birth weight infants. Pediatr Cardiol 42(6):1258–1274CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Garg R, Zahn E, Sathanandam S, Johnson JN (2021) Transcatheter patent ductus arteriosus closure in extremely premature infants. Prog Pediatr Cardiol 61:101366CrossRef Garg R, Zahn E, Sathanandam S, Johnson JN (2021) Transcatheter patent ductus arteriosus closure in extremely premature infants. Prog Pediatr Cardiol 61:101366CrossRef
Metadaten
Titel
Novel Uses of the SwiftNinja Steerable Microcatheter for Pediatric Cardiovascular Interventions
verfasst von
Christopher Herron
Shabana Shahanavaz
Publikationsdatum
18.05.2024
Verlag
Springer US
Erschienen in
Pediatric Cardiology
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-024-03516-7

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.