Skip to main content
Erschienen in: Odontology 1/2024

05.06.2023 | Original Article

A mechanical and three-dimensional finite element study of the optimum tooth sectioning depth during the extraction of low-level horizontally impacted mandibular third molar

verfasst von: Wei Xu, Jie Shen, Kuncai Li, Tianqi Zhao, Binqing Xie, Junliang Chen, Yun He

Erschienen in: Odontology | Ausgabe 1/2024

Einloggen, um Zugang zu erhalten

Abstract

The present study aims to determine the optimum sectioning depth for the extraction of low-level horizontally impacted mandibular third molar (LHIM3M) using mechanical and finite element analysis. One hundred and fifty extracted mandibular third molars were randomly divided into three groups: 1, 2 or 3 mm of tooth tissue was retained at the bottom of the crown. The breaking force of teeth was tested in a universal strength testing machine. The fracture surface was observed and the type of tooth breakage was recorded. According to the three groups, corresponding 3D finite element models were created. The breaking force obtained in the mechanical study was, respectively, applied and the stress and strain of the teeth and surrounding tissues were analysed. Breaking force decreased as sectioning depth increased. The 2 mm group produced the lowest rate of incomplete breakage (10%). In the 2 mm model, the stresses were evenly distributed in the tooth tissue at the bottom of the fissure, and the maximal stress was located in the tissue close to the root segment. The maximum values of stresses in the bone and of strains in the periodontal ligament of the second molar and bone were lower in the 1 mm model than in other models. Their distribution was similar in the three models. A sectioning depth of 1 mm group saves labour during the extraction of LHIM3M, compared to 2 and 3 mm; 2 mm might be the appropriate sectioning depth in terms of breakage shapes.
Literatur
1.
Zurück zum Zitat Lin D, Li Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms. J Mech Behav Biomed Mater. 2009;2(5):410–32.CrossRefPubMed Lin D, Li Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms. J Mech Behav Biomed Mater. 2009;2(5):410–32.CrossRefPubMed
2.
Zurück zum Zitat Blakey GH, Marciani RD, Haug RH, Phillips C, Offenbacher S, Pabla T, White RP Jr. Periodontal pathology associated with asymptomatic third molars. J Oral Maxillofac Surg. 2002;60(11):1227–33.CrossRefPubMed Blakey GH, Marciani RD, Haug RH, Phillips C, Offenbacher S, Pabla T, White RP Jr. Periodontal pathology associated with asymptomatic third molars. J Oral Maxillofac Surg. 2002;60(11):1227–33.CrossRefPubMed
3.
Zurück zum Zitat Campbell JH. Pathology associated with the third molar. Oral Maxillofac Surg Clin North Am. 2013;25(1):1–10.CrossRefPubMed Campbell JH. Pathology associated with the third molar. Oral Maxillofac Surg Clin North Am. 2013;25(1):1–10.CrossRefPubMed
4.
Zurück zum Zitat Carmichael FA, McGowan DA. Incidence of nerve damage following third molar removal: a West of Scotland oral surgery research group study. Br J Oral Maxillofac Surg. 1992;30(2):78–82.CrossRefPubMed Carmichael FA, McGowan DA. Incidence of nerve damage following third molar removal: a West of Scotland oral surgery research group study. Br J Oral Maxillofac Surg. 1992;30(2):78–82.CrossRefPubMed
5.
Zurück zum Zitat Gülicher D, Gerlach KL. Sensory impairment of the lingual and inferior alveolar nerves following removal of impacted mandibular third molars. Int J Oral Maxillofac Surg. 2001;30(4):306–12.CrossRefPubMed Gülicher D, Gerlach KL. Sensory impairment of the lingual and inferior alveolar nerves following removal of impacted mandibular third molars. Int J Oral Maxillofac Surg. 2001;30(4):306–12.CrossRefPubMed
6.
Zurück zum Zitat Luo SY. Video atlas of impacted wisdom tooth extraction—turbo drilling method. People Med Publ House. 2018;2018:9787117268851. Luo SY. Video atlas of impacted wisdom tooth extraction—turbo drilling method. People Med Publ House. 2018;2018:9787117268851.
7.
Zurück zum Zitat Eraslan O, Sevimay M, Usumez A, Eskitascioglu G. Effects of cantilever design and material on stress distribution in fixed partial dentures—a finite element analysis. J Oral Rehabil. 2005;32(4):273–8.CrossRefPubMed Eraslan O, Sevimay M, Usumez A, Eskitascioglu G. Effects of cantilever design and material on stress distribution in fixed partial dentures—a finite element analysis. J Oral Rehabil. 2005;32(4):273–8.CrossRefPubMed
8.
Zurück zum Zitat Couegnat G, Fok SL, Cooper JE, Qualtrough AJ. Structural optimization of dental restorations using the principle of adaptive growth. Dent Mater. 2006;22(1):3–12.CrossRefPubMed Couegnat G, Fok SL, Cooper JE, Qualtrough AJ. Structural optimization of dental restorations using the principle of adaptive growth. Dent Mater. 2006;22(1):3–12.CrossRefPubMed
9.
Zurück zum Zitat Qian Y, Fan Y, Liu Z, Zhang M. Numerical simulation of tooth movement in a therapy period. Clin Biomech (Bristol, Avon). 2008;23(Suppl 1):S48-52.CrossRefPubMed Qian Y, Fan Y, Liu Z, Zhang M. Numerical simulation of tooth movement in a therapy period. Clin Biomech (Bristol, Avon). 2008;23(Suppl 1):S48-52.CrossRefPubMed
10.
Zurück zum Zitat Varvara G, Bernardi S, Cutilli T, Bianchi S, Sinjari B, Piattelli M. Anti-inflammatory steroid use in impacted third molar surgery: a systematic review. J Biol Regul Homeost Agents. 2017;31(4):1095–9.PubMed Varvara G, Bernardi S, Cutilli T, Bianchi S, Sinjari B, Piattelli M. Anti-inflammatory steroid use in impacted third molar surgery: a systematic review. J Biol Regul Homeost Agents. 2017;31(4):1095–9.PubMed
11.
Zurück zum Zitat Li D, Wei Z, Zhang W, Li Z. Crown cutting mode selection in extracting the mandible third molar by dental drilling system. Zhonghua Kou Qiang Yi Xue Za Zhi. 2014;49(9):521–4.PubMed Li D, Wei Z, Zhang W, Li Z. Crown cutting mode selection in extracting the mandible third molar by dental drilling system. Zhonghua Kou Qiang Yi Xue Za Zhi. 2014;49(9):521–4.PubMed
12.
Zurück zum Zitat Liao R, Jiang X, Wang R, Li X, Zheng Q, Huang H. Removal of horizontally impacted mandibular third molars with large root bifurcations using a modified tooth sectioning method. J Oral Maxillofac Surg. 2021;79(4):748-755.e1.CrossRefPubMed Liao R, Jiang X, Wang R, Li X, Zheng Q, Huang H. Removal of horizontally impacted mandibular third molars with large root bifurcations using a modified tooth sectioning method. J Oral Maxillofac Surg. 2021;79(4):748-755.e1.CrossRefPubMed
13.
Zurück zum Zitat Zheng X, Lin X, Wang Z. Extraction of low horizontally and buccally impacted mandibular third molars by three-piece tooth sectioning. Br J Oral Maxillofac Surg. 2020;58(7):829–33.CrossRefPubMed Zheng X, Lin X, Wang Z. Extraction of low horizontally and buccally impacted mandibular third molars by three-piece tooth sectioning. Br J Oral Maxillofac Surg. 2020;58(7):829–33.CrossRefPubMed
14.
Zurück zum Zitat Pessoa RS, Coelho PG, Muraru L, Marcantonio E Jr, Vaz LG, Vander Sloten J, Jaecques SV. Influence of implant design on the biomechanical environment of immediately placed implants: computed tomography-based nonlinear three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2011;26(6):1279–87.PubMed Pessoa RS, Coelho PG, Muraru L, Marcantonio E Jr, Vaz LG, Vander Sloten J, Jaecques SV. Influence of implant design on the biomechanical environment of immediately placed implants: computed tomography-based nonlinear three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2011;26(6):1279–87.PubMed
16.
Zurück zum Zitat Murakami N, Wakabayashi N. Finite element contact analysis as a critical technique in dental biomechanics: a review. J Prosthodont Res. 2014;58(2):92–101.CrossRefPubMed Murakami N, Wakabayashi N. Finite element contact analysis as a critical technique in dental biomechanics: a review. J Prosthodont Res. 2014;58(2):92–101.CrossRefPubMed
17.
Zurück zum Zitat Fiorillo L, Cicciù M, D’Amico C, Mauceri R, Oteri G, Cervino G. Finite element method and von mises investigation on bone response to dynamic stress with a novel conical dental implant connection. Biomed Res Int. 2020;2020:2976067.CrossRefPubMedPubMedCentral Fiorillo L, Cicciù M, D’Amico C, Mauceri R, Oteri G, Cervino G. Finite element method and von mises investigation on bone response to dynamic stress with a novel conical dental implant connection. Biomed Res Int. 2020;2020:2976067.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Lisiak-Myszke M, Marciniak D, Bieliński M, Sobczak H, Garbacewicz Ł, Drogoszewska B. Application of finite element analysis in oral and maxillofacial surgery-a literature review. Materials (Basel). 2020;13(14):3063.CrossRefPubMed Lisiak-Myszke M, Marciniak D, Bieliński M, Sobczak H, Garbacewicz Ł, Drogoszewska B. Application of finite element analysis in oral and maxillofacial surgery-a literature review. Materials (Basel). 2020;13(14):3063.CrossRefPubMed
19.
Zurück zum Zitat Liu YF, Wang R, Baur DA, Jiang XF. A finite element analysis of the stress distribution to the mandible from impact forces with various orientations of third molars. J Zhejiang Univ Sci B. 2018;19(1):38–48.CrossRefPubMedPubMedCentral Liu YF, Wang R, Baur DA, Jiang XF. A finite element analysis of the stress distribution to the mandible from impact forces with various orientations of third molars. J Zhejiang Univ Sci B. 2018;19(1):38–48.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Antic S, Vukicevic AM, Milasinovic M, Saveljic I, Jovicic G, Filipovic N, Rakocevic Z, Djuric M. Impact of the lower third molar presence and position on the fragility of mandibular angle and condyle: a three-dimensional finite element study. J Craniomaxillofac Surg. 2015;43(6):870–8.CrossRefPubMed Antic S, Vukicevic AM, Milasinovic M, Saveljic I, Jovicic G, Filipovic N, Rakocevic Z, Djuric M. Impact of the lower third molar presence and position on the fragility of mandibular angle and condyle: a three-dimensional finite element study. J Craniomaxillofac Surg. 2015;43(6):870–8.CrossRefPubMed
Metadaten
Titel
A mechanical and three-dimensional finite element study of the optimum tooth sectioning depth during the extraction of low-level horizontally impacted mandibular third molar
verfasst von
Wei Xu
Jie Shen
Kuncai Li
Tianqi Zhao
Binqing Xie
Junliang Chen
Yun He
Publikationsdatum
05.06.2023
Verlag
Springer Nature Singapore
Erschienen in
Odontology / Ausgabe 1/2024
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-023-00822-z

Weitere Artikel der Ausgabe 1/2024

Odontology 1/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.