Skip to main content
Erschienen in: Journal of Robotic Surgery 1/2024

01.12.2024 | Research

Mako versus ROSA: comparing surgical accuracy in robotic total knee arthroplasty

verfasst von: Harshadkumar D. Rajgor, Alistair Mayne, Chathura Munasinghe, Joseph Pagkalos, Yuvraj Agrawal, Edward T. Davis, Akash D. Sharma

Erschienen in: Journal of Robotic Surgery | Ausgabe 1/2024

Einloggen, um Zugang zu erhalten

Abstract

There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty. The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using intra-operative bony registration). The Mako knee system is an image-based system (using a pre-operative CT scan). This study aimed to compare surgical accuracy between the ROSA and Mako systems with specific reference to joint line height, patella height, posterior condylar offset and tibial slope. This was a retrospective review of a prospectively collected data of the initial 50 consecutive ROSA TKAs and the initial 50 consecutive Mako TKAs performed by two high-volume surgeons. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to joint line height (JLH), patella height (PH), tibial slope (TS) and posterior condylar offset (PCO). Mean difference between pre- and post-operative radiographs using the ROSA knee system of joint line height was 0.47 mm (SD 0.95) posterior condylar offset 0.16 mm (SD 0.76), tibial slope 0.9 degrees (SD 1.6) and patella height 0.01 (SD 0.05). Mean difference using the MAKO knee system of joint line height was 0.26 (SD 1.08), posterior condylar offset −0.26 mm (SD 0.78), tibial slope 1.8 degrees and patella height 0.03. No significant difference was demonstrated between the accuracy of component positioning of the ROSA or MAKO knee systems. Our study is the first study to compare the accuracy of the ROSA and MAKO knee systems in total knee arthroplasty. Both systems are highly accurate in restoring native posterior condylar offset, joint line height, tibial slope and patella height in TKA with no significant difference demonstrated between the two groups.
Literatur
3.
Zurück zum Zitat Culliford D, Maskell J, Judge A, Cooper C, Prieto-Alhambra D, Arden NK (2015) Future projections of total hip and knee arthroplasty in the UK: results from the UK Clinical Practice Research Datalink. Osteoarthr Cartil 23(4):594–600CrossRef Culliford D, Maskell J, Judge A, Cooper C, Prieto-Alhambra D, Arden NK (2015) Future projections of total hip and knee arthroplasty in the UK: results from the UK Clinical Practice Research Datalink. Osteoarthr Cartil 23(4):594–600CrossRef
4.
Zurück zum Zitat Muertizha M, Cai X, Ji B, Aimaiti A, Cao L (2022) Factors contributing to 1-year dissatisfaction after total knee arthroplasty: a nomogram prediction model. J Orthop Surg Res 17(1):367CrossRefPubMedPubMedCentral Muertizha M, Cai X, Ji B, Aimaiti A, Cao L (2022) Factors contributing to 1-year dissatisfaction after total knee arthroplasty: a nomogram prediction model. J Orthop Surg Res 17(1):367CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Brinkman J, Christopher Z, Moore M, Pollock J, Haglin JM, Bingham J (2022) Patient interest in robotic total joint arthroplasty is exponential: a 10-year Google trends analysis. Arthroplasty Today 15:13–18CrossRefPubMedPubMedCentral Brinkman J, Christopher Z, Moore M, Pollock J, Haglin JM, Bingham J (2022) Patient interest in robotic total joint arthroplasty is exponential: a 10-year Google trends analysis. Arthroplasty Today 15:13–18CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Sires JD, Craik JD, Wilson CJ (2021) Accuracy of bone resection in MAKO total knee robotic-assisted surgery. J Knee Surg 34(07):745–748CrossRefPubMed Sires JD, Craik JD, Wilson CJ (2021) Accuracy of bone resection in MAKO total knee robotic-assisted surgery. J Knee Surg 34(07):745–748CrossRefPubMed
9.
Zurück zum Zitat Kayani B, Konan S, Pietrzak JRT, Haddad FS (2018) Iatrogenic Bone and Soft Tissue Trauma in Robotic-Arm Assisted Total Knee Arthroplasty Compared with Conventional Jig-Based Total Knee Arthroplasty: A Prospective Cohort Study and Validation of a New Classification System. J Arthroplast 33:2496–2501CrossRef Kayani B, Konan S, Pietrzak JRT, Haddad FS (2018) Iatrogenic Bone and Soft Tissue Trauma in Robotic-Arm Assisted Total Knee Arthroplasty Compared with Conventional Jig-Based Total Knee Arthroplasty: A Prospective Cohort Study and Validation of a New Classification System. J Arthroplast 33:2496–2501CrossRef
10.
Zurück zum Zitat Parratte S, Price AJ, Jeys LM, Jackson WF, Clarke HD (2019) Accuracy of a new robotically assisted technique for total knee arthroplasty: a cadaveric study. J Arthroplasty 34:2799–2803CrossRefPubMed Parratte S, Price AJ, Jeys LM, Jackson WF, Clarke HD (2019) Accuracy of a new robotically assisted technique for total knee arthroplasty: a cadaveric study. J Arthroplasty 34:2799–2803CrossRefPubMed
11.
Zurück zum Zitat Shin C, Crovetti C, Huo E, Lionberger D (2022) Unsatisfactory accuracy of recent robotic assisting system ROSA for total knee arthroplasty. J Exp Orthop 9(1):82CrossRefPubMedPubMedCentral Shin C, Crovetti C, Huo E, Lionberger D (2022) Unsatisfactory accuracy of recent robotic assisting system ROSA for total knee arthroplasty. J Exp Orthop 9(1):82CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Figgie HE, Goldberg VM, Heiple KG, Moller HS, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis. J Bone Jt Surg––Ser A 68:1035CrossRef Figgie HE, Goldberg VM, Heiple KG, Moller HS, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis. J Bone Jt Surg––Ser A 68:1035CrossRef
15.
Zurück zum Zitat Clavé A, Le Henaff G, Roger T, Maisongrosse P, Mabit C, Dubrana F (2016) Joint line level in revision total knee replacement: assessment and functional results with an average of seven years follow-up. Int Orthop 40:1655–1662CrossRefPubMed Clavé A, Le Henaff G, Roger T, Maisongrosse P, Mabit C, Dubrana F (2016) Joint line level in revision total knee replacement: assessment and functional results with an average of seven years follow-up. Int Orthop 40:1655–1662CrossRefPubMed
16.
Zurück zum Zitat van Lieshout WA, Valkering KP, Koenraadt KL, van Etten-Jamaludin FS, Kerkhoffs GM, van Geenen RC (2019) The negative effect of joint line elevation after total knee arthroplasty on outcome. Knee Surg, Sports Traumatol, Arthroscopy 1(27):1477–1486CrossRef van Lieshout WA, Valkering KP, Koenraadt KL, van Etten-Jamaludin FS, Kerkhoffs GM, van Geenen RC (2019) The negative effect of joint line elevation after total knee arthroplasty on outcome. Knee Surg, Sports Traumatol, Arthroscopy 1(27):1477–1486CrossRef
18.
Zurück zum Zitat Goutham GD, Jain VK, Sinha S, Arya RK (2020) Effect of posterior condylar offset in post operative range of motion in cruciate retaining and sacrificing TKR: A comparative analysis. J Orthop 1(20):342–346CrossRef Goutham GD, Jain VK, Sinha S, Arya RK (2020) Effect of posterior condylar offset in post operative range of motion in cruciate retaining and sacrificing TKR: A comparative analysis. J Orthop 1(20):342–346CrossRef
19.
Zurück zum Zitat Meneghini RM, Ritter MA, Pierson JL, Meding JB, Berend ME, Faris PM (2006) The effect of the Insall-Salvati ratio on outcome after total knee arthroplasty. J Arthroplast 21(6 Suppl 2):116–120CrossRef Meneghini RM, Ritter MA, Pierson JL, Meding JB, Berend ME, Faris PM (2006) The effect of the Insall-Salvati ratio on outcome after total knee arthroplasty. J Arthroplast 21(6 Suppl 2):116–120CrossRef
21.
Metadaten
Titel
Mako versus ROSA: comparing surgical accuracy in robotic total knee arthroplasty
verfasst von
Harshadkumar D. Rajgor
Alistair Mayne
Chathura Munasinghe
Joseph Pagkalos
Yuvraj Agrawal
Edward T. Davis
Akash D. Sharma
Publikationsdatum
01.12.2024
Verlag
Springer London
Erschienen in
Journal of Robotic Surgery / Ausgabe 1/2024
Print ISSN: 1863-2483
Elektronische ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-023-01786-6

Weitere Artikel der Ausgabe 1/2024

Journal of Robotic Surgery 1/2024 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.