Skip to main content
Erschienen in: Pediatric Radiology 11/2023

25.07.2023 | Original Article

Ultra-low-dose computed tomography with deep learning reconstruction for craniosynostosis at radiation doses comparable to skull radiographs: a pilot study

verfasst von: Youngwook Lyoo, Young Hun Choi, Seul Bi Lee, Seunghyun Lee, Yeon Jin Cho, Su-Mi Shin, Ji Hoon Phi, Seung Ki Kim, Jung-Eun Cheon

Erschienen in: Pediatric Radiology | Ausgabe 11/2023

Einloggen, um Zugang zu erhalten

Abstract

Background

Craniofacial computed tomography (CT) is the diagnostic investigation of choice for craniosynostosis, but high radiation dose remains a concern.

Objective

To evaluate the image quality and diagnostic performance of an ultra-low-dose craniofacial CT protocol with deep learning reconstruction for diagnosis of craniosynostosis.

Materials and methods

All children who underwent initial craniofacial CT for suspected craniosynostosis between September 2021 and September 2022 were included in the study. The ultra-low-dose craniofacial CT protocol using 70 kVp, model-based iterative reconstruction and deep learning reconstruction techniques was compared with a routine-dose craniofacial CT protocol. Quantitative analysis of the signal-to-noise ratio and noise was performed. The 3-dimensional (D) volume-rendered images were independently evaluated by two radiologists with regard to surface coarseness, step-off artifacts and overall image quality on a 5-point scale. Sutural patency was assessed for each of six sutures. Radiation dose was compared between the two protocols.

Results

Among 29 patients (15 routine-dose CT and 14 ultra-low-dose CT), 23 patients had craniosynostosis. The 3-D volume-rendered images of ultra-low-dose CT without deep learning showed decreased image quality compared to routine-dose CT. The 3-D volume-rendered images of ultra-low-dose CT with deep learning reconstruction showed higher noise level, higher surface coarseness but decreased step-off artifacts, comparable signal-to-noise ratio and overall similar image quality compared to the routine-dose CT images. Diagnostic performance for detecting craniosynostosis at the suture level showed no significant difference between ultra-low-dose CT without deep learning reconstruction, ultra-low-dose CT with deep learning reconstruction and routine-dose CT. The estimated effective radiation dose for the ultra-low-dose CT was 0.05 mSv (range, 0.03–0.06 mSv), a 95% reduction in dose over the routine-dose CT at 1.15 mSv (range, 0.54–1.74 mSv). This radiation dose is comparable to 4-view skull radiography (0.05–0.1 mSv) and lower than previously reported effective dose for craniosynostosis protocols (0.08–3.36 mSv).

Conclusion

In this pilot study, an ultra-low-dose CT protocol using radiation doses at a level similar to skull radiographs showed preserved diagnostic performance for craniosynostosis, but decreased image quality compared to the routine-dose CT protocol. However, by combining the ultra-low-dose CT protocol with deep learning reconstruction, image quality was improved to a level comparable to the routine-dose CT protocol, without sacrificing diagnostic performance for craniosynostosis.

Graphical Abstract

Literatur
1.
Zurück zum Zitat Boulet SL, Rasmussen SA, Honein MA (2008) A population-based study of craniosynostosis in metropolitan Atlanta, 1989–2003. Am J Med Genet A 146:984–991CrossRef Boulet SL, Rasmussen SA, Honein MA (2008) A population-based study of craniosynostosis in metropolitan Atlanta, 1989–2003. Am J Med Genet A 146:984–991CrossRef
3.
Zurück zum Zitat Vannier MW, Hildebolt CF, Marsh JL et al (1989) Craniosynostosis: diagnostic value of three-dimensional CT reconstruction. Radiology 173:669–673CrossRefPubMed Vannier MW, Hildebolt CF, Marsh JL et al (1989) Craniosynostosis: diagnostic value of three-dimensional CT reconstruction. Radiology 173:669–673CrossRefPubMed
4.
Zurück zum Zitat Kirmi O, Lo SJ, Johnson D et al (2009) Craniosynostosis: a radiological and surgical perspective. Semin Ultrasound CT MR 30:492–512CrossRefPubMed Kirmi O, Lo SJ, Johnson D et al (2009) Craniosynostosis: a radiological and surgical perspective. Semin Ultrasound CT MR 30:492–512CrossRefPubMed
5.
Zurück zum Zitat Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36:146–153CrossRefPubMedPubMedCentral Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36:146–153CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Schweitzer T, Böhm H, Meyer-Marcotty P et al (2012) Avoiding CT scans in children with single-suture craniosynostosis. Childs Nerv Syst 28:1077–1082CrossRefPubMed Schweitzer T, Böhm H, Meyer-Marcotty P et al (2012) Avoiding CT scans in children with single-suture craniosynostosis. Childs Nerv Syst 28:1077–1082CrossRefPubMed
7.
Zurück zum Zitat Hamard A, Greffier J, Bastide S et al (2021) Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy. Eur Radiol 31:2621–2633CrossRefPubMed Hamard A, Greffier J, Bastide S et al (2021) Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy. Eur Radiol 31:2621–2633CrossRefPubMed
8.
Zurück zum Zitat Tsiflikas I, Thater G, Ayx I et al (2023) Low dose pediatric chest computed tomography on a photon counting detector system–initial clinical experience. Ped Radiol 13:1–6 Tsiflikas I, Thater G, Ayx I et al (2023) Low dose pediatric chest computed tomography on a photon counting detector system–initial clinical experience. Ped Radiol 13:1–6
9.
Zurück zum Zitat Miéville FA, Berteloot L, Grandjean A et al (2013) Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis. Ped Radiol 43:558–567CrossRef Miéville FA, Berteloot L, Grandjean A et al (2013) Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis. Ped Radiol 43:558–567CrossRef
10.
Zurück zum Zitat Rob S, Bryant T, Wilson I et al (2017) Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature. Clin Radiol 72:11–15CrossRefPubMed Rob S, Bryant T, Wilson I et al (2017) Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature. Clin Radiol 72:11–15CrossRefPubMed
11.
Zurück zum Zitat McLaughlin PD, Ouellette HA, Louis LJ et al (2013) (2013) The emergence of ultra-low–dose computed tomography and the impending obsolescence of the plain radiograph? Can Assoc Radiol J 64:314–318CrossRefPubMed McLaughlin PD, Ouellette HA, Louis LJ et al (2013) (2013) The emergence of ultra-low–dose computed tomography and the impending obsolescence of the plain radiograph? Can Assoc Radiol J 64:314–318CrossRefPubMed
12.
Zurück zum Zitat Park JE, Choi YH, Cheon JE et al (2017) Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp. Pediatr Radiol 47:710–717CrossRefPubMed Park JE, Choi YH, Cheon JE et al (2017) Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp. Pediatr Radiol 47:710–717CrossRefPubMed
13.
Zurück zum Zitat Niemann T, Henry S, Duhamel A et al (2014) Pediatric chest CT at 70 kVp: a feasibility study in 129 children. Pediatr Radiol 44:1347–1357CrossRefPubMed Niemann T, Henry S, Duhamel A et al (2014) Pediatric chest CT at 70 kVp: a feasibility study in 129 children. Pediatr Radiol 44:1347–1357CrossRefPubMed
14.
Zurück zum Zitat Ryu YJ, Choi YH, Cheon JE et al (2016) Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom. Pediatr Radiol 46:303–315CrossRefPubMed Ryu YJ, Choi YH, Cheon JE et al (2016) Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom. Pediatr Radiol 46:303–315CrossRefPubMed
15.
Zurück zum Zitat Montoya JC, Eckel LJ, DeLone DR et al (2017) Low-dose CT for craniosynostosis: preserving diagnostic benefit with substantial radiation dose reduction. Am J Neuroradiol 38:672–677CrossRefPubMedPubMedCentral Montoya JC, Eckel LJ, DeLone DR et al (2017) Low-dose CT for craniosynostosis: preserving diagnostic benefit with substantial radiation dose reduction. Am J Neuroradiol 38:672–677CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Barreto IL, Tuna IS, Rajderkar DA et al (2022) PEDR Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality Pediatr Radiol 52:85–96 Barreto IL, Tuna IS, Rajderkar DA et al (2022) PEDR Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality Pediatr Radiol 52:85–96
17.
Zurück zum Zitat Ernst CW, Hustaert TL, Belsack D et al (2016) Dedicated sub 0.1 mSv RCT using MBIR in children with suspected craniosynostosis: quality assessment. Eur Radiol 26:892–899CrossRefPubMed Ernst CW, Hustaert TL, Belsack D et al (2016) Dedicated sub 0.1 mSv RCT using MBIR in children with suspected craniosynostosis: quality assessment. Eur Radiol 26:892–899CrossRefPubMed
18.
Zurück zum Zitat Hong JH, Park EA, Lee W et al (2020) Incremental image noise reduction in coronary CT angiography using a deep learning-based technique with iterative reconstruction. Korean J Radiol 21:1165CrossRefPubMedPubMedCentral Hong JH, Park EA, Lee W et al (2020) Incremental image noise reduction in coronary CT angiography using a deep learning-based technique with iterative reconstruction. Korean J Radiol 21:1165CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Lim WH, Choi YH, Park JE et al (2019) Application of vendor-neutral iterative reconstruction technique to pediatric abdominal computed tomography. Korean J Radiol 20:1358–1367CrossRefPubMedPubMedCentral Lim WH, Choi YH, Park JE et al (2019) Application of vendor-neutral iterative reconstruction technique to pediatric abdominal computed tomography. Korean J Radiol 20:1358–1367CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Kolb M, Storz C, Kim JH et al (2019) Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis. Eur J Radiol 116:198–204CrossRefPubMed Kolb M, Storz C, Kim JH et al (2019) Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis. Eur J Radiol 116:198–204CrossRefPubMed
21.
Zurück zum Zitat Vu HL, Panchal J, Parker EE et al (2001) The timing of physiologic closure of the metopic suture: a review of 159 patients using reconstructed 3-D CT scans of the craniofacial region. J Craniofac Surg 12:527–532CrossRefPubMed Vu HL, Panchal J, Parker EE et al (2001) The timing of physiologic closure of the metopic suture: a review of 159 patients using reconstructed 3-D CT scans of the craniofacial region. J Craniofac Surg 12:527–532CrossRefPubMed
22.
Zurück zum Zitat Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158–166CrossRefPubMed Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158–166CrossRefPubMed
23.
Zurück zum Zitat Mazonakis M, Damilakis J, Raissaki M et al (2004) Radiation dose and cancer risk to children undergoing skull radiography. Pediatr Radiol 34:624–629CrossRefPubMed Mazonakis M, Damilakis J, Raissaki M et al (2004) Radiation dose and cancer risk to children undergoing skull radiography. Pediatr Radiol 34:624–629CrossRefPubMed
24.
Zurück zum Zitat Brindhaban A, Eze CU (2006) Estimation of radiation dose during diagnostic x-ray examinations of newborn babies and 1-year-old infants. Med Princ Pract 15(2):60–265 Brindhaban A, Eze CU (2006) Estimation of radiation dose during diagnostic x-ray examinations of newborn babies and 1-year-old infants. Med Princ Pract 15(2):60–265
25.
Zurück zum Zitat Vassileva J, Rehani M, Kostova-Lefterova D et al (2015) A study to establish international diagnostic reference levels for paediatric computed tomography. Radiat Prot Dosimetry 165:70–80CrossRefPubMed Vassileva J, Rehani M, Kostova-Lefterova D et al (2015) A study to establish international diagnostic reference levels for paediatric computed tomography. Radiat Prot Dosimetry 165:70–80CrossRefPubMed
26.
Zurück zum Zitat Badve CA, Mallikarjunappa MK, Iyer RS et al (2013) Craniosynostosis: imaging review and primer on computed tomography. Pediatr Radiol 43:728–742CrossRefPubMed Badve CA, Mallikarjunappa MK, Iyer RS et al (2013) Craniosynostosis: imaging review and primer on computed tomography. Pediatr Radiol 43:728–742CrossRefPubMed
27.
Zurück zum Zitat Vazquez JL, Pombar MA, Pumar JM et al (2013) Optimised low-dose multidetector CT protocol for children with cranial deformity. Eur Radiol 23:2279–2287CrossRefPubMed Vazquez JL, Pombar MA, Pumar JM et al (2013) Optimised low-dose multidetector CT protocol for children with cranial deformity. Eur Radiol 23:2279–2287CrossRefPubMed
28.
Zurück zum Zitat Neverauskiene A, Maciusovic M, Burkanas M et al (2018) Image based simulation of the low dose computed tomography images suggests 13 mAs 120 kV suitability for non-syndromic craniosynostosis diagnosis without iterative reconstruction algorithms. Eur J Radiol 105:168–174CrossRefPubMed Neverauskiene A, Maciusovic M, Burkanas M et al (2018) Image based simulation of the low dose computed tomography images suggests 13 mAs 120 kV suitability for non-syndromic craniosynostosis diagnosis without iterative reconstruction algorithms. Eur J Radiol 105:168–174CrossRefPubMed
29.
Zurück zum Zitat Kaasalainen T, Palmu K, Lampinen A et al (2015) Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction. Pediatr Radiol 45:1544–1553CrossRefPubMed Kaasalainen T, Palmu K, Lampinen A et al (2015) Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction. Pediatr Radiol 45:1544–1553CrossRefPubMed
30.
Zurück zum Zitat Dalehaug I, Bolstad KN, Aadnevik D et al (2017) ADMIRE vs. SAFIRE: Objective comparison of CT reconstruction algorithms and their noise properties. arXiv preprint arXiv: 1708.09616. [Online]. Available: https://arxiv.org/abs/1708.09616. Accessed on Dec 7th, 2022 Dalehaug I, Bolstad KN, Aadnevik D et al (2017) ADMIRE vs. SAFIRE: Objective comparison of CT reconstruction algorithms and their noise properties. arXiv preprint arXiv: 1708.09616. [Online]. Available: https://​arxiv.​org/​abs/​1708.​09616. Accessed on Dec 7th, 2022
Metadaten
Titel
Ultra-low-dose computed tomography with deep learning reconstruction for craniosynostosis at radiation doses comparable to skull radiographs: a pilot study
verfasst von
Youngwook Lyoo
Young Hun Choi
Seul Bi Lee
Seunghyun Lee
Yeon Jin Cho
Su-Mi Shin
Ji Hoon Phi
Seung Ki Kim
Jung-Eun Cheon
Publikationsdatum
25.07.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 11/2023
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-023-05717-3

Weitere Artikel der Ausgabe 11/2023

Pediatric Radiology 11/2023 Zur Ausgabe

Hermes

Hermes

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.