Skip to main content
Erschienen in: Pediatric Cardiology 4/2024

27.02.2024 | Research

Prenatal Predictors for Pulmonary Balloon Valvuloplasty in the Newborn

verfasst von: Jennifer A. Johnson, Timothy Canavan, Tarek Alsaied, Lisa Howley, Hayley S. Hancock, Divya Suthar, Elisa Marcuccio, Taylor M. Trussell, Bettina Cuneo

Erschienen in: Pediatric Cardiology | Ausgabe 4/2024

Einloggen, um Zugang zu erhalten

Abstract

Pulmonary balloon valvuloplasty (PBV) is the treatment of choice for subjects with isolated pulmonary valve stenosis (IPS). The purpose of this study was to define fetal echocardiographic features associated with an inpatient PBV prior to newborn hospital discharge and characterize resource utilization of IPS fetuses among participating centers. Six center, retrospective case series of singleton fetuses identified between 2010 and 2020 with IPS. Third-trimester echocardiogram data was compared with postnatal data, included pulmonary valve Doppler velocities, pulmonary valve insufficiency and ductus arteriosus flow direction. Comparison between subjects who underwent inpatient PBV during their newborn hospital admission versus those infants referred for outpatient PBV after initial hospital discharge. We analyzed data by logistic regression, student t test and Chi-Square testing with a p value of ≤ 0.05 considered statistically significant. Forty-nine IPS fetuses were identified. Thirty-eight (78%) underwent inpatient PBV at 5 (range 1–58) days and 11 (22%) underwent outpatient PBV at 51.8 (11–174) days. Newborns requiring an inpatient PBV were more likely to have one or more characteristics on 3rd-trimester fetal echocardiogram: left to right or bidirectional ductus arteriosus flow (61% vs 0%), and/or a peak pulmonary valve velocity > 3.0 m/s (odds ratio 16.9, 95% confidence interval 3.02–94.17) with a sensitivity of 90.4% and specificity of 97.7%. Ductus arteriosus flow direction and pulmonary valve peak velocity in the 3rd trimester can successfully predict the need for newborn inpatient PBV. We speculate these findings may be useful in choosing delivery site for the pregnancy complicated by fetal IPS.
Literatur
8.
Zurück zum Zitat Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG (2009) Research electronic data capture (REDCap)—a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform 42(2):377–381CrossRefPubMed Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG (2009) Research electronic data capture (REDCap)—a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform 42(2):377–381CrossRefPubMed
12.
Zurück zum Zitat Gardiner HM, Belmar C, Tulzer G, Barlow A, Pasquini L, Carvalho JS, Daubeney PE, Rigby ML, Gordon F, Kulinskaya E, Franklin RC (2008) Morphologic and functional predictors of eventual circulation in the fetus with pulmonary atresia or critical pulmonary stenosis with intact septum. J Am Coll Cardiol 51(13):1299–1308. https://doi.org/10.1016/j.jacc.2007.08.073CrossRefPubMed Gardiner HM, Belmar C, Tulzer G, Barlow A, Pasquini L, Carvalho JS, Daubeney PE, Rigby ML, Gordon F, Kulinskaya E, Franklin RC (2008) Morphologic and functional predictors of eventual circulation in the fetus with pulmonary atresia or critical pulmonary stenosis with intact septum. J Am Coll Cardiol 51(13):1299–1308. https://​doi.​org/​10.​1016/​j.​jacc.​2007.​08.​073CrossRefPubMed
13.
14.
Zurück zum Zitat Lowenthal A, Lemley B, Kipps AK, Brook MM, Moon-Grady AJ (2014) Prenatal tricuspid valve size as a predictor of postnatal outcome in patients with severe pulmonary stenosis or pulmonary atresia with intact ventricular septum. Fetal Diagn Ther 35(2):101–107. https://doi.org/10.1159/000357429CrossRefPubMed Lowenthal A, Lemley B, Kipps AK, Brook MM, Moon-Grady AJ (2014) Prenatal tricuspid valve size as a predictor of postnatal outcome in patients with severe pulmonary stenosis or pulmonary atresia with intact ventricular septum. Fetal Diagn Ther 35(2):101–107. https://​doi.​org/​10.​1159/​000357429CrossRefPubMed
16.
Zurück zum Zitat Rudolph A (2009) Congenital disease of the heart: clinical-physiological considerations. Wiley-Blackwell, OxfordCrossRef Rudolph A (2009) Congenital disease of the heart: clinical-physiological considerations. Wiley-Blackwell, OxfordCrossRef
Metadaten
Titel
Prenatal Predictors for Pulmonary Balloon Valvuloplasty in the Newborn
verfasst von
Jennifer A. Johnson
Timothy Canavan
Tarek Alsaied
Lisa Howley
Hayley S. Hancock
Divya Suthar
Elisa Marcuccio
Taylor M. Trussell
Bettina Cuneo
Publikationsdatum
27.02.2024
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 4/2024
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-024-03430-y

Weitere Artikel der Ausgabe 4/2024

Pediatric Cardiology 4/2024 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.