Abstract

This article reports the autopsy findings of a 76-year-old multimorbid man with polycystic kidney disease. A new replacement left internal jugular vein catheter had been inserted 2 months before death. The patient presented to hospital with nonspecific chest pain and a contained rupture of the descending thoracic aorta was verified by computed tomography (CT) angiography 1 week before death. The rupture was treated with thoracic endovascular aortic repair (TEVAR) and the patient was released from hospital in a stable condition with no sign of bleeding. Due to a permanent catheter malfunction the man was readmitted to hospital 7 days after the stent grafting. Within minutes after CT-assisted catheter replacement, the patient suffered hemoptysis. An emergency bronchoscopy did not identify the source of bleeding. The patient died within 1h following permanent catheter replacement due to massive hemoptysis. Internal examination revealed a penetrating atherosclerotic ulcer with a false aneurysm involving the descending thoracic aorta at the stent graft attachment site that had eroded into the adjacent lower lobe of the left lung. This article reports a case of fatal pulmonary hemorrhage manifesting as massive hemoptysis associated with an endoleak due to aortic stent graft displacement following venous cannulation. It is possible that a left internal jugular vein catheter insertion can be complicated with displacement of the aortic wall in some patients with a thoracic endoprosthesis.
Literatur
2.
Zurück zum Zitat Šteiner I, Povýšil C (2007) Speciální patologie. Galén, Karolinum, Praha Šteiner I, Povýšil C (2007) Speciální patologie. Galén, Karolinum, Praha
3.
Zurück zum Zitat Daye D, Walker TG (2018) Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. Cardiovasc Diagn Ther 8:S138–S156CrossRefPubMedPubMedCentral Daye D, Walker TG (2018) Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. Cardiovasc Diagn Ther 8:S138–S156CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Lang F (2009) Encyclopedia of molecular mechanisms of disease. Springer, Berlin, HeidelbergCrossRef Lang F (2009) Encyclopedia of molecular mechanisms of disease. Springer, Berlin, HeidelbergCrossRef
6.
Zurück zum Zitat Buja LM, Butany J (2016) Cardiovascular pathology. Academic Press, London Buja LM, Butany J (2016) Cardiovascular pathology. Academic Press, London
8.
Zurück zum Zitat Farkaš D, Špak Ľ, Švajdler M, Farkašová Iannaccone S, Sihotský V, Kaťuchová J, Ginelliová A (2015) Traumatic pseudoaneurysm of descendent thoracic aorta solved by aortal stentgraft repair followed by development of fatal aortoesophageal fistula. Soud Lek 60:46–50PubMed Farkaš D, Špak Ľ, Švajdler M, Farkašová Iannaccone S, Sihotský V, Kaťuchová J, Ginelliová A (2015) Traumatic pseudoaneurysm of descendent thoracic aorta solved by aortal stentgraft repair followed by development of fatal aortoesophageal fistula. Soud Lek 60:46–50PubMed
9.
Zurück zum Zitat Hirai S, Hamanaka Y, Mitsui N, Morifuji K, Uegami S (2006) Spontneous rupture of the ascending thoracic aorta resulting in a mimicking pseudoaneurysm. Ann Thorac Cardiovasc Surg 12:223–227PubMed Hirai S, Hamanaka Y, Mitsui N, Morifuji K, Uegami S (2006) Spontneous rupture of the ascending thoracic aorta resulting in a mimicking pseudoaneurysm. Ann Thorac Cardiovasc Surg 12:223–227PubMed
12.
Zurück zum Zitat Jirásek T, Kočka V, Szárszoi O, Pirk J (2013) False aneurysm of the wall a venous graft in a patient with an implanted MGuard type coronary stent: case report and description of the microscopic changes. Cesk Patol 49:137–140PubMed Jirásek T, Kočka V, Szárszoi O, Pirk J (2013) False aneurysm of the wall a venous graft in a patient with an implanted MGuard type coronary stent: case report and description of the microscopic changes. Cesk Patol 49:137–140PubMed
13.
Zurück zum Zitat Farkašová Iannaconne S, Sopková D, Švajdler M, Farkaš D, Mistríková L, Mezencev R (2019) Chronic dissecting aneurysm of ascending aorta with a large intramural thrombus and isolated aortic defects. Cesk Patol 55:115–119 Farkašová Iannaconne S, Sopková D, Švajdler M, Farkaš D, Mistríková L, Mezencev R (2019) Chronic dissecting aneurysm of ascending aorta with a large intramural thrombus and isolated aortic defects. Cesk Patol 55:115–119
15.
18.
Zurück zum Zitat Dieter RS, Dieter RA Jr, Dieter RA III (2019) Diseases of the aorta. Springer, Berlin HeidelbergCrossRef Dieter RS, Dieter RA Jr, Dieter RA III (2019) Diseases of the aorta. Springer, Berlin HeidelbergCrossRef
Metadaten
Titel
Fatal bleeding following left internal jugular vein cannulation associated with type A1 endoleak, false aneurysm and aortobronchopulmonary fistula
verfasst von
Silvia Farkašová Iannaccone
Martin Koščo
Alžbeta Ginelliová
Vladimír Sihotský
Lucia Mistríková
Reinhard Dettmeyer
Daniel Farkaš
Publikationsdatum
15.02.2022
Verlag
Springer Medizin
Erschienen in
Rechtsmedizin / Ausgabe 6/2022
Print ISSN: 0937-9819
Elektronische ISSN: 1434-5196
DOI
https://doi.org/10.1007/s00194-022-00557-1

Weitere Artikel der Ausgabe 6/2022

Rechtsmedizin 6/2022 Zur Ausgabe

Mitteilungen der Deutschen Gesellschaft für Rechtsmedizin

Mitteilungen der Deutschen Gesellschaft für Rechtsmedizin

Neu im Fachgebiet Rechtsmedizin

Assistierter Suizid durch Infusion von Thiopental

Thiopental Originalie

Als Folge des Urteils des Bundesverfassungsgerichts zur Sterbehilfe im Jahr 2020 wurde in den Jahren 2021–2023 eine Reihe (n = 23) von assistierten Suiziden im Landesinstitut für gerichtliche und soziale Medizin Berlin mit jeweils identischen …

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …