Introduction

In in-vitro dental radiographic research, simulation of soft tissue is required to replicate the clinical condition as close as possible. This study aimed to find out which soft tissue simulation material have been studied to use in dentomaxillofacial radiology and showed similarity in radiodensity to the soft tissues of the maxillofacial region.

Methods

In this scoping review, Web of Science, Embase, Scopus, Google scholar and PubMed databases were searched on April 9, 2023, considering the following PICOS: Population: soft tissue simulants, Intervention: X-ray-based imaging, Comparison: —, Outcome: properties of the soft tissue simulants, Study design: in-vitro studies. Screening, study selection, and data extraction were performed by two independent researchers. A third team member was consulted in the case of disagreement. Quality assessment of the included studies was made using Quality Assessment Tool For In-Vitro Studies (QUIN Tool).

Results

Of the initial 1172 articles retrieved in the database search, 13 studies were included in the review. Seven studies had a low risk of bias. In 8 studies, computed tomography (CT) or cone beam computed tomography (CBCT), in 4 studies intraoral radiography, and in 2 studies panoramic radiography was used (one study has used CT/CBCT and panoramic radiography). The studies varied in the radiographic modality, acquisition parameters, selected outcomes, and gold standard. In the majority of the studies (n = 10, 77%), acrylic resin derivatives were used in the soft tissue simulant formula alone or as a major component. Wax was used in the simulant material in 8 studies (62%). In addition, in 3 studies (23%) ice/water was used as the main simulant.

Conclusion

Ballistic gelatin, expanded 2-cm thick polystyrene with or without 1-cm utility wax, and 0.5 cm of acrylic resin were shown to have a radiographic density similar to soft tissue in standardized studies employing CBCT scanning. For intraoral radiographs, using self-polymerizing acrylic resin, utility wax, and wood, as well as a polymethylmethacrylate box filled with water in thicknesses ranging from 4 to 45 mm, provides suitable radiographic contrast. However, for 4 and 8 mm of wax and 4 mm of water, the radiographic contrast is not appropriate. In addition, 13–17 mm wax and 14.5 mm acrylic resin showed acceptable soft tissue densities in intraoral radiography. Further studies using different imaging modalities with standardized conditions and objective metrics are required to confirm the most appropriate soft tissue simulant material for in-vitro dental radiographic research.
Literatur
1.
Zurück zum Zitat Saeidnia S, Manayi A, Abdollahi M. From in vitro experiments to in vivo and clinical studies; pros and cons. Curr Drug Discov Technol. 2015;12(4):218–24.CrossRefPubMed Saeidnia S, Manayi A, Abdollahi M. From in vitro experiments to in vivo and clinical studies; pros and cons. Curr Drug Discov Technol. 2015;12(4):218–24.CrossRefPubMed
2.
Zurück zum Zitat Abdinian M, Moshkforoush S, Hemati H, Soltani P, Moshkforoushan M, Spagnuolo G. Comparison of cone beam computed tomography and digital radiography in detecting separated endodontic files and strip perforation. Appl Sci. 2020;10(23):8726.CrossRef Abdinian M, Moshkforoush S, Hemati H, Soltani P, Moshkforoushan M, Spagnuolo G. Comparison of cone beam computed tomography and digital radiography in detecting separated endodontic files and strip perforation. Appl Sci. 2020;10(23):8726.CrossRef
3.
Zurück zum Zitat Miri S, Mehralizadeh S, Sadri D, Motamedi MRK, Soltani P. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries. Imag Sci Dentist. 2015;45(3):141–5.CrossRef Miri S, Mehralizadeh S, Sadri D, Motamedi MRK, Soltani P. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries. Imag Sci Dentist. 2015;45(3):141–5.CrossRef
4.
Zurück zum Zitat Sirin Y, Yildirimturk S, Horasan S, Guven K. Diagnostic potential of panoramic radiography and CBCT in detecting implant-related ex vivo injuries of the inferior alveolar canal border. J Oral Implantol. 2020;46(3):206–13.CrossRefPubMed Sirin Y, Yildirimturk S, Horasan S, Guven K. Diagnostic potential of panoramic radiography and CBCT in detecting implant-related ex vivo injuries of the inferior alveolar canal border. J Oral Implantol. 2020;46(3):206–13.CrossRefPubMed
5.
Zurück zum Zitat Molteni R. Prospects and challenges of rendering tissue density in Hounsfield units for cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116(1):105–19.CrossRefPubMed Molteni R. Prospects and challenges of rendering tissue density in Hounsfield units for cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116(1):105–19.CrossRefPubMed
6.
Zurück zum Zitat Souza PH, da Costa NP, Veeck EB. Influence of soft tissues on mandibular gray scale levels. Braz Oral Res. 2004;18(1):40–4.CrossRefPubMed Souza PH, da Costa NP, Veeck EB. Influence of soft tissues on mandibular gray scale levels. Braz Oral Res. 2004;18(1):40–4.CrossRefPubMed
7.
Zurück zum Zitat Blake GM, McKeeney DB, Chhaya SC, Ryan PJ, Fogelman I. Dual energy x-ray absorptiometry: the effects of beam hardening on bone density measurements. Med Phys. 1992;19(2):459–65.CrossRefPubMed Blake GM, McKeeney DB, Chhaya SC, Ryan PJ, Fogelman I. Dual energy x-ray absorptiometry: the effects of beam hardening on bone density measurements. Med Phys. 1992;19(2):459–65.CrossRefPubMed
8.
Zurück zum Zitat Borg E, Källqvist A, Gröndahl K, Gröndahl HG. Film and digital radiography for detection of simulated root resorption cavities. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;86(1):110–4.CrossRefPubMed Borg E, Källqvist A, Gröndahl K, Gröndahl HG. Film and digital radiography for detection of simulated root resorption cavities. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;86(1):110–4.CrossRefPubMed
9.
Zurück zum Zitat Caldas Mde P, Ramos-Perez FM, de Almeida SM, Haiter-Neto F. Comparative evaluation among different materials to replace soft tissue in oral radiology studies. J Appl Oral Sci. 2010;18(3):264–7.CrossRefPubMed Caldas Mde P, Ramos-Perez FM, de Almeida SM, Haiter-Neto F. Comparative evaluation among different materials to replace soft tissue in oral radiology studies. J Appl Oral Sci. 2010;18(3):264–7.CrossRefPubMed
10.
Zurück zum Zitat Cook JE, Cunningham JL. The assessment of fracture healing using dual x-ray absorptiometry: a feasibility study using phantoms. Phys Med Biol. 1995;40(1):119–36.CrossRefPubMed Cook JE, Cunningham JL. The assessment of fracture healing using dual x-ray absorptiometry: a feasibility study using phantoms. Phys Med Biol. 1995;40(1):119–36.CrossRefPubMed
11.
Zurück zum Zitat Hildebolt CF, Rupich RC, Vannier MW, Zerbolio DJ, Shrout MK, Cohen S, et al. Inter-relationships between bone mineral content measures. Dual energy radiography (DER) and bitewing radiographs (BWX). J Clin Periodontol. 1993;20(10):739–45.CrossRefPubMed Hildebolt CF, Rupich RC, Vannier MW, Zerbolio DJ, Shrout MK, Cohen S, et al. Inter-relationships between bone mineral content measures. Dual energy radiography (DER) and bitewing radiographs (BWX). J Clin Periodontol. 1993;20(10):739–45.CrossRefPubMed
12.
Zurück zum Zitat Richards AG, Webber RL. Constructing phantom heads for radiation research. Oral Surg Oral Med Oral Pathol. 1963;16:683–90.CrossRefPubMed Richards AG, Webber RL. Constructing phantom heads for radiation research. Oral Surg Oral Med Oral Pathol. 1963;16:683–90.CrossRefPubMed
13.
Zurück zum Zitat Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71.CrossRefPubMedPubMedCentral Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Ariji Y, Ariji E, Araki K, Kanda S. CT values of dental materials and preparation of phantoms with CT values equivalent to those of some human soft tissues. Radiat Prot Dosimetry. 1993;49(1–3):129–31.CrossRef Ariji Y, Ariji E, Araki K, Kanda S. CT values of dental materials and preparation of phantoms with CT values equivalent to those of some human soft tissues. Radiat Prot Dosimetry. 1993;49(1–3):129–31.CrossRef
16.
Zurück zum Zitat Oenning AC, Salmon B, Vasconcelos KdF, Pinheiro Nicolielo LF, Lambrichts I, Sanderink G, et al. DIMITRA paediatric skull phantoms: development of age-specific paediatric models for dentomaxillofacial radiology research. Dentomaxillofac Radiol. 2018;47(2):20170285.CrossRefPubMedPubMedCentral Oenning AC, Salmon B, Vasconcelos KdF, Pinheiro Nicolielo LF, Lambrichts I, Sanderink G, et al. DIMITRA paediatric skull phantoms: development of age-specific paediatric models for dentomaxillofacial radiology research. Dentomaxillofac Radiol. 2018;47(2):20170285.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Lopes PA, Santaella GM, Lima CAS, Vasconcelos KdF, Groppo FC. Evaluation of soft tissues simulant materials in cone beam computed tomography. Dentomaxillofac Radiol. 2019;48(1):20180072.CrossRefPubMed Lopes PA, Santaella GM, Lima CAS, Vasconcelos KdF, Groppo FC. Evaluation of soft tissues simulant materials in cone beam computed tomography. Dentomaxillofac Radiol. 2019;48(1):20180072.CrossRefPubMed
18.
Zurück zum Zitat Santaella GM, Visconti MAPG, Devito KL, Groppo FC, Haiter-Neto F, Asprino L. Evaluation of different soft tissue–simulating materials in pixel intensity values in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127(4):e102–7.CrossRefPubMed Santaella GM, Visconti MAPG, Devito KL, Groppo FC, Haiter-Neto F, Asprino L. Evaluation of different soft tissue–simulating materials in pixel intensity values in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127(4):e102–7.CrossRefPubMed
19.
Zurück zum Zitat Grehn M, Stille M, Ziemann C, Cremers F, Rades D, Buzug TM. A new phantom for individual verification of the dose distribution in precision radiotherapy for head-and-neck cancer. Anticancer Res. 2019;39(12):6931–8.CrossRefPubMed Grehn M, Stille M, Ziemann C, Cremers F, Rades D, Buzug TM. A new phantom for individual verification of the dose distribution in precision radiotherapy for head-and-neck cancer. Anticancer Res. 2019;39(12):6931–8.CrossRefPubMed
20.
Zurück zum Zitat Lee DI, Yang Z, Kim JH, eds. A 3D printing-based realistic anthropomorphic dental phantom and its imaging evaluation. In: Medical Imaging 2019: Imaging Informatics for Healthcare, Research, and Applications; 2019: SPIE Lee DI, Yang Z, Kim JH, eds. A 3D printing-based realistic anthropomorphic dental phantom and its imaging evaluation. In: Medical Imaging 2019: Imaging Informatics for Healthcare, Research, and Applications; 2019: SPIE
21.
Zurück zum Zitat Nascimento EHL, Fontenele RC, Lopes PA, Santaella GM, Vasconcelos KF, de Freitas DQ, et al. Development of a model of soft tissue simulation using ballistic gelatin for CBCT acquisitions related to dentomaxillofacial radiology research. Dentomaxillofac Radiol. 2021;50(3):20200191.CrossRefPubMed Nascimento EHL, Fontenele RC, Lopes PA, Santaella GM, Vasconcelos KF, de Freitas DQ, et al. Development of a model of soft tissue simulation using ballistic gelatin for CBCT acquisitions related to dentomaxillofacial radiology research. Dentomaxillofac Radiol. 2021;50(3):20200191.CrossRefPubMed
22.
Zurück zum Zitat Badiuk SR, Sasaki DK, Rickey DW. An anthropomorphic maxillofacial phantom using 3-dimensional printing, polyurethane rubber and epoxy resin for dental imaging and dosimetry. Dentomaxillofac Radiol. 2022;51(1):20200323.CrossRefPubMedPubMedCentral Badiuk SR, Sasaki DK, Rickey DW. An anthropomorphic maxillofacial phantom using 3-dimensional printing, polyurethane rubber and epoxy resin for dental imaging and dosimetry. Dentomaxillofac Radiol. 2022;51(1):20200323.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Brand JW, Kuba RK, Braunreiter TC. An improved head-and-neck phantom for radiation dosimetry. Oral Surg Oral Med Oral Pathol. 1989;67(3):338–46.CrossRefPubMed Brand JW, Kuba RK, Braunreiter TC. An improved head-and-neck phantom for radiation dosimetry. Oral Surg Oral Med Oral Pathol. 1989;67(3):338–46.CrossRefPubMed
24.
Zurück zum Zitat Schropp L, Alyass NS, Wenzel A, Stavropoulos A. Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies. Dentomaxillofac Radiol. 2012;41(8):686–90.CrossRefPubMedPubMedCentral Schropp L, Alyass NS, Wenzel A, Stavropoulos A. Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies. Dentomaxillofac Radiol. 2012;41(8):686–90.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat De Molon R, Batitucci R, Spin-Neto R, Paquier G, Sakakura C, Tosoni GM, et al. Comparison of changes in dental and bone radiographic densities in the presence of different soft-tissue simulators using pixel intensity and digital subtraction analyses. Dentomaxillofac Radiol. 2013;42(9):20130235.CrossRefPubMedPubMedCentral De Molon R, Batitucci R, Spin-Neto R, Paquier G, Sakakura C, Tosoni GM, et al. Comparison of changes in dental and bone radiographic densities in the presence of different soft-tissue simulators using pixel intensity and digital subtraction analyses. Dentomaxillofac Radiol. 2013;42(9):20130235.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Shin JM, Lee C, Kim JE, Huh KH, Yi WJ, Heo MS, et al. Contrast reference values in panoramic radiographic images using an arch-form phantom stand. Imaging Sci Dent. 2016;46(3):203–10.CrossRefPubMedPubMedCentral Shin JM, Lee C, Kim JE, Huh KH, Yi WJ, Heo MS, et al. Contrast reference values in panoramic radiographic images using an arch-form phantom stand. Imaging Sci Dent. 2016;46(3):203–10.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Payne T, Mitchell S, Bibb R, Waters M. The evaluation of new multi-material human soft tissue simulants for sports impact surrogates. J Mech Behav Biomed Mater. 2015;41:336–56.CrossRefPubMed Payne T, Mitchell S, Bibb R, Waters M. The evaluation of new multi-material human soft tissue simulants for sports impact surrogates. J Mech Behav Biomed Mater. 2015;41:336–56.CrossRefPubMed
28.
Zurück zum Zitat Cha BK, Jeon S, Seo C-W, Back J, Choi S, Lee C, et al. Optimization of X-ray image acquisition and reconstruction for a C-arm CBCT system with a flat-panel detector. Nucl Instrum Methods Phys Res, Sect A. 2019;924:343–9.ADSCrossRef Cha BK, Jeon S, Seo C-W, Back J, Choi S, Lee C, et al. Optimization of X-ray image acquisition and reconstruction for a C-arm CBCT system with a flat-panel detector. Nucl Instrum Methods Phys Res, Sect A. 2019;924:343–9.ADSCrossRef
29.
Zurück zum Zitat Wu P, Sisniega A, Stayman J, Zbijewski W, Foos D, Wang X et al., eds. Clinical study of soft-tissue contrast resolution in cone-beam CT of the head using multi-resolution PWLS with multi-motion correction and an electronic noise model. In: 15th international meeting on fully three-dimensional image reconstruction in radiology and nuclear medicine; 2019: SPIE Wu P, Sisniega A, Stayman J, Zbijewski W, Foos D, Wang X et al., eds. Clinical study of soft-tissue contrast resolution in cone-beam CT of the head using multi-resolution PWLS with multi-motion correction and an electronic noise model. In: 15th international meeting on fully three-dimensional image reconstruction in radiology and nuclear medicine; 2019: SPIE
30.
Zurück zum Zitat Santaella GM, Visconti M, Devito KL, Groppo FC, Haiter-Neto F, Asprino L. Evaluation of different soft tissue-simulating materials in pixel intensity values in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127(4):e102–7.CrossRefPubMed Santaella GM, Visconti M, Devito KL, Groppo FC, Haiter-Neto F, Asprino L. Evaluation of different soft tissue-simulating materials in pixel intensity values in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127(4):e102–7.CrossRefPubMed
31.
Zurück zum Zitat Oenning AC, Salmon B, Vasconcelos KF, Pinheiro Nicolielo LF, Lambrichts I, Sanderink G, et al. DIMITRA paediatric skull phantoms: development of age-specific paediatric models for dentomaxillofacial radiology research. Dentomaxillofac Radiol. 2018;47(3):20170285.CrossRefPubMedPubMedCentral Oenning AC, Salmon B, Vasconcelos KF, Pinheiro Nicolielo LF, Lambrichts I, Sanderink G, et al. DIMITRA paediatric skull phantoms: development of age-specific paediatric models for dentomaxillofacial radiology research. Dentomaxillofac Radiol. 2018;47(3):20170285.CrossRefPubMedPubMedCentral
Metadaten
Titel
Soft tissue simulant materials in X-ray-based imaging in dentomaxillofacial radiology: a scoping review
verfasst von
Parisa Soltani
Hugh Devlin
Ulkem Aydin
Kioumars Tavakoli Tafti
Kimia Baghaei
Publikationsdatum
22.12.2023
Verlag
Springer Nature Singapore
Erschienen in
Oral Radiology / Ausgabe 2/2024
Print ISSN: 0911-6028
Elektronische ISSN: 1613-9674
DOI
https://doi.org/10.1007/s11282-023-00721-7

Weitere Artikel der Ausgabe 2/2024

Oral Radiology 2/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.