Objectives

The single-energy metal artifact reduction (SEMAR) algorithm effectively reduces metal artifacts in computed tomography (CT). The study aimed to evaluate the effect of the occlusal plane angle on metal artifacts caused by dental implants and zirconia upper structures, and the effectiveness of SEMAR for CT prognostic evaluation.

Methods

Part of a bovine rib was used as the mandibular implant phantom. First, the phantom immersed in a water tank was scanned using CT to obtain the control image under certain conditions. Subsequently, three titanium implant bodies were implanted in a straight line into the phantom, and a zirconia superstructure was attached. CT scans were performed. The CT-reconstructed images were obtained with and without SEMAR processing. Twelve regions of interest (ROIs) were set at the same site on each sagittal image, and the CT values were measured at all the ROIs. The CT values of the ROIs in the control images and those of the ROIs with and without SEMAR were compared.

Results

The variations in the occlusal plane angle during CT imaging negligibly affected the number of regions in which metal artifacts appeared. SEMAR improved the CT value of the trabecular bone, which was affected by metal artifacts.

Conclusion

This study showed that the occlusal plane angle occasionally did not affect the area of metal artifacts caused by dental implants or zirconia upper structures. Other results indicate that SEMAR is effective for accurately evaluating the alveolar bone around the implant body by reducing metal artifacts.
Literatur
1.
Zurück zum Zitat Chen YC, Chen MY, Chen TY. Improving dental implant outcomes: CNN-Based system accurately measures degree of peri-implantitis damage on periapical film. Bioengineering (Basel). 2023;10:640.CrossRefPubMed Chen YC, Chen MY, Chen TY. Improving dental implant outcomes: CNN-Based system accurately measures degree of peri-implantitis damage on periapical film. Bioengineering (Basel). 2023;10:640.CrossRefPubMed
2.
Zurück zum Zitat Sohmura T, Hojoh H, Kusumoto N. A novel method of removing artifacts because of metallic dental restorations in 3-D CT images of jaw bone. Clin Oral Implants Res. 2005;16:728–35.CrossRefPubMed Sohmura T, Hojoh H, Kusumoto N. A novel method of removing artifacts because of metallic dental restorations in 3-D CT images of jaw bone. Clin Oral Implants Res. 2005;16:728–35.CrossRefPubMed
3.
Zurück zum Zitat Almohandes A, Lund H, Carcuac O. Accuracy of bone-level assessments following reconstructive surgical treatment of experimental peri-implantitis. Clin Oral Implants Res. 2022;33:433–40.CrossRefPubMedPubMedCentral Almohandes A, Lund H, Carcuac O. Accuracy of bone-level assessments following reconstructive surgical treatment of experimental peri-implantitis. Clin Oral Implants Res. 2022;33:433–40.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Wagenaar D, van der Graaf ER, van der Schaaf A. Quantitative comparison of commercial and non-commercial metal artifact reduction techniques in computed tomography. PLoS ONE. 2015;10: e0127932.CrossRefPubMedPubMedCentral Wagenaar D, van der Graaf ER, van der Schaaf A. Quantitative comparison of commercial and non-commercial metal artifact reduction techniques in computed tomography. PLoS ONE. 2015;10: e0127932.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Dong J, Hayakawa Y, Kannenberg S. Metal-induced streak artifact reduction using iterative reconstruction algorithms in X-ray computed tomography image of the dentoalveolar region. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115:e63-73.CrossRefPubMed Dong J, Hayakawa Y, Kannenberg S. Metal-induced streak artifact reduction using iterative reconstruction algorithms in X-ray computed tomography image of the dentoalveolar region. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115:e63-73.CrossRefPubMed
7.
Zurück zum Zitat Gondim Teixeira PA, Meyer JB, Baumann C. Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures. Skeletal Radiol. 2014;43:1237–46.CrossRefPubMed Gondim Teixeira PA, Meyer JB, Baumann C. Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures. Skeletal Radiol. 2014;43:1237–46.CrossRefPubMed
8.
Zurück zum Zitat De Crop A, Casselman J, Van Hoof T. Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference? Neuroradiology. 2015;57:841–9.CrossRefPubMed De Crop A, Casselman J, Van Hoof T. Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference? Neuroradiology. 2015;57:841–9.CrossRefPubMed
9.
Zurück zum Zitat Huflage H, Grunz JP, Hackenbroch C. Metal artefact reduction in low-dose computed tomography: benefits of tin prefiltration versus postprocessing of dual-energy datasets over conventional CT imaging. Radiography (Lond). 2022;28:690–6.CrossRefPubMed Huflage H, Grunz JP, Hackenbroch C. Metal artefact reduction in low-dose computed tomography: benefits of tin prefiltration versus postprocessing of dual-energy datasets over conventional CT imaging. Radiography (Lond). 2022;28:690–6.CrossRefPubMed
10.
Zurück zum Zitat Branco D, Kry S, Taylor P, Rong J. Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom. Phys Imaging Radiat Oncol. 2021;17:111–6.CrossRefPubMedPubMedCentral Branco D, Kry S, Taylor P, Rong J. Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom. Phys Imaging Radiat Oncol. 2021;17:111–6.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Chou R, Chi HY, Lin YH. Comparison of quantitative measurements of four manufacturer’s metal artifact reduction techniques for CT imaging with a self-made acrylic phantom. Technol Health Care. 2020;28:273–87.CrossRefPubMedPubMedCentral Chou R, Chi HY, Lin YH. Comparison of quantitative measurements of four manufacturer’s metal artifact reduction techniques for CT imaging with a self-made acrylic phantom. Technol Health Care. 2020;28:273–87.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Demirturk Kocasarac H, Ustaoglu G, Bayrak S. Evaluation of artifacts generated by titanium, zirconium, and titanium-zirconium alloy dental implants on MRI, CT, and CBCT images: a phantom study. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127:535–44.CrossRefPubMed Demirturk Kocasarac H, Ustaoglu G, Bayrak S. Evaluation of artifacts generated by titanium, zirconium, and titanium-zirconium alloy dental implants on MRI, CT, and CBCT images: a phantom study. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127:535–44.CrossRefPubMed
13.
Zurück zum Zitat Smeets R, Schöllchen M, Gauer T. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study. Dentomaxillofac Radiol. 2017;46:20160267.CrossRefPubMedPubMedCentral Smeets R, Schöllchen M, Gauer T. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study. Dentomaxillofac Radiol. 2017;46:20160267.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Lell MM, Meyer E, Kuefner MA. Normalized metal artifact reduction in head and neck computed tomography. Invest Radiol. 2012;47:415–21.CrossRefPubMed Lell MM, Meyer E, Kuefner MA. Normalized metal artifact reduction in head and neck computed tomography. Invest Radiol. 2012;47:415–21.CrossRefPubMed
15.
Zurück zum Zitat Hakim A, Slotboom J, Lieger O. Clinical evaluation of the iterative metal artefact reduction algorithm for postoperative CT examination after maxillofacial surgery. Dentomaxillofac Radiol. 2017;46:20160355.CrossRefPubMedPubMedCentral Hakim A, Slotboom J, Lieger O. Clinical evaluation of the iterative metal artefact reduction algorithm for postoperative CT examination after maxillofacial surgery. Dentomaxillofac Radiol. 2017;46:20160355.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Khaleghi G, Hosntalab M, Sadeghi M. Neural network performance evaluation of simulated and genuine head-and-neck computed tomography images to reduce metal artifacts. J Med Signals Sens. 2022;12:269–77.CrossRefPubMedPubMedCentral Khaleghi G, Hosntalab M, Sadeghi M. Neural network performance evaluation of simulated and genuine head-and-neck computed tomography images to reduce metal artifacts. J Med Signals Sens. 2022;12:269–77.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Zhou P, Zhang C, Gao Z. Evaluation of the quality of CT images acquired with smart metal artifact reduction software. Open Life Sci. 2018;13:155–62.CrossRefPubMedPubMedCentral Zhou P, Zhang C, Gao Z. Evaluation of the quality of CT images acquired with smart metal artifact reduction software. Open Life Sci. 2018;13:155–62.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Hilgenfeld T, Juerchott A, Deisenhofer UK. Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implants-An in vitro study. Clin Oral Implants Res. 2018;29:922–30.CrossRefPubMed Hilgenfeld T, Juerchott A, Deisenhofer UK. Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implants-An in vitro study. Clin Oral Implants Res. 2018;29:922–30.CrossRefPubMed
19.
Zurück zum Zitat Fontenele RC, Nascimento EH, Vasconcelos TV. Magnitude of cone beam CT image artifacts related to zirconium and titanium implants: impact on image quality. Dentomaxillofac Radiol. 2018;47:20180021.CrossRefPubMedPubMedCentral Fontenele RC, Nascimento EH, Vasconcelos TV. Magnitude of cone beam CT image artifacts related to zirconium and titanium implants: impact on image quality. Dentomaxillofac Radiol. 2018;47:20180021.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Vasconcelos TV, Bechara BB, McMahan CA. Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images. Noujeim Oral Surg Oral Med Oral Pathol Oral Radiol. 2017;123:265–72.CrossRefPubMed Vasconcelos TV, Bechara BB, McMahan CA. Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images. Noujeim Oral Surg Oral Med Oral Pathol Oral Radiol. 2017;123:265–72.CrossRefPubMed
21.
Zurück zum Zitat Schulze R. CBCT artefact-burden of zirconia-based as compared to titanium implants for different beam energies: an analytical approach. Sci Rep. 2022;12:15276.ADSCrossRefPubMedPubMedCentral Schulze R. CBCT artefact-burden of zirconia-based as compared to titanium implants for different beam energies: an analytical approach. Sci Rep. 2022;12:15276.ADSCrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Xavier PNI, Vizzotto MB, Arús NA, Tiecher PFDS, Gamba TO, Fontana MP, Beltrão RG, da Silveira HLD. Influence of the presence of dental implants on the accuracy and difficulty level of diagnosis of furcation involvement in molars: an in vitro CBCT study. Clin Oral Implants Res. 2023;34:1385. https://doi.org/10.1111/clr.14182.CrossRefPubMed Xavier PNI, Vizzotto MB, Arús NA, Tiecher PFDS, Gamba TO, Fontana MP, Beltrão RG, da Silveira HLD. Influence of the presence of dental implants on the accuracy and difficulty level of diagnosis of furcation involvement in molars: an in vitro CBCT study. Clin Oral Implants Res. 2023;34:1385. https://​doi.​org/​10.​1111/​clr.​14182.CrossRefPubMed
23.
Zurück zum Zitat Kim YH, Lee C, Han SS, Jeon KJ, Choi YJ, Lee A. Quantitative analysis of metal artifact reduction using the auto-edge counting method in cone-beam computed tomography. Sci Rep. 2020;10:8872.ADSCrossRefPubMedPubMedCentral Kim YH, Lee C, Han SS, Jeon KJ, Choi YJ, Lee A. Quantitative analysis of metal artifact reduction using the auto-edge counting method in cone-beam computed tomography. Sci Rep. 2020;10:8872.ADSCrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Khosravifard A, Saberi BV, Khosravifard N, Motallebi S, Kajan ZD, Ghaffari ME. Application of an auto-edge counting method for quantification of metal artifacts in CBCT images: a multivariate analysis of object position, field of view size, tube voltage, and metal artifact reduction algorithm. Oral Surg Oral Med Oral Pathol Oral Radiol. 2021;132:735–43.CrossRefPubMed Khosravifard A, Saberi BV, Khosravifard N, Motallebi S, Kajan ZD, Ghaffari ME. Application of an auto-edge counting method for quantification of metal artifacts in CBCT images: a multivariate analysis of object position, field of view size, tube voltage, and metal artifact reduction algorithm. Oral Surg Oral Med Oral Pathol Oral Radiol. 2021;132:735–43.CrossRefPubMed
Metadaten
Titel
Phantom study for CT artifacts of dental titanium implants and zirconia upper structures: the effects of occlusal plane angle setting and SEMAR algorithm
verfasst von
Ryoji Kitami
Masahiro Izumi
Motoe Taniguchi
Yusuke Kozai
Takashi Sakurai
Publikationsdatum
26.12.2023
Verlag
Springer Nature Singapore
Erschienen in
Oral Radiology / Ausgabe 2/2024
Print ISSN: 0911-6028
Elektronische ISSN: 1613-9674
DOI
https://doi.org/10.1007/s11282-023-00730-6

Weitere Artikel der Ausgabe 2/2024

Oral Radiology 2/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.