Skip to main content
Erschienen in: Clinical Research in Cardiology 9/2023

Open Access 02.05.2023 | Original Paper

Personalized diagnosis in suspected myocardial infarction

verfasst von: Johannes Tobias Neumann, Raphael Twerenbold, Francisco Ojeda, Sally J. Aldous, Brandon R. Allen, Fred S. Apple, Hugo Babel, Robert H. Christenson, Louise Cullen, Eleonora Di Carluccio, Dimitrios Doudesis, Ulf Ekelund, Evangelos Giannitsis, Jaimi Greenslade, Kenji Inoue, Tomas Jernberg, Peter Kavsak, Till Keller, Kuan Ken Lee, Bertil Lindahl, Thiess Lorenz, Simon A. Mahler, Nicholas L. Mills, Arash Mokhtari, William Parsonage, John W. Pickering, Christopher J. Pemberton, Christoph Reich, A. Mark Richards, Yader Sandoval, Martin P. Than, Betül Toprak, Richard W. Troughton, Andrew Worster, Tanja Zeller, Andreas Ziegler, Stefan Blankenberg, the ARTEMIS study group

Erschienen in: Clinical Research in Cardiology | Ausgabe 9/2023

Abstract

Background

In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hs-cTn)-based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays.

Methods

In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability (ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients.

Results

Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline-recommended strategy.

Conclusion

We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care.

Trial Registration numbers

Data of following cohorts were used for this project: BACC (www.​clinicaltrials.​gov; NCT02355457), stenoCardia (www.​clinicaltrials.​gov; NCT03227159), ADAPT-BSN (www.​australianclinic​altrials.​gov.​au; ACTRN12611001069943), IMPACT (www.​australianclinic​altrials.​gov.​au, ACTRN12611000206921), ADAPT-RCT (www.​anzctr.​org.​au; ANZCTR12610000766011), EDACS-RCT (www.​anzctr.​org.​au; ANZCTR12613000745741); DROP-ACS (https://​www.​umin.​ac.​jp, UMIN000030668); High-STEACS (www.​clinicaltrials.​gov; NCT01852123), LUND (www.​clinicaltrials.​gov; NCT05484544), RAPID-CPU (www.​clinicaltrials.​gov; NCT03111862), ROMI (www.​clinicaltrials.​gov; NCT01994577), SAMIE (https://​anzctr.​org.​au; ACTRN12621000053820), SEIGE and SAFETY (www.​clinicaltrials.​gov; NCT04772157), STOP-CP (www.​clinicaltrials.​gov; NCT02984436),
UTROPIA (www.​clinicaltrials.​gov; NCT02060760).

Graphical Abstract

Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1007/​s00392-023-02206-3.
Johannes Tobias Neumann, Raphael Twerenbold, Andreas Ziegler and Stefan Blankenberg contributed equally as first/last authors.

Introduction

Symptoms suggestive of myocardial infarction (MI) are a major reason for presentation to the emergency departments (ED) worldwide [1]. Measurement of cardiac troponin is crucial to diagnose or to rule out non-ST-elevation MI (NSTEMI) [2, 3]. For the management of patients with suspected NSTEMI, current guidelines recommend the application of high-sensitivity cardiac troponin (hs-cTn) assay-specific thresholds such as the 99th percentile or study-derived cut-offs for measurements obtained directly at presentation and, depending on the selected diagnostic approach, during serial sampling after one, two or three hours. [37]
Application of fixed assay-specific hc-cTn thresholds combined with predefined time points of serial sampling remains challenging in busy emergency settings with globally widely differing patients’ characteristics. Besides, in the context of suspected NSTEMI, clinicians do not interpret hs-cTn concentrations and thresholds in isolation, but in combination with ECG findings and clinical characteristics, such as chest pain onset time, cardiovascular risk factors, age, sex, and other comorbidities, which are largely neglected in most current diagnostic algorithms [8]. Thus, a diagnostic algorithm, simultaneously including various variables such as hs-cTn concentrations, their dynamic change during flexibly timed resampling, ECG findings as well as most relevant and immediately available clinical variables, constitutes an unmet clinical need in patients with suspected MI, both in the ED and in the ambulatory care setting.
Based on prior work [9], we derived and validated a machine-learning model, which estimates the individual probability of NSTEMI in patients presenting with symptoms indicative of MI. This model accounts for immediately available confounding clinical variables, allows for flexible timing of potential serial sampling and can be applied using most established hs-cTn assays, including point-of-care assays. We aimed to prove its clinical application in patients with suspected NSTEMI and [1] defined the model’s overall diagnostic accuracy, [2] assessed the clinical performance according to MI probability thresholds in heterogeneous clinical conditions, and [3] finally compared the model’s clinical utility against currently recommended assay-specific thresholds. Overall, this work shall pave the way towards the routine clinical implementation of medical decision support systems to improve a rapid, efficient and safe diagnostic process in patients with suspected MI.

Methods

Study design and populations

In the “Artificial intelligence in suspected myocardial infarction study “ (ARTEMIS), we derived and externally validated diagnostic models by estimating the probability of MI using machine learning (probability machines) in adult patients presenting to the ED with symptoms suggestive of MI. We excluded patients presenting with ST-segment elevation MI. The overall study concept is displayed in Fig. 1. Briefly, probability machines for MI were derived in the BACC (Biomarkers in Acute Cardiac Care; NCT02355457) study, which is an ongoing prospective observational diagnostic study performed at the University Heart & Vascular Center Hamburg, Germany [10, 11]. The probability machines were then externally validated in the stenoCardia (Study for Evaluation of New Onset Chest Pain and Rapid Diagnosis of Myocardial Necrosis; NCT03227159) cohort, which prospectively enrolled patients with suspected acute coronary syndrome at the EDs of the University Medical Center Mainz, the Federal Armed Forces Hospital Koblenz, and University Hospital Hamburg-Eppendorf between 2007 and 2009 in an observational fashion [12, 13]. To confirm the generalizability and global applicability of the newly developed and validated diagnostic models in clinically and geographically widely varying settings, anonymized individual-level data of thirteen additional cohorts from nine countries and four continents were transferred to the University Medical Center Hamburg-Eppendorf, Germany, to centrally apply the diagnostic models on the harmonized data in the global generalization dataset (see Supplementary Appendix for detailed description).
All studies were carried out according to the principles of the Declaration of Helsinki and approved by the local ethics committees. Participation was voluntary; each patient gave written informed consent. The TRIPOD checklist for this study is provided in Table S1 in Supplementary Appendix.

Adjudication of final diagnosis

The primary outcome of this study was the diagnosis of NSTEMI at time of ED presentation, which included type 1 and type 2 MI. In the derivation and validation dataset, the final diagnosis of MI was adjudicated after patient discharge by two cardiologists independently considering all available clinical, imaging, electrocardiographic and hs-cTn information. Cases in which the two initial adjudicators disagreed were reviewed by a third cardiologist. Detailed information on the adjudication process in each cohort including the generalization dataset may be found in the Supplementary Appendix.

Outcome data

For prognostic evaluation, we collected data on incident MI, excluding the index events, as well as all-cause death within 30 days after ED presentation.

Troponin measurements

Concentrations of cardiac troponin was measured by five hs-cTnI assays (Architect® i2000 platform by Abbott; Atellica® IM platform by Siemens Healthineers; Atellica VTLi® point-of-care device by Siemens Healthineers; Access® platform by Beckman Coulter; PATHFAST® Analyser by PHC) and one hs-cTnT assay (Elecsys® Cobas e411 platform by Roche Diagnostics) in blood samples collected at time of ED presentation and serially thereafter as part of routine clinical care or in batches of samples that had been stored at  – 80 °C. Targeted timing of the second blood draw differed between the various participating studies and ranged from one to three hours. Time elapsed between serial study blood sampling in the ED was documented. Additional information regarding the hs-cTn assays used in all ARTEMIS study cohorts is provided in the Supplementary Appendix.

Clinical variables

In total, 18 patient-specific as well as hs-cTn-related variables readily available at time of ED presentation and all previously associated with myocardial infarction were considered for model development. The most important clinical variables were selected for the final model (see Supplementary Appendix).

Statistical analysis and model development

A detailed statistical description is provided in the Supplementary Appendix and summarized in Figure S1. Briefly, for each of the six hs-cTn assays studied, we derived, validated, and globally applied two machine-learning diagnostic models, which estimate the individual probability of an acute MI in individuals presenting to the ED with suspected MI: One model was based on a single hs-cTn measurement obtained at time of ED presentation, the second model on two serial hs-cTn measurements. Modeling steps in the model derivation phase included multiple imputation of missing co-variables, cross-validation in all modeling and variable selection steps, and combination of multiple machines in a super learner with equal weights. Probability estimates of the super learner were calibrated in all validation and generalization studies.
The diagnostic performance of the models across the spectrum of possible MI probability thresholds was evaluated in one percent increments. Diagnostic performance measures were obtained from random effect meta-analyses and included negative and positive predictive value (NPV and PPV), sensitivity and specificity, proportion of patients below or above a given MI probability threshold as well as corresponding 30-day incidence of MI or death. Resulting tables and figures could be used to identify patients at low risk of MI suitable for outpatient management or those at high risk who are suitable to inpatient or invasive strategies. To illustrate the clinical applicability and to contrast the performance of the novel diagnostic model with the current state of the art approach, we compared the diagnostic performance measures of our diagnostic model with the 0 h, 0/1 h and 0/2 h strategy recommended by the ESC guideline [4].
To make the algorithm readily available and applicable to clinicians, a mobile application is currently constructed based on the present models, which are easily transferable to other systems. In a mid-term perspective, semi-automated integration of the diagnostic models into the local electronic health record systems as a medical support system is envisioned.
All statistical analyses were performed in R version 4.2.0 [14].

Results

Study populations

The models were developed in 2575 patients with suspected MI in the derivation cohort BACC and then applied in 1688 patients of the validation cohort stenoCardia as well as in 23,411 patients of the global generalization dataset. Baseline characteristics of the derivation, validation and global generalization cohorts can be found in Table 1 and Tables S2, S3, S4, S5. In the overall dataset, median age was 61 [50,73] years, 55.8% were male and 46.1% presented to the ED within the first three hours after symptom onset. Prevalence of MI ranged from 5.5 to 16.8% across the study cohorts. During follow-up, 643 (2.7%) incident cardiovascular death and 1007 Mis (4.8%) were observed.
Table 1
Baseline characteristics for derivation, validation, and generalization cohorts
 
All patients
Derivation
Validation
Global generalization
Sample size
27,674
2575
1688
23,411
Age (years)
61.0 [50.0, 73.0]
64.0 [51.0, 75.0]
63.0 [52.0, 72.0]
61.0 [50.0, 73.0]
Sex (male) (%)
15,451 (55.8)
1638 (63.6)
1108 (65.6)
12,705 (54.3)
Heart rate (bpm)
76.0 [66.0, 88.0]
77.0 [67.0, 88.5]
70.0 [62.0, 81.0]
76.0 [66.0, 88.0]
Systolic BP (mmHg)
143.0 [128.0, 160.0]
147.0 [131.0, 163.0]
140.0 [129.0, 160.0]
143.0 [128.0, 160.0]
eGFR (mL/min for 1.73m2)
82.9 [63.4, 96.9]
76.9 [58.5, 92.3]
84.2 [69.0, 95.2]
83.4 [63.7, 97.4]
History of CAD (%)
8203 (29.8)
872 (33.9)
606 (36.9)
6725 (28.9)
History of heart failure (%)
2588 (11.5)
394 (15.3)
120 (7.5)
2074 (11.3)
History of atrial fibrillation (%)
1859 (13.0)
395 (15.3)
162 (9.8)
1302 (12.9)
Hypertension (%)
16,127 (59.0)
1681 (65.5)
1256 (74.4)
13,190 (57.1)
Hyperlipoproteinemia (%)
12,837 (48.4)
904 (35.1)
1236 (73.2)
10,697 (48.1)
Diabetes (%)
5404 (19.8)
326 (12.8)
303 (18.2)
4775 (20.7)
Ever smoker (%)
10,796 (43.1)
1187 (46.8)
865 (52.6)
8744 (42.0)
Family history of CAD (%)
8476 (40.0)
478 (19.3)
540 (33.2)
7458 (43.7)
Ischemic signs ECG (%)
4428 (18.4)
520 (20.8)
872 (52.1)
3036 (15.3)
Symptom onset < 3 h (%)
11,122 (46.1)
713 (29.4)
631 (37.4)
9778 (48.9)
Time between serial samples (min)
80.0 [60.0, 155.0]
60.0 [60.0, 63.0]
180.0 [162.0, 190.0]
90.0 [60.0, 148.0]
Final diagnosis of NSTEMI (%)
3249 (11.7)
368 (14.3)
283 (16.8)
2598 (11.1)
Follow-up cardiovascular death (%)
643 (2.7)
74 (3.4)
38 (2.3)
531 (2.7)
Follow-up MI (%)
1007 (4.8)
24 (1.1)
47 (2.8)
936 (5.5)
Hs-cTnI Access- First measurement (ng/L)
3.5 [2.3, 8.3]
5.3 [2.9, 15.8]
5.2 [2.3, 23.1]
3.0 [2.3, 6.0]
Hs-cTnI Access—Second measurement (ng/L)
4.0 [2.3, 10.3]
5.8 [3.0, 19.7]
7.2 [3.2, 38.6]
3.0 [2.3, 6.5]
Hs-cTnI Architect- First measurement (ng/L)
4.5 [2.0, 14.0]
5.7 [2.6, 16.1]
6.9 [3.5, 28.8]
4.0 [2.0, 12.0]
Hs-cTnI Architect—Second measurement (ng/L)
5.0 [2.2, 16.3]
5.9 [2.6, 19.4]
7.8 [3.6, 35.8]
4.1 [2.0, 14.0]
Hs-cTnI Atellica—First measurement (ng/L)
5.3 [2.5, 17.4]
5.7 [2.5, 19.9]
6.4 [3.0, 31.2]
4.8 [2.5, 14.6]
Hs-cTnI Atellica- Second measurement (ng/L)
6.4 [2.9, 22.0]
6.2 [2.7, 23.9]
8.0 [3.5, 41.2]
6.0 [2.8, 18.8]
Hs-cTnI Atellica VTLi- First measurement (ng/L)
7.6 [4.1, 16.0]
6.3 [3.8, 11.5]
-
7.8 [4.1, 16.8]
Hs-cTnI Atellica VTLi- Second measurement (ng/L)
7.9 [4.1, 17.2]
6.0 [3.8, 12.5]
-
8.2 [4.2, 18.4]
Hs-cTnT Elecsys—First measurement (ng/L)
9.0 [5.0, 20.0]
9.0 [5.0, 21.0]
9.2 [5.0, 20.3]
8.6 [5.0, 20.0]
Hs-cTnT Elecsys—Second measurement (ng/L)
9.0 [5.0, 22.0]
9.0 [5.0, 23.0]
8.1 [4.1, 23.3]
8.8 [5.0, 22.0]
Hs-cTnI Pathfast- First measurement (ng/L)
4.0 [2.3, 12.4]
3.7 [2.3, 12.2]
4.2 [2.3, 12.8]
-
Hs-cTnI Pathfast- Second measurement (ng/L)
4.3 [2.3, 15.5]
4.0 [2.3, 14.4]
5.1 [2.6, 20.3]
-
Data are presented as median [Q1, Q3] or number (proportion). *VTLi measurements were performed in a separate population of patients recruited to the BACC study. Detailed characteristics of these patients is provided in Table S2. Abbreviations: BP  blood pressure, eGFR  estimated glomerular filtration rate, CAD  coronary artery disease, ECG  electrocardiogram, MI  myocardial infarction, hs-cTn  high-sensitivity cardiac troponin
Serial measurements of all hs-cTn assays were available in the derivation dataset, but availability of measurements varied among the validation and generalization cohorts (Figure S1). Overall, at time of ED presentation, hs-cTnT Elecsys was the most widely used assay with measurements available in 20,001 patients followed by hs-cTnI Architect in 14,255, hs-cTnI Atellica in 8332, hs-cTnI Access in 6946, hs-cTnI Pathfast in 3246 and hs-cTnI Atellica VTLi in 1088 patients Fig. 2.

Model derivation

Among 18 variables investigated, 9 variables for the single hs-cTn measurement and 8 variables for the serial hs-cTn measurement were selected (Table S6, Fig. 3). Based on these variables, four different learning machines were selected and combined to a super learner into each diagnostic model: For the single hs-cTn diagnostic model multivariable logistic regression with restricted cubic splines, gradient boosting, multivariate adaptive regression splines and elastic net were selected. For the serial hs-cTn diagnostic model multivariable logistic regression with restricted cubic splines, gradient boosting, multivariate adaptive regression splines and random forest were selected. Both diagnostic models provided a better performance compared to models based on hs-cTn alone, models including information on eGFR, or the full models (Figures S2, S3, S4). The machine-learning-based super learner outperformed classical multiple logistic regression for both the single and serial validation models (Figure S3). Specifically, it performed better than any single machine for the single hs-cTn troponin measurements. The diagnostic model using single or serial hs-cTn measurements showed high discriminative accuracies for each evaluated troponin assay (Figure S5).

Model validation

In the validation dataset, the diagnostic model showed a better performance, compared to models based on hs-cTn alone, models including information on eGFR or a model including all offered clinical variables (Figures S2, S3, S4). Observed and predicted risks of MI were for all assays in the derivation data and after calibration in the validation data (Figure S6). When applying the diagnostic model based on a single or a serial hs-cTn measurement in the validation dataset, we observed an increase in AUC and a decrease in logLoss and Brier Score (Figure S5).

Global generalization

In the global generalization dataset, observed and predicted risks of MI were again similar for all assays after re-calibration (Figure S7). The discriminative accuracy using the diagnostic model was high across all cohorts (Figure S5; Table S7). When summarizing the measures across the validation and generalization cohorts, the AUCs were similar for all hs-cTn assays applied (Fig. 2). In detail, the AUCs were 0.95 (95%CI 0.94–0.96) and 0.98 (95%CI 0.97–0.99) for the single and serial hs-cTn diagnostic model using the Access assay, and 0.92 (95%CI 0.89–0.94) and 0.96 (95%CI 0.95–0.98), for the Architect assay, respectively. For the Atellica assay, the AUC was 0.93 (95%CI 0.90–0.97) and 0.96 (95%CI 0.94–0.98), and 0.86 (95%CI 0.82–0.89) and 0.92 (95%CI 0.90–0.95), for the Atellica VTLi point-of-care assay, respectively. For the Elecsys assay, the AUC was 0.89 (95%CI 0.87–0.92) and 0.94 (95%CI 0.92–0.96) and the patient-near Pathfast assay revealed an AUC of 0.95 (95%CI 0.94–0.97) and 0.98 (95%CI 0.97–0.99), respectively.

Clinical application

To illustrate the clinical usability, we calculated the diagnostic measures for each possible MI probability threshold. Across the range of thresholds, we observed a decreasing NPV and sensitivity with increasing MI probability, while PPV, specificity and 30-day mortality continuously increased (Figure S8, Tables S8, S9). As examples, the diagnostic measures to rule-out MI in individuals with a MI probability below 0.5%, below 1% and below 2% are depicted in Table 2 using both diagnostic models with single and serial hs-cTn measurements. When using single hs-cTn measurement and a MI probability of less than 0.5%, we observed very high NPVs of 99.6% or greater. In contrast, when using serial hs-cTn measurement and a MI probability of, e.g., less than 2%, we observed excellent diagnostic measures with NPV values of 99.5% or above and a proportion of at least 60% of the population. Importantly, these values were associated with a low risk of 30-day mortality ranging between 0.6–1.1%.
Table 2
Diagnostic measures of selected MI probability thresholds to rule-out of MI
MI probability < 0.5%
Single hs-cTn measurement model
Serial hs-cTn measurement model
Hs-cTn assay
NPV (95%CI)
Sensitivity (95%CI)
Proportion (95%CI)
30d mortality (95%)
NPV (95%CI)
Sensitivity (95%CI)
Proportion (95%CI)
30d mortality (95%CI)
Access
99.7 (99.4, 99.8)
98.7 (98.3, 99.1)
44.4 (31.7, 57.9)
0.5 (0.2, 1.5)
99.8 (99.6, 99.9)
98.6 (98.0, 99.1)
67.5 (63.3, 71.4)
0.5 (0.2, 1.4)
Architect
99.6 (99.4, 99.8)
99.2 (97.4, 99.7)
30.0 (15.9, 49.4)
0.1 (0.0, 0.5)
99.8 (99.6, 99.9)
98.9 (97.6, 99.5)
59.5 (53.6, 65.1)
0.5 (0.3, 0.9)
Atellica
99.8 (99.6, 99.9)
99.1 (95.4, 99.8)
49.5 (41.5, 57.5)
0.3 (0.1, 0.6)
99.8 (99.6, 99.9)
98.8 (97.3, 99.5)
52.0 (42.7, 61.2)
0.4 (0.2, 0.7)
Atellica VTLi
99.7 (99.3, 100.0)
98.9 (98.2, 99.5)
32.5 (29.5, 35.4)
0.0 (NaN, NaN)
100.0 (NaN, NaN)
100.0 (NaN, NaN)
41.0 (37.8, 44.1)
0.5 (0.1, 0.9)
Elecsys
99.6 (99.2, 99.8)
99.1 (97.9, 99.6)
30.8 (20.8, 42.9)
0.3 (0.1, 1.2)
99.7 (99.3, 99.9)
99.0 (98.1, 99.5)
46.9 (32.3, 62.2)
0.6 (0.2, 1.6)
Pathfast
99.7 (99.4, 100.0)
99.4 (99.0, 99.8)
26.8 (24.3, 29.4)
0.3 (0.0, 0.6)
99.9 (99.7, 100.0)
99.4 (99.0, 99.8)
63.9 (61.1, 66.6)
0.4 (0.0, 0.8)
MI probability < 1%
Single hs-cTn measurement model
Serial hs-cTn measurement model
Hs-cTn assay
NPV (95%CI)
Sensitivity (95%CI)
Proportion (95%CI)
30d mortality (95%)
NPV (95%CI)
Sensitivity (95%CI)
Proportion (95%CI)
30d mortality (95%CI)
Access
99.7 (99.5, 99.8)
98.2 (97.0, 98.9)
51.9 (38.8, 64.8)
0.4 (0.1, 1.3)
99.8 (99.5, 99.9)
98.3 (97.7, 98.8)
72.1 (68.5, 75.5)
0.7 (0.3, 1.7)
Architect
99.6 (99.3, 99.7)
98.5 (97.4, 99.2)
43.8 (34.4, 53.8)
0.2 (0.1, 0.5)
99.7 (99.5, 99.8)
98.6 (97.1, 99.3)
66.3 (58.6, 73.2)
0.7 (0.5, 1.0)
Atellica
99.8 (99.5, 99.9)
98.5 (95.4, 99.6)
54.9 (44.3, 65.2)
0.4 (0.1, 1.0)
99.8 (99.6, 99.9)
98.7 (96.5, 99.6)
59.9 (51.2, 68.0)
0.6 (0.3, 1.0)
Atellica VTLi
99.7 (99.4, 100.0)
98.9 (98.2, 99.5)
35.8 (32.8, 38.8)
0.3 (0.0, 0.6)
100.0 (NaN, NaN)
100.0 (NaN, NaN)
51.5 (48.3, 54.7)
0.6 (0.1, 1.1)
Elecsys
99.6 (99.3, 99.8)
98.5 (96.6, 99.4)
41.0 (31.1, 51.8)
0.4 (0.1, 1.8)
99.7 (99.3, 99.9)
98.7 (97.3, 99.4)
58.3 (46.3, 69.4)
0.7 (0.3, 1.9)
Pathfast
99.4 (98.7, 99.7)
97.6 (96.6, 98.4)
33.6 (7.7, 75.6)
0.3 (0.2, 0.5)
99.7 (99.4, 99.8)
99.2 (98.3, 99.6)
45.5 (11.0, 85.0)
0.5 (0.3, 0.8)
MI probability < 2%
Single hs-cTn measurement model
Serial hs-cTn measurement model
Hs-cTn assay
NPV (95%CI)
Sensitivity (95%CI)
Proportion (95%CI)
30d mortality (95%)
NPV (95%CI)
Sensitivity (95%CI)
Proportion (95%CI)
30d mortality (95%CI)
Access
99.6 (99.3, 99.7)
97.2 (95.3, 98.4)
60.9 (47.9, 72.5)
0.3 (0.1, 1.2)
99.7 (99.5, 99.9)
98.0 (97.4, 98.5)
76.0 (72.0, 79.6)
1.1 (0.5, 2.2)
Architect
99.3 (99.0, 99.5)
97.1 (96.3, 97.8)
54.8 (45.3, 64.0)
0.4 (0.1, 1.3)
99.6 (99.4, 99.8)
98.3 (96.7, 99.1)
71.3 (64.0, 77.6)
0.7 (0.5, 1.0)
Atellica
99.6 (99.4, 99.8)
97.5 (90.2, 99.4)
60.7 (47.3, 72.6)
0.4 (0.2, 0.8)
99.7 (99.5, 99.8)
97.9 (94.6, 99.2)
67.3 (58.6, 74.9)
0.7 (0.5, 1.1)
Atellica VTLi
99.5 (99.0, 99.9)
97.7 (96.8, 98.7)
39.9 (36.8, 43.0)
0.5 (0.1, 1.0)
99.7 (99.3, 100.0)
97.9 (96.7, 99.0)
59.7 (56.5, 62.8)
0.6 (0.1, 1.1)
Elecsys
99.1 (97.7, 99.6)
96.5 (94.6, 97.8)
48.5 (35.1, 62.2)
0.5 (0.2, 1.2)
99.5 (99.3, 99.7)
97.6 (95.1, 98.9)
65.6 (55.3, 74.6)
0.9 (0.4, 2.2)
Pathfast
99.2 (98.8, 99.4)
97.6 (95.0, 98.8)
46.3 (17.0, 78.4)
0.5 (0.3, 0.8)
99.5 (99.1, 99.7)
98.1 (97.6, 98.5)
61.0 (32.9, 83.3)
0.6 (0.4, 0.9)
This table displays the diagnostic performance measures (NPV, proportion of individuals and 30-day mortality) using the MI probability as threshold. This table is based on data from the validation cohort stenocardia as well as the generalization cohorts ADAPT-BSN, ADPs-CH, FASTEST, LUND, RAPID-CPU, SAMIE, SEIGE & SAFETY, STOP-CP and UTROPIA. Abbreviations: MI  myocardial infarction, hs-cTn  high-sensitivity cardiac troponin, NPV  negative predictive value, CI  confidence interval, NaN  not a number

Comparison to standard of care

Comparative analyses using a single hs-cTn measurement approach based on the ESC algorithms versus the ARTEMIS pathway are depicted in Table 3. Using the ARTEMIS pathway and considering an MI probability threshold < 0.5% to identify subjects eligible for direct rule-out of MI, the safety, quantified by NPV and sensitivity, was very high and similar when compared to the direct rule-out approach of the ESC algorithms. Importantly, however, the proportion of patients qualifying for direct and safe rule-out based on a single hs-cTn measurement was increased by factor two–three by our machine-based model, ranging between 30 and 49%, as compared to 14 and 15% using the direct rule-out approach provided by the ESC algorithms. Using an MI probability of > 50% as a direct rule-in criteria, high accuracy, quantified by the PPV and specificity, was achieved. The accuracy and proportions of direct rule-in were similar to the ESC algorithms. Furthermore, the observational zone after a single hs-cTn measurement was reduced for all hs-cTn assays by 10–33% when using the ARTEMIS pathway. For the serial hs-cTn measurement approach, a selection of possible ARTEMIS thresholds to define rule-out and rule-in of MI resulted in overall comparable diagnostic performances when directly compared to the ESC 0/1 h and 0/2 h algorithms (Table S10).
Table 3
Diagnostic performance comparison of the direct rule-out or rule-in approach based on a single hs-cTn measurement of the ESC 0/1 h algorithms and the ARTEMIS diagnostic model
https://static-content.springer.com/image/art%3A10.1007%2Fs00392-023-02206-3/MediaObjects/392_2023_2206_Tab3_HTML.png
This table compares the diagnostic performance to directly rule-out or to rule-in MI using a single hs-cTn measurement with the ESC 0/1 h algorithms and the ARTEMIS diagnostic model. Global and cohort specific imputation of the necessary variables for ARTEMIS, with the exclusion of troponin measurements, was performed. Due to the meta-analytic background of the analyses, the proportions of rule-out, observe and rule-in zone due not sum up to 100%. Using the ARTEMIS model an MI probability < 0.5% to rule-out MI and MI probability > 50% to rule-in MI was used. Abbreviations: MI  myocardial infarction, hs-cTn  high-sensitivity cardiac troponin, NPV  negative predictive value, PPV  positive predictive value

Exemplary clinical use cases

The general workflow and the potential clinical application of the ARTEMIS pathway are displayed in Fig. 3 and Supplementary Appendix (Figure S10). The smart interpretation of cardiac troponin, which can be measured with a large variety of possible hs-cTn assays in ARTEMIS, in combination with other easily available clinical variables may inform the treating physicians in real time about the individual probability of MI in form of a mobile application or, if embedded in the local electronical medical health record system, as a medical decision support system. Hereby, ARTEMIS may guide safe, efficient and immediate medical decision in patients presenting with suspicion of MI.

Discussion

Extending prior work [9], we derived, validated, and generalized a personalized diagnostic model to immediately, accurately, and safely quantify the risk probability of MI. From individual-level data contributed by more than 27,000 patients with suspected acute MI in four continents, nine countries and 14 prospectively established real world cohorts we applied various machine-based learning tools and developed a super learner model resulting in two diagnostic models. Their clinical application allows providers to determine the probability of MI with high diagnostic accuracy. The personalized model (1) works irrespective of which hs-cTn assay is used, (2) integrates the information of important and rapidly available clinical variables, (3) requires neither assay-specific cut-offs nor fixed timing of serial sampling, (4) can be applied after calibration in various clinical settings with widely varying pre-test probabilities and (5) offers a selection of risk probability thresholds (e.g., 0.5%, 1% or 2% MI probability) which allows for safe and immediate discharge in a very high proportion of patients.
While the application of hs-cTn assays improves visibility of even minor myocardial injury and allows for early detection of MI, the clinical management and decision-making became more challenging [4, 13, 15]. Consequently, various assay-specific hs-cTn algorithms have been developed and implemented to efficiently diagnose and triage patients with suspected MI [1618]. Although these algorithms allow for major advances in rapid and safe clinical decision-making, they still rely on inflexible rules for the timing of hs-cTn resampling (1, 2 or 3 h) and apply assay-specific thresholds of mostly very low concentrations and do not account for clinical variables such as age, sex, risk factors, chest pain onset time, and others. In consequence, the assay-specific 0/1 h and 0/2 h or 0/3 h algorithms as suggested by the European Society of Cardiology for example, are not fully implemented in global clinical routine [4].
To accelerate the advantage of hs-cTn usage in clinical routine and enable—in interaction with hs-cTn point-of-care tests—a safe application also in ambulatory settings, we extend the concept of risk probabilities introduced recently [9] towards a highly accurate personalized diagnostic model. As the model was trained using eleven (selected out of an initial 18) clinical variables including time of chest pain onset, time between serial sampling, ECG, age, sex, and cardiovascular risk factors and nearly all hs-cTn tests currently available, it provides the highest possible diagnostic accuracy and allows for rapid and safe decision-making. Both, single and serial sampling models achieve excellent diagnostic accuracy and offer the opportunity to select rule-out thresholds which allow rapid and safe discharge in a high proportion of patients. To achieve the best balance between high safety and high efficacy, a low MI probability threshold (e.g., 0.5%, 1% or 2%) is recommended for rule-out after single or serial testing, respectively. Compared with previous data on the performance of the ESC 0/1 h algorithm reporting a rule-out proportion of 44–57%, the rule-out proportions achieved by the application of the thresholds of the diagnostic models are larger and range, e.g., for a serial rule-out cut-off < 2%, between 60 and 76% [18, 19]. This improvement is most apparent for a single measurement approach, which allows direct rule-out of MI in 30–49% of the overall population compared to 13–15% using the ESC algorithm [1822].
As the model is based on heterogenous global data, it is calibrated for European, Australian, New Zealand, Northern American, and Japanese conditions and, therefore, can be generally applied. The model also integrates two point-of-care hs-cTn assays (Pathfast and Atellica VTLi). When hs-cTn point-of-care assays are used, the ARTEMIS model can be applied in outpatient settings and, therefore, might improve diagnostic accuracy and speed in outpatient care and could reduce the number of hospital admissions.
In general, machine-based learning diagnostic and prediction models need to fulfill high methodological, clinical and regulatory standards before being used by healthcare professionals in clinical practice [23]. A recent report raises 12 critical questions, all of which have been positively addressed by the current algorithm [23]. In particular, the sample size is appropriate, validation has been extensively performed, and the outcome variable is labeled reliable, replicable, and independent.
Prior work already introduced machine-learning concepts to provide an individualized and objective assessment of the likelihood of myocardial infarction [24]. It for the first time presented the concept of machine-based learning to improve the diagnostic accuracy of MI diagnosis and rule-out. Although this work paved the way towards modern diagnostic approaches and performs well in routine clinical practice [25], it relies on only two predefined clinical variables age and sex beyond hs-cTn, and it is restricted to one specific hs-cTnI assay. It further highlights the need for model calibration prior to application in the population, which was limited in this the first concept [25]. The ARTEMIS model had been calibrated for the heterogeneous clinical conditions globally but requires further calibration of the super learner for each clinical setting, in which it will be directly applied. In consequence, the concept and construction of the ARTEMIS model will enable both, the inclusion of any hs-cTn assay entering the market and local calibration to settings in which it will be clinically applied.
The integration of the selected, easily available variables including whatever hs-cTn test available, supports an app- or middleware-guided safe, efficient and immediate medical decision. Whereas the ARTEMIS pathway might be suitable for embedded middleware approaches, which enable the integration into the hospital-based electronic health record system, app-based solutions might be more suitable for ambulatory care or independent emergency settings.
Some limitations should be considered when interpreting the findings. First, the outcome diagnoses of MI were adjudicated in each cohort separately and were not based on a harmonized standard operating procedure. Second, our models were validated to estimate the individual risk of MI in patients with clinically suspected MI. This does not include other acute conditions, that may lead to acute chest pain, such as pulmonary embolism or aortic dissection. Therefore, the estimated MI probabilities must always be considered in the clinical context and should not be used as only basis for decision-making. Finally, our diagnostic models were derived, validated, and generalized using data from multiple prospective, diagnostic studies, but have not been prospectively tested in clinical routine. Therefore, to assess real-world performance not only in the ED but also in other clinical settings (e.g., in ambulatory care or in the preclinical setting in ambulances), prospective clinical trials directly applying the ARTEMIS diagnostic model and comparing against standard of care is of importance.
In conclusion, we developed, validated, and globally applied the easily applicable diagnostic ARTEMIS model considering immediately available variables to estimate the individual risk of MI in patients with suspected MI. The model can be used with most hs-cTn assays currently available and allows for rapid and safe discharge of a very high proportion of patients. Its digital application might improve routine clinical practice globally and enable a personalized diagnostic evaluation of suspected MI.

Acknowledgements

The ARTEMIS study group: Emily Brownlee: Royal Brisbane and Women’s Hospital, Metro North Hospital and Health Service, Brisbane, Queensland, Australia, Kai M. Eggers: Department of Medical Sciences, Uppsala University, Uppsala, Sweden, Gavin Fincher: The Prince Charles Hospital, Metro North Hospital and Health Service, Brisbane, Queensland, Australia, Norbert Frey: Department of Cardiology, Heidelberg University Hospital, Heidelberg, Germany, Niranjan Gaikwad: The Prince Charles Hospital, Metro North Hospital and Health Service, Brisbane, Queensland and School of Clinical Medicine, University of Queensland, Australia, Vinay Gangathimmaiah: Emergency Department, The Townsville Hospital, Townsville, QLD, Australia and School of Medicine, James Cook University, Australia, Emma Hall: Department of Emergency Medicine, Gold Coast University Hospital, Gold Coast, QLD, Australia, Paul M. Haller: Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, Christian Hamilton-Craig: The Prince Charles Hospital, Metro North Hospital and Health Service, Brisbane, Queensland, Faculty of Medicine, University of Queensland and School of Medicine, Griffith University, Sunshine Coast, QLD, Australia, Rebecca Hancock: Emergency Department, The Townsville Hospital, Townsville, QLD, Australia, Andrew Hobbins-King: The Sunshine Coast Hospital, Caloundra, Queensland and School of Medicine, Griffith University, Gold Coast, QLD, Australia, Gerben Keijzers: Department of Emergency Medicine, Gold Coast University Hospital, Gold Coast, QLD, Australia, School of Medicine, Griffith University, Gold Coast, QLD, Australia and Faculty of Health Sciences and Medicine, Bond University, Gold Coast, QLD, Australia, Maryam Khorramshahi Bayat: The Prince Charles Hospital, Metro North Hospital and Health Service, Brisbane, Queensland and School of Clinical Medicine, University of Queensland, Australia, Georgios Koliopanos: Cardio-CARE, Medizincampus Davos, Davos, Switzerland, Jonas Lehmacher: Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, Lina Ljung: Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm, Sweden, Troy Madsen: Department of Emergency Medicine, University of Utah, Ehsan Mahmoodi: The Prince Charles Hospital, Metro North Hospital and Health Service, Brisbane, Queensland, School of Clinical Medicine, University of Queensland and Faculty of Health Sciences and Medicine, Bond University, Gold Coast, QLD, Australia, Ellyse McCormick: Royal Brisbane and Women’s Hospital, Metro North Hospital and Health Service, Brisbane, Queensland, Australia, Bryn Mumma: Department of Emergency Medicine, University of California-Davis, Richard Nowak: Department of Emergency Medicine, Henry Ford Health, Siegfried Perez: Logan Hospital, Metro South Hospital and Health Service, Brisbane, Queensland, Australia, Vazhma Qaderi: Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, Isuru Ranasinghe: The Prince Charles Hospital, Metro North Hospital and Health Service, Brisbane, Queensland and School of Clinical Medicine, University of Queensland, Australia, Alina Schock: Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, Nils A. Sörensen: Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, Andrew Staib: Princess Alexandra Hospital, Metro South Hospital and Health Service, Brisbane, Queensland and School of Clinical Medicine, University of Queensland, Australia, Laura Stephensen: Royal Brisbane and Women’s Hospital, Metro North Hospital and Health Service, Brisbane, Queensland and School of Public Health and Social Work, Queensland University of Technology, Michael Weaver: University of Florida College of Nursing, R. Gentry Wilkerson: Department of Emergency Medicine, University of Maryland School of Medicine, and Anna Zournazi: Pathology Queensland, Australia.

Declarations

Conflict of interest

SB receives fundings from Abbott Diagnostics, Bayer, SIEMENS, Amgen and NOVARTIS as well as honoraria for lectures and/or chairs from Abbott, Abbott Diagnostics,, AMGEN, Astra Zeneca, Bayer, Boehringer Ingelheim, BMS (Bristol Meyer Squib), Daiichi Sankyo, LumiraDx, NOVARTIS and Thermo Fisher. SB is a member of advisory boards and consultant of Thermo Fisher. JTN, RT, FO, TZ, AZ and SB are co-founders and shareholders of the ART-EMIS Hamburg GmbH, which holds an international patent application on the use of a computing device to estimate the probability of myocardial infarction (Publication Numbers WO2022043229A1, TW202219980A). JTN reports speaker honoraria/consulting honoraria from PHC, Roche and Siemens. RT reports research support from the Kühne Foundation, the Swiss National Science Foundation (Grant No P300PB_167803), the Swiss Heart Foundation, the Swiss Society of Cardiology and speaker honoraria/consulting honoraria from Abbott, Amgen, Astra Zeneca, Roche, Siemens, and Singulex. BRA receives research funding/support from Roche Diagnostics, Siemens, and Beckman Coulter. BRA is a consultant for Roche Diagnostics. FSA is a consultant for HyTest Ltd and an associate Editor for Clinical Chemistry. FSA is part of the advisory boards of Werfen, Siemens Healthineers, Qorvo and AWE Medical Group. FSA receives honorarium for speaking at industry conferences of Siemens Healthineers and Beckman Coulter. FSA is PI on Industry Funded Grants (non-salaried) on cardiac biomarkers through Hennepin Healthcare Research Institute for Abbott Diagnostics, Abbott POC, BD, Beckman Coulter, Ortho-Clinical Diagnostics, Roche Diagnostics, Siemens Healthcare, ET Healthcare and Qorvo. RHC is a consultant for and receives funding/support from Roche Diagnostics, Siemens Healthineers, Beckman Coulter Diagnostics, Becton Dickinson and Co, Quidel Corp, and Sphingotec GMBH. LC reports research funding from Siemens, Abbott, and Beckman. EG reports personal fees from Bayer Vital, personal fees from Astra Zeneca, personal fees from Roche Diagnostics, personal fees from Brahms Germany, personal fees from Daiichi Sankyo, personal fees from Lilly Deutschland, outside the submitted work. EG reports participation on a Data Safety. Monitoring Board or Advisory Board at Boehringer Ingelheim and Roche Diagnostics. JG receives grants from Siemen´s Point of Care and Beckman Coulter. KI receives grants from Japanese KAKENHI (grant number JP18K09554). KI reported payment for honoraria for lectures, presentations, speakers bureaus, manuscript writing or educational events from Roche Diagnostics to Fujirebio Inc. PK reports support for this manuscript to his institution from Canadian Institutes of Health Research, Abbott Diagnostics and Roche Diagnostics. PK reports grants for his institution from Abbott Diagnostics, Roche Diagnostics, Randox laboratories, Beckman Coulter, Ortho Clinical Diagnostics and Siemens Healthcare Diagnostics. PK receives consulting fees from Abbott, Beckman Coulter, Roche Diagnostics, Quidel and Siemens Healthcare. PK receives reports honoraria for lectures, presentations, speakers bureaus, manuscript writing or educational events from Beckman Coulter, Roche Diagnostics, Siemens Healthcare and Thermo Fisher Scientific. PK receives support for attending meetings and/or travel from Randox Laboratories ans Roche Diagnostics. McMaster University has filed a patent with PK listed as an inventor in the acute cardiovascular biomarker field, in particular, a patent has been awarded in Europe (EP 3 341 723 B1) on a Method of determining risk of an adverse cardiac event. McMaster University has also filed patents with PK listed as an inventor on Quality Control Materials for Cardiac Troponin Testing and Identifying pregnant women at increased risk for hypertension and future cardiovascular disease. PK reports participation on a Data Safety Monitoring Board or Advisory Board for Roche Diagnostics, Siemens Healthcare Diagnostics, Beckman Coulter and Quidel. BL is a member (unpaid) of Study Group on Biomarkers of the ESC Association for Acute CardioVascular Care. SAM receives research funding/support from Roche Diagnostics, Abbott Laboratories, Ortho Clinical Diagnostics, Creavo Medical Technologies, Siemens, Pathfast, Grifols, Rigel Pharmaceuticals, the Agency for Healthcare Research and Quality, the Patient-Centered Outcomes Research Institute, the National Heart, Lung, and Blood Institute (1 R01 HL118263-01), and the Health Resources and Services Administration (1 H2ARH399760100). Dr Mahler is a consultant for Roche Diagnostics and Amgen and is the chief medical officer for Impathiq Inc. NLM reported grants from British Heart Foundation to his institution (CH/F/21/90010, RG/20/10/34966, RE/18/5/34216). NLM has received honoraria or consultancy from Abbott Diagnostics, Roche Diagnostics, Siemens Healthineers, and LumiraDx. NLM reports participation on an Advisory Board of LumiraDx, Roche Diagnostics and Siemens Healthineers. NLM is supported by a Chair Award, Programme Grant, Research Excellence Award (CH/F/21/90010, RG/20/10/34966, RE/18/5/34216) from the British Heart Foundation. JWP has received non-directed funds from Abbott Diagnostics, Roche, Siemens within the last 5 years and consulted for Abbott. CJP receives Project grants from the Health Research Council of New Zealand and from the Heart Foundation of New Zealand. He is PI on grants hosted by University of Otago. CJP received project grant from the Ministry of Business, Innovation and Employment, New Zealand. CJP is inventor on patents (granted and filed) for the diagnosis of acute coronary syndromes. CJP is CSO at Upstream Medical Technologies. CJP reported research support from Upstream Medical Technologies and from Biovendor R&D. AMR reports speaker honoraria/advisory board fees and research grants in kind and/or cash funding from Roche Diagnostics, Astra Zeneca, Abbott Laboratories, Novartis, NovoNordisk, Thermo Fisher, Critical Diagnostics, Sphingotec, Medtronic and Boston Scientific. AMR reports grants from National Medical Council of Singapore and NovoNordisk research grants. He has received publicly contestable funding from the New Zealand Health Research Council, NZ Heart Foundation and the National Medical research Council of Singapore. AMR reports personal fees from Roche Diagnostics, Novartis and Roche Diagnostics. AMR reports participation on a Data Safety Monitoring Board or Advisory Board in the Pontiac 2 trial and STAREE Trial. YS has previously served on Advisory Boards for Roche Diagnostics and Abbott Diagnostics. YS has also been a speaker for Abbott Diagnostics. WP reported research grants and consulting fees to his institution from Siemens Healthineers. MPT received Funding for clinical research from Abbott, Alere, Beckman, Radiometer and Roche (to his institution). MPT received payment for speaking from Abbott, Alere, and Roche as well as Consulting fees from Abbott, Roche and Siemens. MPT received payment for participation in advisory boards from Abbott, Radiometer, Roche and Siemens as well as funding for education from Abbott, Alere and Beckman (to his institution). BT receives a project-related grant from German Heart foundation and from the Ernst und Berta Grimmke-Stiftung. RWT received payments to his institution from Health Research Council of NZ, Heart Foundation of NZ, American Regent, Merck and Bayer. RWT receives consulting fees from American Regent, Merck, Bayer and Roche Diagnostics.AW is having a patent on the Clinical Chemistry Score. TZ is supported by the German Centre for Cardiovascular Research (DZHK e.V.) grant numbers 81Z1710101 and 81Z0710102.TZ is supported by EU Horizon 2020 programme and EU ERANet and ERAPreMed Programmes.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Unsere Produktempfehlungen

Neuer Inhalt

Print-Titel

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

Literatur
1.
Zurück zum Zitat Nawar EW, Niska RW, Xu J (2007) National hospital ambulatory medical care survey: 2005 Emergency department summary. Adv Data 386:1–32 Nawar EW, Niska RW, Xu J (2007) National hospital ambulatory medical care survey: 2005 Emergency department summary. Adv Data 386:1–32
3.
Zurück zum Zitat Thygesen K, Alpert JS, Jaffe AS, Chaitman BR, Bax JJ, Morrow DA, White HD, Executive Group on behalf of the Joint European Society of Cardiology /American College of Cardiology /American Heart Association /World Heart Federation Task Force for the Universal Definition of Myocardial I (2018) Fourth universal definition of myocardial infarction. J Am Coll Cardiol. https://doi.org/10.1016/j.jacc.2018.08.1038CrossRefPubMed Thygesen K, Alpert JS, Jaffe AS, Chaitman BR, Bax JJ, Morrow DA, White HD, Executive Group on behalf of the Joint European Society of Cardiology /American College of Cardiology /American Heart Association /World Heart Federation Task Force for the Universal Definition of Myocardial I (2018) Fourth universal definition of myocardial infarction. J Am Coll Cardiol. https://​doi.​org/​10.​1016/​j.​jacc.​2018.​08.​1038CrossRefPubMed
4.
Zurück zum Zitat Collet JP, Thiele H, Barbato E, Barthelemy O, Bauersachs J, Bhatt DL, Dendale P, Dorobantu M, Edvardsen T, Folliguet T, Gale CP, Gilard M, Jobs A, Juni P, Lambrinou E, Lewis BS, Mehilli J, Meliga E, Merkely B, Mueller C, Roffi M, Rutten FH, Sibbing D, Siontis GCM, Group ESCSD (2021) 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur Heart J 42(14):1289–1367. https://doi.org/10.1093/eurheartj/ehaa575CrossRefPubMed Collet JP, Thiele H, Barbato E, Barthelemy O, Bauersachs J, Bhatt DL, Dendale P, Dorobantu M, Edvardsen T, Folliguet T, Gale CP, Gilard M, Jobs A, Juni P, Lambrinou E, Lewis BS, Mehilli J, Meliga E, Merkely B, Mueller C, Roffi M, Rutten FH, Sibbing D, Siontis GCM, Group ESCSD (2021) 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur Heart J 42(14):1289–1367. https://​doi.​org/​10.​1093/​eurheartj/​ehaa575CrossRefPubMed
5.
Zurück zum Zitat Writing Committee M, Gulati M, Levy PD, Mukherjee D, Amsterdam E, Bhatt DL, Birtcher KK, Blankstein R, Boyd J, Bullock-Palmer RP, Conejo T, Diercks DB, Gentile F, Greenwood JP, Hess EP, Hollenberg SM, Jaber WA, Jneid H, Joglar JA, Morrow DA, O’Connor RE, Ross MA, Shaw LJ (2021) 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guideline for the evaluation and diagnosis of chest pain: a report of the american college of cardiology/american heart association joint committee on clinical practice guidelines. J Am Coll Cardiol 78(22):e187–e285. https://doi.org/10.1016/j.jacc.2021.07.053CrossRef Writing Committee M, Gulati M, Levy PD, Mukherjee D, Amsterdam E, Bhatt DL, Birtcher KK, Blankstein R, Boyd J, Bullock-Palmer RP, Conejo T, Diercks DB, Gentile F, Greenwood JP, Hess EP, Hollenberg SM, Jaber WA, Jneid H, Joglar JA, Morrow DA, O’Connor RE, Ross MA, Shaw LJ (2021) 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guideline for the evaluation and diagnosis of chest pain: a report of the american college of cardiology/american heart association joint committee on clinical practice guidelines. J Am Coll Cardiol 78(22):e187–e285. https://​doi.​org/​10.​1016/​j.​jacc.​2021.​07.​053CrossRef
6.
Zurück zum Zitat Sandoval Y, Apple FS, Mahler SA, Body R, Collinson PO, Jaffe AS, International Federation of Clinical C, Laboratory Medicine Committee on the Clinical Application of Cardiac B (2022) High-Sensitivity cardiac Troponin and the 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guidelines for the evaluation and diagnosis of acute chest pain. Circulation 146(7):569–581. https://doi.org/10.1161/CIRCULATIONAHA.122.059678CrossRefPubMed Sandoval Y, Apple FS, Mahler SA, Body R, Collinson PO, Jaffe AS, International Federation of Clinical C, Laboratory Medicine Committee on the Clinical Application of Cardiac B (2022) High-Sensitivity cardiac Troponin and the 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guidelines for the evaluation and diagnosis of acute chest pain. Circulation 146(7):569–581. https://​doi.​org/​10.​1161/​CIRCULATIONAHA.​122.​059678CrossRefPubMed
7.
Zurück zum Zitat Writing C, Kontos MC, de Lemos JA, Deitelzweig SB, Diercks DB, Gore MO, Hess EP, McCarthy CP, McCord JK, Musey PI Jr, Villines TC, Wright LJ (2022) 2022 ACC expert consensus decision pathway on the evaluation and disposition of acute chest pain in the emergency department: a report of the American college of cardiology solution set oversight committee. J Am Coll Cardiol. https://doi.org/10.1016/j.jacc.2022.08.750CrossRef Writing C, Kontos MC, de Lemos JA, Deitelzweig SB, Diercks DB, Gore MO, Hess EP, McCarthy CP, McCord JK, Musey PI Jr, Villines TC, Wright LJ (2022) 2022 ACC expert consensus decision pathway on the evaluation and disposition of acute chest pain in the emergency department: a report of the American college of cardiology solution set oversight committee. J Am Coll Cardiol. https://​doi.​org/​10.​1016/​j.​jacc.​2022.​08.​750CrossRef
8.
Zurück zum Zitat Thygesen K, Mair J, Giannitsis E, Mueller C, Lindahl B, Blankenberg S, Huber K, Plebani M, Biasucci LM, Tubaro M, Collinson P, Venge P, Hasin Y, Galvani M, Koenig W, Hamm C, Alpert JS, Katus H, Jaffe AS, Study Group on Biomarkers in Cardiology of ESCWGoACC (2012) How to use high-sensitivity cardiac troponins in acute cardiac care. Eur Heart J 33(18):2252–2257. https://doi.org/10.1093/eurheartj/ehs154CrossRefPubMed Thygesen K, Mair J, Giannitsis E, Mueller C, Lindahl B, Blankenberg S, Huber K, Plebani M, Biasucci LM, Tubaro M, Collinson P, Venge P, Hasin Y, Galvani M, Koenig W, Hamm C, Alpert JS, Katus H, Jaffe AS, Study Group on Biomarkers in Cardiology of ESCWGoACC (2012) How to use high-sensitivity cardiac troponins in acute cardiac care. Eur Heart J 33(18):2252–2257. https://​doi.​org/​10.​1093/​eurheartj/​ehs154CrossRefPubMed
9.
Zurück zum Zitat Neumann JT, Twerenbold R, Ojeda F, Sorensen NA, Chapman AR, Shah ASV, Anand A, Boeddinghaus J, Nestelberger T, Badertscher P, Mokhtari A, Pickering JW, Troughton RW, Greenslade J, Parsonage W, Mueller-Hennessen M, Gori T, Jernberg T, Morris N, Liebetrau C, Hamm C, Katus HA, Munzel T, Landmesser U, Salomaa V, Iacoviello L, Ferrario MM, Giampaoli S, Kee F, Thorand B, Peters A, Borchini R, Jorgensen T, Soderberg S, Sans S, Tunstall-Pedoe H, Kuulasmaa K, Renne T, Lackner KJ, Worster A, Body R, Ekelund U, Kavsak PA, Keller T, Lindahl B, Wild P, Giannitsis E, Than M, Cullen LA, Mills NL, Mueller C, Zeller T, Westermann D, Blankenberg S (2019) Application of high-sensitivity troponin in suspected myocardial infarction. N Engl J Med 380(26):2529–2540. https://doi.org/10.1056/NEJMoa1803377CrossRefPubMed Neumann JT, Twerenbold R, Ojeda F, Sorensen NA, Chapman AR, Shah ASV, Anand A, Boeddinghaus J, Nestelberger T, Badertscher P, Mokhtari A, Pickering JW, Troughton RW, Greenslade J, Parsonage W, Mueller-Hennessen M, Gori T, Jernberg T, Morris N, Liebetrau C, Hamm C, Katus HA, Munzel T, Landmesser U, Salomaa V, Iacoviello L, Ferrario MM, Giampaoli S, Kee F, Thorand B, Peters A, Borchini R, Jorgensen T, Soderberg S, Sans S, Tunstall-Pedoe H, Kuulasmaa K, Renne T, Lackner KJ, Worster A, Body R, Ekelund U, Kavsak PA, Keller T, Lindahl B, Wild P, Giannitsis E, Than M, Cullen LA, Mills NL, Mueller C, Zeller T, Westermann D, Blankenberg S (2019) Application of high-sensitivity troponin in suspected myocardial infarction. N Engl J Med 380(26):2529–2540. https://​doi.​org/​10.​1056/​NEJMoa1803377CrossRefPubMed
10.
Zurück zum Zitat Neumann JT, Sörensen NA, Schwemer T, Ojeda F, Bourry R, Sciacca V, Schaefer S, Waldeyer C, Sinning C, Renné T, Than M, Parsonage W, Wildi K, Makarova N, Schnabel RB, Landmesser U, Mueller C, Cullen L, Greenslade J, Zeller T, Blankenberg S, Karakas M, Westermann D (2016) Diagnosis of myocardial infarction using a high-sensitivity troponin I 1-hour algorithm. JAMA Cardiol 1(4):397–404. https://doi.org/10.1001/jamacardio.2016.0695CrossRefPubMed Neumann JT, Sörensen NA, Schwemer T, Ojeda F, Bourry R, Sciacca V, Schaefer S, Waldeyer C, Sinning C, Renné T, Than M, Parsonage W, Wildi K, Makarova N, Schnabel RB, Landmesser U, Mueller C, Cullen L, Greenslade J, Zeller T, Blankenberg S, Karakas M, Westermann D (2016) Diagnosis of myocardial infarction using a high-sensitivity troponin I 1-hour algorithm. JAMA Cardiol 1(4):397–404. https://​doi.​org/​10.​1001/​jamacardio.​2016.​0695CrossRefPubMed
11.
Zurück zum Zitat Neumann JT, Sörensen NA, Ojeda F, Schwemer T, Lehmacher J, Gönner S, Jarsetz N, Keller T, Schaefer S, Renné T, Landmesser U, Clemmensen P, Makarova N, Schnabel RB, Zeller T, Karakas M, Pickering JW, Than M, Parsonage W, Greenslade J, Cullen L, Westermann D, Blankenberg S (2017) Immediate rule-out of acute myocardial infarction using electrocardiogram and baseline high-sensitivity troponin I. Clin Chem 63(1):394–402. https://doi.org/10.1373/clinchem.2016.262659CrossRefPubMed Neumann JT, Sörensen NA, Ojeda F, Schwemer T, Lehmacher J, Gönner S, Jarsetz N, Keller T, Schaefer S, Renné T, Landmesser U, Clemmensen P, Makarova N, Schnabel RB, Zeller T, Karakas M, Pickering JW, Than M, Parsonage W, Greenslade J, Cullen L, Westermann D, Blankenberg S (2017) Immediate rule-out of acute myocardial infarction using electrocardiogram and baseline high-sensitivity troponin I. Clin Chem 63(1):394–402. https://​doi.​org/​10.​1373/​clinchem.​2016.​262659CrossRefPubMed
12.
Zurück zum Zitat Keller T, Zeller T, Ojeda F, Tzikas S, Lillpopp L, Sinning C, Wild P, Genth-Zotz S, Warnholtz A, Giannitsis E, Möckel M, Bickel C, Peetz D, Lackner K, Baldus S, Münzel T, Blankenberg S (2011) Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction. JAMA 306(24):2684–2693. https://doi.org/10.1001/jama.2011.1896CrossRefPubMed Keller T, Zeller T, Ojeda F, Tzikas S, Lillpopp L, Sinning C, Wild P, Genth-Zotz S, Warnholtz A, Giannitsis E, Möckel M, Bickel C, Peetz D, Lackner K, Baldus S, Münzel T, Blankenberg S (2011) Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction. JAMA 306(24):2684–2693. https://​doi.​org/​10.​1001/​jama.​2011.​1896CrossRefPubMed
13.
Zurück zum Zitat Keller T, Zeller T, Peetz D, Tzikas S, Roth A, Czyz E, Bickel C, Baldus S, Warnholtz A, Frohlich M, Sinning CR, Eleftheriadis MS, Wild PS, Schnabel RB, Lubos E, Jachmann N, Genth-Zotz S, Post F, Nicaud V, Tiret L, Lackner KJ, Munzel TF, Blankenberg S (2009) Sensitive troponin I assay in early diagnosis of acute myocardial infarction. N Engl J Med 361(9):868–877CrossRefPubMed Keller T, Zeller T, Peetz D, Tzikas S, Roth A, Czyz E, Bickel C, Baldus S, Warnholtz A, Frohlich M, Sinning CR, Eleftheriadis MS, Wild PS, Schnabel RB, Lubos E, Jachmann N, Genth-Zotz S, Post F, Nicaud V, Tiret L, Lackner KJ, Munzel TF, Blankenberg S (2009) Sensitive troponin I assay in early diagnosis of acute myocardial infarction. N Engl J Med 361(9):868–877CrossRefPubMed
14.
Zurück zum Zitat R-Core-Team (2013) R: A language and environment for statistical computing. Foundation for Statistical Computing, Vienna, Austria R-Core-Team (2013) R: A language and environment for statistical computing. Foundation for Statistical Computing, Vienna, Austria
15.
Zurück zum Zitat Reichlin T, Hochholzer W, Bassetti S, Steuer S, Stelzig C, Hartwiger S, Biedert S, Schaub N, Buerge C, Potocki M, Noveanu M, Breidthardt T, Twerenbold R, Winkler K, Bingisser R, Mueller C (2009) Early diagnosis of myocardial infarction with sensitive cardiac troponin assays. N Engl J Med 361:858–867. https://doi.org/10.1056/NEJMoa0900428CrossRefPubMed Reichlin T, Hochholzer W, Bassetti S, Steuer S, Stelzig C, Hartwiger S, Biedert S, Schaub N, Buerge C, Potocki M, Noveanu M, Breidthardt T, Twerenbold R, Winkler K, Bingisser R, Mueller C (2009) Early diagnosis of myocardial infarction with sensitive cardiac troponin assays. N Engl J Med 361:858–867. https://​doi.​org/​10.​1056/​NEJMoa0900428CrossRefPubMed
17.
Zurück zum Zitat Shah ASV, Anand A, Strachan FE, Ferry AV, Lee KK, Chapman AR, Sandeman D, Stables CL, Adamson PD, Andrews JPM, Anwar MS, Hung J, Moss AJ, O’Brien R, Berry C, Findlay I, Walker S, Cruickshank A, Reid A, Gray A, Collinson PO, Apple FS, McAllister DA, Maguire D, Fox KAA, Newby DE, Tuck C, Harkess R, Parker RA, Keerie C, Weir CJ, Mills NL, High SI (2018) High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial. Lancet 392(10151):919–928. https://doi.org/10.1016/S0140-6736(18)31923-8CrossRefPubMedPubMedCentral Shah ASV, Anand A, Strachan FE, Ferry AV, Lee KK, Chapman AR, Sandeman D, Stables CL, Adamson PD, Andrews JPM, Anwar MS, Hung J, Moss AJ, O’Brien R, Berry C, Findlay I, Walker S, Cruickshank A, Reid A, Gray A, Collinson PO, Apple FS, McAllister DA, Maguire D, Fox KAA, Newby DE, Tuck C, Harkess R, Parker RA, Keerie C, Weir CJ, Mills NL, High SI (2018) High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial. Lancet 392(10151):919–928. https://​doi.​org/​10.​1016/​S0140-6736(18)31923-8CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Twerenbold R, Neumann JT, Sorensen NA, Ojeda F, Karakas M, Boeddinghaus J, Nestelberger T, Badertscher P, Rubini Gimenez M, Puelacher C, Wildi K, Kozhuharov N, Breitenbuecher D, Biskup E, du Fay de Lavallaz J, Flores D, Wussler D, Miro O, Martin Sanchez FJ, Morawiec B, Parenica J, Geigy N, Keller DI, Zeller T, Reichlin T, Blankenberg S, Westermann D, Mueller C (2018) Prospective validation of the 0/1-h algorithm for early diagnosis of myocardial infarction. J Am Coll Cardiol 72 (6):620-632. https://doi.org/10.1016/j.jacc.2018.05.040 Twerenbold R, Neumann JT, Sorensen NA, Ojeda F, Karakas M, Boeddinghaus J, Nestelberger T, Badertscher P, Rubini Gimenez M, Puelacher C, Wildi K, Kozhuharov N, Breitenbuecher D, Biskup E, du Fay de Lavallaz J, Flores D, Wussler D, Miro O, Martin Sanchez FJ, Morawiec B, Parenica J, Geigy N, Keller DI, Zeller T, Reichlin T, Blankenberg S, Westermann D, Mueller C (2018) Prospective validation of the 0/1-h algorithm for early diagnosis of myocardial infarction. J Am Coll Cardiol 72 (6):620-632. https://​doi.​org/​10.​1016/​j.​jacc.​2018.​05.​040
19.
Zurück zum Zitat Chiang CH, Chiang CH, Pickering JW, Stoyanov KM, Chew DP, Neumann JT, Ojeda F, Sorensen NA, Su KY, Kavsak P, Worster A, Inoue K, Johannessen TR, Atar D, Amann M, Hochholzer W, Mokhtari A, Ekelund U, Twerenbold R, Mueller C, Bahrmann P, Buttinger N, Dooley M, Ruangsomboon O, Nowak RM, DeFilippi CR, Peacock WF, Neilan TG, Liu MA, Hsu WT, Lee GH, Tang PU, Ma KS, Westermann D, Blankenberg S, Giannitsis E, Than MP, Lee CC (2022) Performance of the european society of cardiology 0/1-hour, 0/2-hour, and 0/3-hour algorithms for rapid triage of acute myocardial infarction : an international collaborative meta-analysis. Ann Intern Med 175(1):101–113. https://doi.org/10.7326/M21-1499CrossRefPubMed Chiang CH, Chiang CH, Pickering JW, Stoyanov KM, Chew DP, Neumann JT, Ojeda F, Sorensen NA, Su KY, Kavsak P, Worster A, Inoue K, Johannessen TR, Atar D, Amann M, Hochholzer W, Mokhtari A, Ekelund U, Twerenbold R, Mueller C, Bahrmann P, Buttinger N, Dooley M, Ruangsomboon O, Nowak RM, DeFilippi CR, Peacock WF, Neilan TG, Liu MA, Hsu WT, Lee GH, Tang PU, Ma KS, Westermann D, Blankenberg S, Giannitsis E, Than MP, Lee CC (2022) Performance of the european society of cardiology 0/1-hour, 0/2-hour, and 0/3-hour algorithms for rapid triage of acute myocardial infarction : an international collaborative meta-analysis. Ann Intern Med 175(1):101–113. https://​doi.​org/​10.​7326/​M21-1499CrossRefPubMed
20.
Zurück zum Zitat Boeddinghaus J, Twerenbold R, Nestelberger T, Badertscher P, Wildi K, Puelacher C, du Fay de Lavallaz J, Keser E, Rubini Gimenez M, Wussler D, Kozhuharov N, Rentsch K, Miro O, Martin-Sanchez FJ, Morawiec B, Stefanelli S, Geigy N, Keller DI, Reichlin T, Mueller C, Investigators A (2018) Clinical validation of a novel high-sensitivity cardiac Troponin I assay for early diagnosis of acute myocardial infarction. Clin Chem 64 (9):1347-1360. https://doi.org/10.1373/clinchem.2018.286906 Boeddinghaus J, Twerenbold R, Nestelberger T, Badertscher P, Wildi K, Puelacher C, du Fay de Lavallaz J, Keser E, Rubini Gimenez M, Wussler D, Kozhuharov N, Rentsch K, Miro O, Martin-Sanchez FJ, Morawiec B, Stefanelli S, Geigy N, Keller DI, Reichlin T, Mueller C, Investigators A (2018) Clinical validation of a novel high-sensitivity cardiac Troponin I assay for early diagnosis of acute myocardial infarction. Clin Chem 64 (9):1347-1360. https://​doi.​org/​10.​1373/​clinchem.​2018.​286906
21.
Zurück zum Zitat Boeddinghaus J, Nestelberger T, Twerenbold R, Koechlin L, Meier M, Troester V, Wussler D, Badertscher P, Wildi K, Puelacher C, du Fay de Lavallaz J, Rubini Gimenez M, Zimmermann T, Hafner B, Potlukova E, Miro O, Martin-Sanchez FJ, Keller DI, Reichlin T, Mueller C, investigators A (2019) High-sensitivity cardiac Troponin I assay for early diagnosis of acute myocardial infarction. Clin Chem 65 (7):893-904. https://doi.org/10.1373/clinchem.2018.300061 Boeddinghaus J, Nestelberger T, Twerenbold R, Koechlin L, Meier M, Troester V, Wussler D, Badertscher P, Wildi K, Puelacher C, du Fay de Lavallaz J, Rubini Gimenez M, Zimmermann T, Hafner B, Potlukova E, Miro O, Martin-Sanchez FJ, Keller DI, Reichlin T, Mueller C, investigators A (2019) High-sensitivity cardiac Troponin I assay for early diagnosis of acute myocardial infarction. Clin Chem 65 (7):893-904. https://​doi.​org/​10.​1373/​clinchem.​2018.​300061
24.
Zurück zum Zitat Than MP, Pickering JW, Sandoval Y, Shah ASV, Tsanas A, Apple FS, Blankenberg S, Cullen L, Mueller C, Neumann JT, Twerenbold R, Westermann D, Beshiri A, Mills NL, collaborative MI (2019) Machine learning to predict the likelihood of acute myocardial infarction. Circulation 140:899-909. https://doi.org/10.1161/CIRCULATIONAHA.119.041980 Than MP, Pickering JW, Sandoval Y, Shah ASV, Tsanas A, Apple FS, Blankenberg S, Cullen L, Mueller C, Neumann JT, Twerenbold R, Westermann D, Beshiri A, Mills NL, collaborative MI (2019) Machine learning to predict the likelihood of acute myocardial infarction. Circulation 140:899-909. https://​doi.​org/​10.​1161/​CIRCULATIONAHA.​119.​041980
25.
Metadaten
Titel
Personalized diagnosis in suspected myocardial infarction
verfasst von
Johannes Tobias Neumann
Raphael Twerenbold
Francisco Ojeda
Sally J. Aldous
Brandon R. Allen
Fred S. Apple
Hugo Babel
Robert H. Christenson
Louise Cullen
Eleonora Di Carluccio
Dimitrios Doudesis
Ulf Ekelund
Evangelos Giannitsis
Jaimi Greenslade
Kenji Inoue
Tomas Jernberg
Peter Kavsak
Till Keller
Kuan Ken Lee
Bertil Lindahl
Thiess Lorenz
Simon A. Mahler
Nicholas L. Mills
Arash Mokhtari
William Parsonage
John W. Pickering
Christopher J. Pemberton
Christoph Reich
A. Mark Richards
Yader Sandoval
Martin P. Than
Betül Toprak
Richard W. Troughton
Andrew Worster
Tanja Zeller
Andreas Ziegler
Stefan Blankenberg
the ARTEMIS study group
Publikationsdatum
02.05.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 9/2023
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-023-02206-3

Weitere Artikel der Ausgabe 9/2023

Clinical Research in Cardiology 9/2023 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.