Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2024

18.08.2023

Substrate and arrhythmia characterization using the multi-electrode Optrell mapping catheter for ventricular arrhythmia ablation—a single-center experience

verfasst von: Jian Liang Tan, Gustavo S. Guandalini, Matthew C. Hyman, Jeffrey Arkles, Pasquale Santangeli, Robert D. Schaller, Fermin Garcia, Gregory Supple, David S. Frankel, Saman Nazarian, David Lin, David Callans, Francis E. Marchlinski, Timothy M. Markman

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2024

Einloggen, um Zugang zu erhalten

Abstract

Background

The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported.

Objectives

We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs.

Methods

We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC.

Results

A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471–17,024] collected in the endocardium and 12,830 points [IQR 2319–30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534–3582] collected in the endocardium.

Conclusions

This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.
Literatur
1.
Zurück zum Zitat Tzou WS, Frankel DS, Hegeman T, et al. Core isolation of critical arrhythmia elements for treatment of multiple scar-based ventricular tachycardias. Circ Arrhythm Electrophysiol. 2015;8:353–61.CrossRefPubMed Tzou WS, Frankel DS, Hegeman T, et al. Core isolation of critical arrhythmia elements for treatment of multiple scar-based ventricular tachycardias. Circ Arrhythm Electrophysiol. 2015;8:353–61.CrossRefPubMed
2.
Zurück zum Zitat de Chillou C, Groben L, Magnin-Poull I, et al. Localizing the critical isthmus of postinfarct ventricular tachycardia: the value of pace-mapping during sinus rhythm. Heart Rhythm. 2014;11:175–81.CrossRefPubMed de Chillou C, Groben L, Magnin-Poull I, et al. Localizing the critical isthmus of postinfarct ventricular tachycardia: the value of pace-mapping during sinus rhythm. Heart Rhythm. 2014;11:175–81.CrossRefPubMed
3.
Zurück zum Zitat Parreira L, Marinheiro R, Carmo P, et al. Isolated diastolic potentials as predictors of success in ablation of right ventricular outflow tract idiopathic premature ventricular contractions. PLoS One. 2019;14: e0211232.CrossRefPubMedPubMedCentral Parreira L, Marinheiro R, Carmo P, et al. Isolated diastolic potentials as predictors of success in ablation of right ventricular outflow tract idiopathic premature ventricular contractions. PLoS One. 2019;14: e0211232.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Aziz Z, Shatz D, Raiman M, et al. Targeted ablation of ventricular tachycardia guided by wavefront discontinuities during sinus rhythm: a new functional substrate mapping strategy. Circulation. 2019;140:1383–97.CrossRefPubMed Aziz Z, Shatz D, Raiman M, et al. Targeted ablation of ventricular tachycardia guided by wavefront discontinuities during sinus rhythm: a new functional substrate mapping strategy. Circulation. 2019;140:1383–97.CrossRefPubMed
5.
Zurück zum Zitat Matto F, Venugopal D, Bhave PD, Rhodes TE, Mazur A. Utility of high resolution mapping to guide ablation of ventricular arrhythmias from the aortic sinuses of Valsalva. J Interv Card Electrophysiol. 2023;66:51–9.CrossRefPubMed Matto F, Venugopal D, Bhave PD, Rhodes TE, Mazur A. Utility of high resolution mapping to guide ablation of ventricular arrhythmias from the aortic sinuses of Valsalva. J Interv Card Electrophysiol. 2023;66:51–9.CrossRefPubMed
6.
Zurück zum Zitat Yavin HD, Bubar ZP, Higuchi K, Sroubek J, Yarnitsky J, Anter E. Propagation vectors facilitate differentiation between conduction block, slow conduction, and wavefront collision. Circ Arrhythm Electrophysiol. 2021;14: e010081.CrossRefPubMed Yavin HD, Bubar ZP, Higuchi K, Sroubek J, Yarnitsky J, Anter E. Propagation vectors facilitate differentiation between conduction block, slow conduction, and wavefront collision. Circ Arrhythm Electrophysiol. 2021;14: e010081.CrossRefPubMed
7.
Zurück zum Zitat Younis A, Yarnitsky J, Rodriguez H, Bubar ZP, Zilberman I, Anter E. Multipolar electrograms: a novel algorithm for accurate annotation of near-field potentials in scar. Heart Rhythm. 2022;19:S511.CrossRef Younis A, Yarnitsky J, Rodriguez H, Bubar ZP, Zilberman I, Anter E. Multipolar electrograms: a novel algorithm for accurate annotation of near-field potentials in scar. Heart Rhythm. 2022;19:S511.CrossRef
8.
Zurück zum Zitat Marchlinski FE, Callans DJ, Gottlieb CD, Zado E. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation. 2000;101:1288–96.CrossRefPubMed Marchlinski FE, Callans DJ, Gottlieb CD, Zado E. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation. 2000;101:1288–96.CrossRefPubMed
9.
Zurück zum Zitat Hutchinson MD, Gerstenfeld EP, Desjardins B, et al. Endocardial unipolar voltage mapping to detect epicardial ventricular tachycardia substrate in patients with nonischemic left ventricular cardiomyopathy. Circ Arrhythm Electrophysiol. 2011;4:49–55.CrossRefPubMed Hutchinson MD, Gerstenfeld EP, Desjardins B, et al. Endocardial unipolar voltage mapping to detect epicardial ventricular tachycardia substrate in patients with nonischemic left ventricular cardiomyopathy. Circ Arrhythm Electrophysiol. 2011;4:49–55.CrossRefPubMed
10.
Zurück zum Zitat Polin GM, Haqqani H, Tzou W, et al. Endocardial unipolar voltage mapping to identify epicardial substrate in arrhythmogenic right ventricular cardiomyopathy/dysplasia. Heart Rhythm. 2011;8:76–83.CrossRefPubMed Polin GM, Haqqani H, Tzou W, et al. Endocardial unipolar voltage mapping to identify epicardial substrate in arrhythmogenic right ventricular cardiomyopathy/dysplasia. Heart Rhythm. 2011;8:76–83.CrossRefPubMed
11.
Zurück zum Zitat Stevenson WG, Friedman PL, Sager PT, et al. Exploring postinfarction reentrant ventricular tachycardia with entrainment mapping. J Am Coll Cardiol. 1997;29:1180–9.CrossRefPubMed Stevenson WG, Friedman PL, Sager PT, et al. Exploring postinfarction reentrant ventricular tachycardia with entrainment mapping. J Am Coll Cardiol. 1997;29:1180–9.CrossRefPubMed
12.
Zurück zum Zitat Irie T, Yu R, Bradfield JS, et al. Relationship between sinus rhythm late activation zones and critical sites for scar-related ventricular tachycardia: systematic analysis of isochronal late activation mapping. Circ Arrhythm Electrophysiol. 2015;8:390–9.CrossRefPubMedPubMedCentral Irie T, Yu R, Bradfield JS, et al. Relationship between sinus rhythm late activation zones and critical sites for scar-related ventricular tachycardia: systematic analysis of isochronal late activation mapping. Circ Arrhythm Electrophysiol. 2015;8:390–9.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Viswanathan K, Mantziari L, Butcher C, et al. Evaluation of a novel high-resolution mapping system for catheter ablation of ventricular arrhythmias. Heart Rhythm. 2017;14:176–83.CrossRefPubMed Viswanathan K, Mantziari L, Butcher C, et al. Evaluation of a novel high-resolution mapping system for catheter ablation of ventricular arrhythmias. Heart Rhythm. 2017;14:176–83.CrossRefPubMed
14.
Zurück zum Zitat Acosta J, Penela D, Andreu D, et al. Multielectrode vs. point-by-point mapping for ventricular tachycardia substrate ablation: a randomized study. Europace. 2018;20:512–9.CrossRefPubMed Acosta J, Penela D, Andreu D, et al. Multielectrode vs. point-by-point mapping for ventricular tachycardia substrate ablation: a randomized study. Europace. 2018;20:512–9.CrossRefPubMed
15.
Zurück zum Zitat Di Biase L, Burkhardt JD, Lakkireddy D, et al. Ablation of stable VTs versus substrate ablation in ischemic cardiomyopathy: the VISTA randomized multicenter trial. J Am Coll Cardiol. 2015;66:2872–82.CrossRefPubMed Di Biase L, Burkhardt JD, Lakkireddy D, et al. Ablation of stable VTs versus substrate ablation in ischemic cardiomyopathy: the VISTA randomized multicenter trial. J Am Coll Cardiol. 2015;66:2872–82.CrossRefPubMed
16.
Zurück zum Zitat Fernandez-Armenta J, Penela D, Acosta J, et al. Substrate modification or ventricular tachycardia induction, mapping, and ablation as the first step? A randomized study. Heart Rhythm. 2016;13:1589–95.CrossRefPubMed Fernandez-Armenta J, Penela D, Acosta J, et al. Substrate modification or ventricular tachycardia induction, mapping, and ablation as the first step? A randomized study. Heart Rhythm. 2016;13:1589–95.CrossRefPubMed
17.
Zurück zum Zitat Proietti R, Dowd R, Gee LV, et al. Impact of a high-density grid catheter on long-term outcomes for structural heart disease ventricular tachycardia ablation. J Interv Card Electrophysiol. 2021;62:519–29.CrossRefPubMedPubMedCentral Proietti R, Dowd R, Gee LV, et al. Impact of a high-density grid catheter on long-term outcomes for structural heart disease ventricular tachycardia ablation. J Interv Card Electrophysiol. 2021;62:519–29.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Sousa PA, Antonio N, Barra S, Elvas L, Goncalves L. Pattern matching filter and multielectrode mapping catheter - a new approach for complex premature ventricular contraction ablation. Rev Port Cardiol (Engl Ed). 2021;40:423–31.CrossRefPubMed Sousa PA, Antonio N, Barra S, Elvas L, Goncalves L. Pattern matching filter and multielectrode mapping catheter - a new approach for complex premature ventricular contraction ablation. Rev Port Cardiol (Engl Ed). 2021;40:423–31.CrossRefPubMed
19.
Zurück zum Zitat Martins RP, Benali K, Galand V, et al. Ablation of multifocal premature ventricular contractions using automated pace-mapping software. Rev Port Cardiol. 2022;41:653–62.CrossRefPubMed Martins RP, Benali K, Galand V, et al. Ablation of multifocal premature ventricular contractions using automated pace-mapping software. Rev Port Cardiol. 2022;41:653–62.CrossRefPubMed
Metadaten
Titel
Substrate and arrhythmia characterization using the multi-electrode Optrell mapping catheter for ventricular arrhythmia ablation—a single-center experience
verfasst von
Jian Liang Tan
Gustavo S. Guandalini
Matthew C. Hyman
Jeffrey Arkles
Pasquale Santangeli
Robert D. Schaller
Fermin Garcia
Gregory Supple
David S. Frankel
Saman Nazarian
David Lin
David Callans
Francis E. Marchlinski
Timothy M. Markman
Publikationsdatum
18.08.2023
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2024
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-023-01618-5

Weitere Artikel der Ausgabe 3/2024

Journal of Interventional Cardiac Electrophysiology 3/2024 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.