Abstract

Metal-on-metal (MoM) bearing hip arthroplasty saw increasing utilization and peaked in the 1990s and early 2000s. Although the linear and volumetric wear rate for a MoM bearings was lower than its polyethylene counterpart, metal ion particles were found to be approximately 10 × smaller and 500 × higher in quantity compared to polyethylene wear debris. Research into these articulations have demonstrated their relationship to the formation of lymphocyte-mediated adverse local tissue reactions. The work-up for metal particle-associated conditions (metallosis) includes a thorough patient history and physical examination, blood laboratory studies for metal ion concentrations, and advanced imaging studies including magnetic resonance imaging (MRI). The treatment of metallosis and adverse local tissue reactions ranges from close serial observation to extensive debridement and full revision of arthroplasty components, when indicated.
Literatur
1.
Zurück zum Zitat Australian Orthopaedic Association National Joint Replacement Registry (2010) Annual Report 2010. Adelaide, SA, Australia, Australian Orthopaedic Association Australian Orthopaedic Association National Joint Replacement Registry (2010) Annual Report 2010. Adelaide, SA, Australia, Australian Orthopaedic Association
2.
Zurück zum Zitat Bayley J, Scott R (1988) Further observations on metal-backed patellar component failure. Clin Orthop 236:82–87CrossRef Bayley J, Scott R (1988) Further observations on metal-backed patellar component failure. Clin Orthop 236:82–87CrossRef
3.
Zurück zum Zitat Berry D, Barnes C, Scott R, Cabanela M, Poss R (1994) Catastrophic failure of the polyethylene liner of uncemented acetabular components. J Bone Joint Surg Br 76(4):575–578CrossRefPubMed Berry D, Barnes C, Scott R, Cabanela M, Poss R (1994) Catastrophic failure of the polyethylene liner of uncemented acetabular components. J Bone Joint Surg Br 76(4):575–578CrossRefPubMed
4.
Zurück zum Zitat Bolognesi M, Ledford CK (2015) Metal-on-metal total hip arthroplasty: patient evaluation and treatment. J Am Acad Orthop Surg 23(12):724–731CrossRefPubMed Bolognesi M, Ledford CK (2015) Metal-on-metal total hip arthroplasty: patient evaluation and treatment. J Am Acad Orthop Surg 23(12):724–731CrossRefPubMed
5.
Zurück zum Zitat Bozic K, Kurtz S, Lau E, Ong K, Chiu V, Vail T, Rubash H, Berry D (2009) The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg Am 91(7):1614–1620CrossRefPubMed Bozic K, Kurtz S, Lau E, Ong K, Chiu V, Vail T, Rubash H, Berry D (2009) The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg Am 91(7):1614–1620CrossRefPubMed
6.
Zurück zum Zitat Bradberry S, Wilkinson J, Ferner R (2014) Systemic toxicity related to metal hip prostheses. Clin Toxicol 52(8):837–847CrossRef Bradberry S, Wilkinson J, Ferner R (2014) Systemic toxicity related to metal hip prostheses. Clin Toxicol 52(8):837–847CrossRef
7.
Zurück zum Zitat De Martino I, D’Apolito R, Waddell B, McLawhorn A, Sculco P, Sculco T (2017) Early intraprosthetic dislocation in dual-mobility implants: a systematic review. Arthroplast Today 3(3):197–202CrossRefPubMedPubMedCentral De Martino I, D’Apolito R, Waddell B, McLawhorn A, Sculco P, Sculco T (2017) Early intraprosthetic dislocation in dual-mobility implants: a systematic review. Arthroplast Today 3(3):197–202CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Dibra F, Parvataneni H (2016) An unusual presentation of catastrophic failure of hip arthroplasty with a thigh mass. Arthroplast Today 2(2):63–67CrossRefPubMedPubMedCentral Dibra F, Parvataneni H (2016) An unusual presentation of catastrophic failure of hip arthroplasty with a thigh mass. Arthroplast Today 2(2):63–67CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Di Laura A, Quinn P, Panagiotopoulou V, Hothi H, Henckel J, Powell J, Berisha F, Amary F, Mosselmans J, Skinner J, Hart A (2017) The chemical form of metal species released from corroded taper junctions of hip implants: synchrotron analysis of patient tissue. Sci Rep 7(1):10952CrossRefPubMedPubMedCentral Di Laura A, Quinn P, Panagiotopoulou V, Hothi H, Henckel J, Powell J, Berisha F, Amary F, Mosselmans J, Skinner J, Hart A (2017) The chemical form of metal species released from corroded taper junctions of hip implants: synchrotron analysis of patient tissue. Sci Rep 7(1):10952CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Doorn P, Campbell P, Worrall J, Benya P, McKellop H, Amstutz H (1998) Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 42(1):103–111CrossRefPubMed Doorn P, Campbell P, Worrall J, Benya P, McKellop H, Amstutz H (1998) Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 42(1):103–111CrossRefPubMed
13.
Zurück zum Zitat Fabry C, Langlois J, Hamadouche M, Bader R (2016) Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective. Int Orthop 40(5):901–906CrossRefPubMed Fabry C, Langlois J, Hamadouche M, Bader R (2016) Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective. Int Orthop 40(5):901–906CrossRefPubMed
14.
Zurück zum Zitat Firkins P, Tipper J, Saadatzadeh M, Ingham E, Stone M, Farrar R, Fisher J (2001) Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 11:143–157PubMed Firkins P, Tipper J, Saadatzadeh M, Ingham E, Stone M, Farrar R, Fisher J (2001) Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 11:143–157PubMed
15.
Zurück zum Zitat Gillam M, Pratt N, Inacio M, Roughead E, Shakib S, Nicholls S, Graves S (2017) Heart failure after conventional metal-on-metal hip replacements. Acta Orthop 88(1):2–9CrossRefPubMed Gillam M, Pratt N, Inacio M, Roughead E, Shakib S, Nicholls S, Graves S (2017) Heart failure after conventional metal-on-metal hip replacements. Acta Orthop 88(1):2–9CrossRefPubMed
16.
Zurück zum Zitat Hannemann F, Hartmann A, Schmitt J, Lützner J, Seidler A, Campbell P, Delaunay C, Drexler H, Ettema H, García-Cimbrelo E, Huberti H, Knahr K, Kunze J, Langton D, Lauer W, Learmonth I, Lohmann C, Morlock M, Wimmer M, Zagra L, Günther K (2013) European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res 99(3):263–271CrossRefPubMed Hannemann F, Hartmann A, Schmitt J, Lützner J, Seidler A, Campbell P, Delaunay C, Drexler H, Ettema H, García-Cimbrelo E, Huberti H, Knahr K, Kunze J, Langton D, Lauer W, Learmonth I, Lohmann C, Morlock M, Wimmer M, Zagra L, Günther K (2013) European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res 99(3):263–271CrossRefPubMed
17.
Zurück zum Zitat Hannon C, Cotter E, Cooper H, Deirmengian C, Rodriguez J, Urban R, Paprosky W, Jacobs J (2020) Adverse local tissue reaction due to mechanically assisted crevice corrosion presenting as late instability following metal-on-polyethylene total hip arthroplasty. J Arthroplasty 35(9):2666–2670CrossRefPubMed Hannon C, Cotter E, Cooper H, Deirmengian C, Rodriguez J, Urban R, Paprosky W, Jacobs J (2020) Adverse local tissue reaction due to mechanically assisted crevice corrosion presenting as late instability following metal-on-polyethylene total hip arthroplasty. J Arthroplasty 35(9):2666–2670CrossRefPubMed
18.
Zurück zum Zitat Hart A, Hester T, Sinclair K, Powell J, Goodship A, Pele L, Fersht N, Skinner J (2006) The association between metal ions from hip resurfacing and reduced T‑cell counts. J Bone Joint Surg Br 88(4):449–454CrossRefPubMed Hart A, Hester T, Sinclair K, Powell J, Goodship A, Pele L, Fersht N, Skinner J (2006) The association between metal ions from hip resurfacing and reduced T‑cell counts. J Bone Joint Surg Br 88(4):449–454CrossRefPubMed
20.
Zurück zum Zitat Kleeman LT, Bala A, Penrose CT, Seyler TM, Wellman SS, Bolognesi MP (2018) Comparison of postoperative complications following metal-on-metal total hip arthroplasty with other hip bearings in medicare population. J Arthroplasty 33(6):1826–1832CrossRefPubMed Kleeman LT, Bala A, Penrose CT, Seyler TM, Wellman SS, Bolognesi MP (2018) Comparison of postoperative complications following metal-on-metal total hip arthroplasty with other hip bearings in medicare population. J Arthroplasty 33(6):1826–1832CrossRefPubMed
21.
Zurück zum Zitat Koper M, Verdijk R, Bos K (2019) Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal Ion levels. Arthroplast Today 5(1):38–42CrossRefPubMedPubMedCentral Koper M, Verdijk R, Bos K (2019) Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal Ion levels. Arthroplast Today 5(1):38–42CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Kovochich M, Fung ES, Donovan E, Unice K, Paustenbach D, Finley B (2018) Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions. J Biomed Mater Res Part B Appl Biomater 106(3):986–996CrossRef Kovochich M, Fung ES, Donovan E, Unice K, Paustenbach D, Finley B (2018) Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions. J Biomed Mater Res Part B Appl Biomater 106(3):986–996CrossRef
23.
Zurück zum Zitat Liow M, Kwon Y (2017) Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. Int Orthop 41(5):885–892CrossRefPubMed Liow M, Kwon Y (2017) Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. Int Orthop 41(5):885–892CrossRefPubMed
24.
Zurück zum Zitat Lohmann C, Nuechtern J, Willert H, Junk-Jantsch S, Ruether W, Pflueger G (2007) Hypersensitivity reactions in total hip arthroplasty. Orthopedics 30(9):760–761CrossRefPubMed Lohmann C, Nuechtern J, Willert H, Junk-Jantsch S, Ruether W, Pflueger G (2007) Hypersensitivity reactions in total hip arthroplasty. Orthopedics 30(9):760–761CrossRefPubMed
25.
Zurück zum Zitat Malahias M, De Martino I, Gu A, Baral E, Wright T, Sculco P (2019) Complete wear-through of a metal-backed acetabular cup in an ambulatory patient. Arthroplast Today 5(4):394–400CrossRefPubMedPubMedCentral Malahias M, De Martino I, Gu A, Baral E, Wright T, Sculco P (2019) Complete wear-through of a metal-backed acetabular cup in an ambulatory patient. Arthroplast Today 5(4):394–400CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Massin P, Orain V, Philippot R, Farizon F, Fessy M (2012) Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements. Clin Orthop Relat Res 470(7):1932–1940CrossRefPubMed Massin P, Orain V, Philippot R, Farizon F, Fessy M (2012) Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements. Clin Orthop Relat Res 470(7):1932–1940CrossRefPubMed
27.
Zurück zum Zitat McKee GK, Watson-Farrar J (1966) Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br 48(2):245–259CrossRefPubMed McKee GK, Watson-Farrar J (1966) Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br 48(2):245–259CrossRefPubMed
28.
Zurück zum Zitat National Joint Registry for England and Wales (2010) Seventh Annual Report. Hemel Hempstead, Hertfordshire, UK, National Joint Registry Centre National Joint Registry for England and Wales (2010) Seventh Annual Report. Hemel Hempstead, Hertfordshire, UK, National Joint Registry Centre
29.
Zurück zum Zitat Ryu JJ, Shritriya P (2013) Synergistic mechanisms of bio-tribocorrosion in medical implants. In: Yan Y (ed) Bio-tribocorrosion in biomaterials and medical implants. Elsevier, Amsterdam, pp 25–44CrossRef Ryu JJ, Shritriya P (2013) Synergistic mechanisms of bio-tribocorrosion in medical implants. In: Yan Y (ed) Bio-tribocorrosion in biomaterials and medical implants. Elsevier, Amsterdam, pp 25–44CrossRef
30.
Zurück zum Zitat Sabah S, Moon J, Jenkins-Jones S, Morgan C, Currie C, Wilkinson J, Porter M, Captur G, Henckel J, Chaturvedi N, Kay P, Skinner J, Hart A, Manisty C (2018) The risk of cardiac failure following metal-on-metal hip arthroplasty. Bone Joint J 100-B(1):20–27CrossRefPubMedPubMedCentral Sabah S, Moon J, Jenkins-Jones S, Morgan C, Currie C, Wilkinson J, Porter M, Captur G, Henckel J, Chaturvedi N, Kay P, Skinner J, Hart A, Manisty C (2018) The risk of cardiac failure following metal-on-metal hip arthroplasty. Bone Joint J 100-B(1):20–27CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Ude C, Esdaille C, Ogueri K, Ho-Man K, Laurencin S, Nair L, Laurencin C (2021) The mechanism of metallosis after total hip arthroplasty. Regen Eng Transl Med 7(3):247–261CrossRefPubMedPubMedCentral Ude C, Esdaille C, Ogueri K, Ho-Man K, Laurencin S, Nair L, Laurencin C (2021) The mechanism of metallosis after total hip arthroplasty. Regen Eng Transl Med 7(3):247–261CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Urish K, Giori N, Lemons J, Mihalko W, Hallab N (2019) Trunnion corrosion in total hip arthroplasty-basic concepts. Orthop Clin North Am 50(3):281–288CrossRefPubMedPubMedCentral Urish K, Giori N, Lemons J, Mihalko W, Hallab N (2019) Trunnion corrosion in total hip arthroplasty-basic concepts. Orthop Clin North Am 50(3):281–288CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Willert H, Buchhorn G, Fayyazi A, Flury R, Windler M, Köster G, Lohmann C (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28–36CrossRefPubMed Willert H, Buchhorn G, Fayyazi A, Flury R, Windler M, Köster G, Lohmann C (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28–36CrossRefPubMed
34.
Zurück zum Zitat Xia Z, Ricciardi B, Liu Z, von Ruhland C, Ward M, Lord A, Hughes L, Goldring S, Purdue E, Murray D, Perino G (2016) Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty. Nanomedicine Nanotechnol Biol Med 13(3):1205–1217CrossRef Xia Z, Ricciardi B, Liu Z, von Ruhland C, Ward M, Lord A, Hughes L, Goldring S, Purdue E, Murray D, Perino G (2016) Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty. Nanomedicine Nanotechnol Biol Med 13(3):1205–1217CrossRef
Metadaten
Titel
Wear debris in metal-on-metal bearings and modular junctions
What have we learned from the last decades?
verfasst von
Cory Knecht, MD
Landon Polakof, MD
Jonathan Behrens, MD
Stuart B. Goodman, MD PhD
Publikationsdatum
23.02.2023
Verlag
Springer Medizin
Erschienen in
Die Orthopädie / Ausgabe 3/2023
Print ISSN: 2731-7145
Elektronische ISSN: 2731-7153
DOI
https://doi.org/10.1007/s00132-023-04346-w

Weitere Artikel der Ausgabe 3/2023

Die Orthopädie 3/2023 Zur Ausgabe

CME Zertifizierte Fortbildung

Osteoporose: Diagnostik und Behandlung

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.